Digital Pad SettingsProgramming Reference
Extension Port Settings
Parameter | Station Port Class |
|
|
Description | By default, DBS phones are assigned a circuit type, based on |
| whether they are KTELs or SLTs. |
| The circuit type is used with digital pad settings to determine the |
| loss/gain settings for connections to the ISDN. (See “Digital Pad |
| Setting” on page |
| The Port Class parameter is provided in case a specific phone or |
| group of phones needs a unique pad level. |
| For example, an SLT is assigned by default as “circuit type 2.” How- |
| ever, if an SLT in a remote warehouse has inadequate volume levels, |
| the circuit type for the SLT could be changed to 7 (Option 1). Once |
| the SLT is changed to circuit type 7, the pad levels for circuit type 7 |
| could be changed to provide the correct volume setting. |
| Note: Circuit types are also provided for trunk ports. See Figure |
| on page |
|
|
Programming | FF3 |
|
|
Options | This programming parameter will allow you to assign circuit types |
| |
| used with a station port are circuit types 1, 2, 7, or 8. (Circuit types 7 |
| and 8 are used to assign unique PAD levels to circuits that require |
| special volume levels.) |
|
|