TROUBLE SHOOTING

Phone Number Programming

You can program up to 6 Emergency Phone Numbers. When the system is in panic, the control panel will call these phone numbers and announce its status.

The 6 emergency phone numbers include:

-5 voice message phone numbers

-1 Contact ID message phone number

Program the following for Voice Message Phone Numbers

-Phone memory (from 1 to 5), this is where the phone numbers will be stored

-Phone number, up to 29 digits.

-Redial count, this is how many times that phone number will be called, from 1 to 9 times.

-Repeat count, this is how many times the emergency message will be repeated, from 1 to 9 times.

Control Panel

Questions

Why I can’t arm my system?

I cannot arm the system even when no sensor is triggered, and the ARM LED is off.

Solutions

Make sure none of the sensors are triggered. You can check this by the zone LEDs, none of them should blink.

You need to disarm the system again by either entering the password or disarm by keychain remote. Although the ARM LED is off, but the system is not completely disarmed after an alarm was triggered. Refer to page 22 on how to completely disarm a control panel after an alarm has been triggered.

Step

Keys

Function

Description

1

[PROG]

Enter

Enter master password to

 

[MPIN]

Programming

programming mode

 

mode

 

 

 

 

2

[1]

Select phone

 

 

 

number

 

 

 

programming

 

3

[1] to [5]

Enter phone

During emergency, phone

memory 1 will be called first,

 

 

memory

 

 

then phone memory 2, 3, 4, and

 

 

 

5. So phone memory 1 has higher priority.

Note

3 beeps for valid password. 1 long beep for invalid password.

You will hear [Enter phone memory].

Why the ARM LED keeps flashing?

How do I exit programming mode when I’m in the middle of it?

When a sensor is triggered, the alarm sounds instantly even it is not armed, why is that?

That means you have not programmed any emergency phone numbers. For instructions on how to program emergency phone numbers, please see page 10.

You can press the programming button on the side of the unit to quit programming anytime.

You have programmed that sensor in alarm mode, instead of beep mode. Please refer to page 29 for instructions of how to program it back to beep mode.

4 [Phone Enter phone number] number

+[Arm]

5 [1] to [9] Enter Redial

+[Arm] count

6 [1] to [9] Enter Repeat

+[Arm] count

Phone number can be up to 29 digits.**

Redial is the number of times that phone number will be called. Each phone number can have a different redial count, from 1 to 9 times.

Repeat is the number of times that voice emergency message will be played, from 1 to 9 times. It is recommended to set up the repeat time to 5 or more.

You will hear [Enter Redial].

You will hear [Enter Repeat].

You will hear [Phone Accepted] indicating the phone number and its settings have been programmed successfully.

When the alarm is triggered, why the control panel won’t call all the programmed phone numbers? It always stops before calling the last number.

Why the control panel doesn’t beep when a sensor is triggered, while only the zone LED flashes?

The control panel is in armed mode, why activating a sensor will not cause

The control panel will stop calling when it is disarmed by any one of the recipients. Disarm can also be done locally thru the keypad on the control panel by entering a valid password.

You have placed the buzzer mode selector on the side of the control panel to “II”, this will disable the beeping. Placing it to “I” will enable the beeping.

If the triggered sensor is programmed in the Alert Zone (Bypass Zone), alarm will not

**Note:

You may enter a 3-second pause between digits by pressing [Mute] if needed. You may also enter consecutive multiple pause periods. For example, you may enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number (123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be a password to a paging system, or an access code for a phone dialing system.

an alarm, or call any emergency phone number?

sound, and emergency call will not be made if this sensor is triggered. The control panel will only respond when it is disarmed, in alert mode.

10

47

Image 12
Contents Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel 905 Fax 905Email support@skylinkhome.com Home Smart Center Important Safety Instructions Declaration of Conformity EMCContent System ConfigurationOperation Disarming a triggered control panelIntroduction OverviewFCC Information Consumer Information System Configuration Accessories Control Module SW-100Control Module SW-101U UK, SW-101F French, SW-101G German Emergency Dialer AD-433SInstallation Installing the ConsoleInstallation Accessories Trouble Shooting Installation Programming PasswordsChanging Passwords Order to change the password, follow the procedures belowInstallation Trouble Shooting SolutionsPhone Number Programming Control PanelTesting Phone Numbers Home AutomationContact ID Phone number Event TriggerAccount Number Programming Table F Zone LED status for erasing control moduleDeactivating the Digital Dialer OperationErase Control Modules Installing Door / Window Sensors Part 2 Learn signal from Control Panel to Control ModuleTesting Mounting the SensorInstalling Motion Sensor Insert BatteryPart 1 Learn signal from Control Module to Control Panel Table E Zone LED status for learning control moduleControl module command signal Learn Control ModulesAlert Mode OperationAdvanced Programming Erase SensorsMute Learn Sensors ContinueTable C System Status Arming the SystemLearn Sensors Erase Keychain / Keypad Remotes Disarming the systemBefore the siren sounds System is now armedLearn Keychain / Keypad Remotes Disarming a triggered control panelDisarming under Duress To enable alert zone feature, follow the instructions below PanicSystem Failure Phone Line FailureLow Battery It is recommend to enable alert zone ifSensor Failure Control PanelTo enable auto mute feature, follow the instructions below Auto MuteCommunication Receiving the Emergency CallExample To access the control panel away from home Calling in when you are away from homeSystem Armed Alarm Mode Remote Operation by TelephoneBeep / Alarm System Disarmed Alert ModeRemote Phone Operations

ML-001, ML-100 specifications

The SkyLink ML-100 and ML-001 are innovative products in the realm of machine learning and artificial intelligence, designed to simplify the process of deploying and managing machine learning models in various applications. As devices that cater to developers and businesses alike, they bring cutting-edge technologies to the forefront, ensuring a seamless experience for users looking to utilize machine learning effectively.

The SkyLink ML-100 is specifically engineered to provide high-performance capabilities in a compact form factor. One of its main features is the advanced processing unit, which leverages state-of-the-art neural network architectures. This allows the device to handle complex algorithms and process large datasets efficiently. Additionally, the ML-100 is equipped with robust connectivity options, including Wi-Fi, Bluetooth, and support for various IoT protocols, making it an ideal choice for applications in smart homes, industrial automation, and beyond.

On the other hand, the SkyLink ML-001 serves as a versatile platform for developers who wish to train and deploy their machine-learning models. It is designed with a user-friendly interface that supports easy integration with popular programming languages such as Python and R. The ML-001 also boasts an extensive library of pre-built models and algorithms, enabling users to accelerate their development processes. Furthermore, the device comes with advanced data analytics features, providing insightful reports and visualizations that help users understand their model performances better.

Both devices prioritize energy efficiency, ensuring that they can run demanding models without excessive power consumption. They feature adaptive cooling technologies to maintain optimal operating conditions, thereby prolonging device lifespan and enhancing performance stability.

SkyLink incorporates robust security measures into both models, protecting sensitive data and ensuring secure communications. With end-to-end encryption and secure access controls, businesses can rest assured that their data remains confidential.

In conclusion, the SkyLink ML-100 and ML-001 represent significant advancements in machine learning technologies, offering a unique blend of performance, versatility, and security. Whether targeting developers seeking a platform for model deployment or businesses looking for powerful, connected devices, these products stand out in the competitive landscape, providing the tools necessary to harness the full potential of machine learning.