Telex C-2002 technical manual Monitor Programming Screen

Page 36

30

Vega’s C-2002

7.11 Monitor Programming Screen

The Monitor Programming Screen is displayed when the MON button is pressed while the display is on the Opening Menu screen.

This screen allows the tone characteristics and whether a monitor tone burst shall automatically go out at the beginning of every offhook condition to be configured. “Auto” is the default and means that a monitor tone burst will go out every time the handset is taken off-hook. “Manual” means that a monitor tone burst will not go out with every off-hook signal.

PROG1 - Go to Monitor Tone Characteristic Selection. PROG2 - Selects between Auto and Manual mode. PROG4 - Return to Opening Menu Screen.

7.11.1 Monitor Characteristic Selection

PROG1 - go to Monitor Frequency Screen. PROG2 - go to Monitor Duration Screen. PROG3 - go to Monitor Level Screen.

PROG4 - Return to Monitor Programming Screen.

Monitor

Auto

Tone

A/M

 

back

PROG1

PROG2

PROG3

PROG4

Mon

2050/040/0

Freq

Dur

Lvl

back

PROG1

PROG2

PROG3

PROG4

7.11.1.1 Monitor Frequency

The Monitor burst normally consists of a 130ms guard tone and is followed by a 40ms monitor tone. In this screen the frequency of the monitor function tone is set. The programmed frequency is displayed as the first of three numbers. The default value is 2050Hz. The Up and Down buttons may be used to increment or decrement the frequency in 1Hz increments. The DTMF keypad may also be used.

PROG1 - resets the frequency to the default value of 2050Hz. PROG2 - decrements the frequency by 1Hz (min freq of 0Hz). PROG3 - increments the frequency by 1Hz (max freq of 3500Hz). PROG4 - return to Monitor Characteristic Screen.

DTMF keypad - may be used to program the frequency.

Mon Freq = 2050

2050H dwn up back

PROG1 PROG2 PROG3 PROG4

7.11.1.2 Monitor Duration

The Monitor burst normally consists of a 130ms guard tone and is followed by a 40ms monitor tone. In this screen the duration of the monitor function tone is set. The programmed duration is displayed in milliseconds as the second of three numbers. The default value is 40ms. The Up and Down buttons may be used to increment or decrement the duration in 10ms increments.

PROG1 - resets the duration to the default value of 40ms. PROG2 - decrements the duration by 10ms (minimum of 40ms). PROG3 - increments the duration by 10ms (maximum of 500ms). PROG4 - return to Monitor Characteristic Screen.

Mon Dur =

40ms

back

40ms

dwn

up

PROG1

PROG2

PROG3

PROG4

7.11.1.3 Monitor Level

The Monitor burst normally consists of a 130ms guard tone at +10dB and is followed by a 40ms monitor tone at 0dB. In this screen the level of the monitor function tone is set. The programmed level is displayed in dB as the third of three numbers. The default value is 0dB. The Up and Down buttons may be used to increment or decrement the level in 1dB increments. The displayed level shall change to reflect the new programming.

PROG1 - resets the level to the default value of 0dB.

PROG2 - decrements the duration by 1dB (minimum of -20dB). PROG3 - increments the duration by 1dB (maximum of 10dB). PROG4 - return to Monitor Characteristic Screen.

Mon

Lvl =

0dB

back

0dB

 

dwn

up

PROG1

PROG2

PROG3

PROG4

Image 36
Contents Model C-2002 Radio Control Console Technical Manual Page Table of Contents Vega’s C-2002 Iii Default Shipping Configuration Introduction Controls and Indicators Common Controls and IndicatorsFront Panel Rear Panel Connections Rear Panel PortsRear Panel Connector Pinouts Rear Panel PinoutOperation Line Setup and Description CrossmuteTwo-Wire/Four-Wire Mode RX Side SettingsSupervisor Function Relay Contact Closure For Local ControlTX Side Settings Transmit MonitorLevel Adjustments Transmit Side AdjustmentsTransmit Monitor Setup RX Level AdjustmentHardware Overview C-2002 ConsoleLine Interface Theory of Operation Microphone Input PathsAudio Output Paths Line Receive Paths Line One/TwoClone Mode Serial Port Power Regulation and Reset Control System Clock GenerationNon-Volatile Memory Eeprom User I/OSetup Mode Tech ModeRestore Defaults? Erasing all settingsOpening Display Menu AUXButton Activated Setup Modes Opening menuLevel Menu Screen Line 1 level adjust Ln1 Min Rx lvl -60dB60dB dwn Back LAM1-S 7sec -10dBm dur lvl S/U backMain level adjust MIC Spkr TX back Main Mic adjustMute Level = -10dB 10db dwn BackSystem Settings Screen Main tone Adjust Dtmf Tone Back Working…Please Wait Target Not Found Dump backDtmf Keypad Enable Tgl Dtmf Hold = 500msec 500ms dwn up back100/100 OffTone Settings Lvl Freq Dur back Dtmf RX Hold Sec Edit NextLevel 10/0/-20 Guard FTn Hold back AUX Input Enabled Tglback AUX Input EnableGrd&Hld Freq= 2175Hz Prev next back Duration 130/200 Guard Hold BackSystem Settings PIN Txdel next back PIN Setup NewTX Delay 300msec New PINAlphanumeric Function-Line Setup L1 F? Back ? F1 BackRampart Line/F-Tone Selection ScreenLine Tone/Local Screen Mute Button Function Tone Parameter Screen Supervisor Enable Alert ProgrammingMonitor Programming Screen Section Parameter Default Programmed Vega’s C-2002 Remote Control Console C-2002 Top Assembly, P.N Schematic Bill of Material, component layoutTechnical Documentation C-2002 Main Board, P/NPage Page Page Page Page Page Page Page PCB ASSY, C-2002 Main Board QTY Type Description Designator Conn SMT 40 PIN Type Description Designator Page BNSFRDCKeypad.sch-1 Fri Mar 22 131105 PCB ASSY, Bnsf RDC Keypad Board Page Page Doug Ehlers Warranty, Service, Repair, and Comments Warranty LimitedFactory Service Center Telex Communications, Inc Specifications Front panel controls