INSTALLATION (ML-100 Only)

HOME AUTOMATION

3. Single flash

Part 1 Learn signal from Control Module to Control Panel

1. Zone 1 Sensor 1

Step

Keys

Function

Description

Note

Triggered

2. Beep___Beep___

Beep___Beep___

............

Note:

- Try to mount the sensors as far away from the floor as possible to avoid

damaging them. Mounting the sensors at a higher position will also result in

better operating range.

1

[PROG]

Enter Program-

 

[MPIN]

ming mode

2

[4]

Select learn

 

 

control module

programming

Enter master

3 beeps for valid

password to

password. 1 long beep

programming

for invalid password.

mode

 

 

After [4] is entered, some

 

zone LEDs will flash or

 

stay off. The zone LEDs

 

represent whether that

 

zone is already occupied

 

by another control

 

module.**See Table E.

- Do not mount the sensor to the exterior of the door / window, always mount the

sensor to the interior side of the door / window to avoid being damaged or

stolen by non-intended users.

Installing Motion Sensor

The motion sensor is most suitable for guarding a large area such as living room, family room, or bedroom. It can also be used to monitor a hallway or stairway.

Insert Battery

3

[1] to [5]

Select control

 

 

module location

 

 

(Max. 5 control

 

 

modules)

4

Activate the

Send signal

 

control module

from control

 

by pressing its

module to

 

learn button

control panel.

 

once quickly.

 

Select the location [1], [2], [3], [4], or [5].

Once the signal is transmitted to the Control Panel, that signal will be stored.

After you have selected the control module location, that zone LED will be on.

You will hear

[Device X Accepted], where “X” is the control module location.

Undo the screw on the back of the motion sensor and remove the battery cover. Connect a 9V alkaline battery to the battery connector. Please note the polarity.

If you are planning to install the motion sensor outdoor, you should reduce the sensitivity by placing the jumper at location “2”.

For indoor application, if you want to reduce the sensitivity, you can change the jumper setting to

“2” as well.

Sensitivity

Jumper Location 1

High Sensitivity

Jumper Location 2

Low Sensitivity

Caution:

Depending on the environment, if you experience a false trigger when the motion sensor is placed outdoors, you should relocate it or even place it indoors. Wind blowing at a tree, or direct sunshine could cause a false trigger. Therefore, if the location at where the motion sensor is mounted could cause a false trigger, you should change the mounting location for such sensor.

ZONE LED

DESCRIPTION

Off

Zone is not occupied by any control module

Flashes once

This zone is occupied by another control module. Programming

 

another remote to this zone will overwrite the previous control

 

module.

Flashes twice

This zone is occupied by a remote. You can still program a control

 

module to this zone, and it will not overwrite the remote you have

 

in this zone.

Flashes once,

This zone is occupied by a remote AND a control module. If you

then twice

program another control module to this zone, it will overwrite the

 

previous control module, but not the remote.

**Table E: Zone LED status for learning control module.

16

41

Image 18
Contents Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel 905 Fax 905Email support@skylinkhome.com Home Smart Center Important Safety Instructions Declaration of Conformity EMCOperation ContentSystem Configuration Disarming a triggered control panelIntroduction OverviewFCC Information Consumer Information System Configuration Control Module SW-101U UK, SW-101F French, SW-101G German AccessoriesControl Module SW-100 Emergency Dialer AD-433SInstallation Installing the ConsoleInstallation Accessories Changing Passwords Trouble Shooting InstallationProgramming Passwords Order to change the password, follow the procedures belowPhone Number Programming Installation Trouble ShootingSolutions Control PanelTesting Phone Numbers Home AutomationContact ID Phone number Event TriggerAccount Number Programming Table F Zone LED status for erasing control moduleDeactivating the Digital Dialer OperationErase Control Modules Testing Installing Door / Window SensorsPart 2 Learn signal from Control Panel to Control Module Mounting the SensorPart 1 Learn signal from Control Module to Control Panel Installing Motion SensorInsert Battery Table E Zone LED status for learning control moduleControl module command signal Learn Control ModulesAdvanced Programming Alert ModeOperation Erase SensorsMute Learn Sensors ContinueTable C System Status Arming the SystemLearn Sensors Before the siren sounds Erase Keychain / Keypad RemotesDisarming the system System is now armedLearn Keychain / Keypad Remotes Disarming a triggered control panelDisarming under Duress System Failure To enable alert zone feature, follow the instructions belowPanic Phone Line FailureSensor Failure Low BatteryIt is recommend to enable alert zone if Control PanelTo enable auto mute feature, follow the instructions below Auto MuteCommunication Receiving the Emergency CallExample System Armed Alarm Mode To access the control panel away from homeCalling in when you are away from home Remote Operation by TelephoneBeep / Alarm System Disarmed Alert ModeRemote Phone Operations

ML-001, ML-100 specifications

The SkyLink ML-100 and ML-001 are innovative products in the realm of machine learning and artificial intelligence, designed to simplify the process of deploying and managing machine learning models in various applications. As devices that cater to developers and businesses alike, they bring cutting-edge technologies to the forefront, ensuring a seamless experience for users looking to utilize machine learning effectively.

The SkyLink ML-100 is specifically engineered to provide high-performance capabilities in a compact form factor. One of its main features is the advanced processing unit, which leverages state-of-the-art neural network architectures. This allows the device to handle complex algorithms and process large datasets efficiently. Additionally, the ML-100 is equipped with robust connectivity options, including Wi-Fi, Bluetooth, and support for various IoT protocols, making it an ideal choice for applications in smart homes, industrial automation, and beyond.

On the other hand, the SkyLink ML-001 serves as a versatile platform for developers who wish to train and deploy their machine-learning models. It is designed with a user-friendly interface that supports easy integration with popular programming languages such as Python and R. The ML-001 also boasts an extensive library of pre-built models and algorithms, enabling users to accelerate their development processes. Furthermore, the device comes with advanced data analytics features, providing insightful reports and visualizations that help users understand their model performances better.

Both devices prioritize energy efficiency, ensuring that they can run demanding models without excessive power consumption. They feature adaptive cooling technologies to maintain optimal operating conditions, thereby prolonging device lifespan and enhancing performance stability.

SkyLink incorporates robust security measures into both models, protecting sensitive data and ensuring secure communications. With end-to-end encryption and secure access controls, businesses can rest assured that their data remains confidential.

In conclusion, the SkyLink ML-100 and ML-001 represent significant advancements in machine learning technologies, offering a unique blend of performance, versatility, and security. Whether targeting developers seeking a platform for model deployment or businesses looking for powerful, connected devices, these products stand out in the competitive landscape, providing the tools necessary to harness the full potential of machine learning.