Chapter 1 Ericsson
Configuring Cisco Unity for the Integration
To enter port settings
Step 1 In the Cisco Unity Administrator, go to System > Ports.
Step 2 Select a port in the table.
Step 3 Indicate the settings for the port.
For a hunt group, use the first
Step 4 Type the extension for the port.
Step 5 Repeat Steps 2 through 4 for the remaining ports.
Step 6 Click the Save icon.
Step 7 For the settings to take effect, exit the Cisco Unity software. For more information, see the appendix, “Exiting and Starting the Cisco Unity Software and Server.”
If your phone system uses extension numbers that begin with zero (for example, 0123 or 09876), perform the following procedure.
Note that after the procedure is performed all extension numbers must have the same number of digits. In this case, for example, 0123 and 1234 are both allowed, but 0123 and 234 are not allowed.
To enable extensions beginning with zero
Step 1 On the Cisco Unity server, navigate to the \CommServer\Intlib directory on the drive you installed Cisco Unity.
Step 2 In the Intlib directory, locate the file Ericsson0001.ini.
Step 3 Open the file in a text editor.
Step 4 In the Configuration section of the file, locate the following line:
AllowZeroLeadingExtensions=0
Step 5 Change the final digit to 1, so the line reads:
AllowZeroLeadingExtensions=1
| Ericsson |