Philips DBS-EX23-530 manual Trunk Settings Programming Reference

Page 84

Trunk Settings

Programming Reference

Parameter

ISDN DID Flexible Ringing Assignments

Description

This parameter enables or disables ringing for specific ISDN

 

Inbound DID numbers during Day, Night, Delayed Day and

 

Delayed Night modes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Programming

FF1 9# 5# (0000-9999)# (100-699)# (000000-111111)#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

0=Disable ringing

 

1=Enable ringing

 

Where the entry position determines the ringing as follows:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The default entry is 111000 (day and night ringing enabled, delayed day and delayed night ringing disabled.

4-32

DBS-EX23-530

Revised April 2000

Image 84
Contents Isdn For CPC-EX VersionPage Contents Programming Reference DBS-EX23-530 RevisedList of Figures List of Tables About This Manual OverviewRelated Documents Chapter Title PurposeViii DBS-EX23-530 Revised April Introduction to the Isdn Interface TopicDBS-EX23-530 Revised April Overview Description of the Isdn InterfaceFraming Options Introduction to the Isdn Interface OverviewPre-Installation Requirements Ordering IsdnInformation Needed from CO Comments / Examples Typical Information for CO Comments ExamplesLpic Information Needed from CO Site Information Typical Information for CO Site InformationSpan Item Master Cabinet Span Slave Cabinet Span ESFWhat You Must Purchase DBS EquipmentCSU Equipment Page Installation DBS-EX22-530 Revised April Installation Guidelines GuidelinesHardware Requirements MaximumsGuidelines Installation Trunk Assignments for Single-Cabinet Systems Trunk Assignments for Double-Cabinet Systems System Size Master Slave Trunk Master Cabinet Slave Cabinet NumberTrunk Master Cabinet Slave Cabinet Number Trunk Master Cabinet Slave Cabinet Number Trunk Master Cabinet Slave Cabinet Number Trunk Master Cabinet Slave Cabinet Number Installation Procedures Installing the CSUInstallation Procedures If you’re installing Use this procedureInstallation Installation Procedures Parameter System ConfigurationInstalling an Isdn in a Single Cabinet Attach the Sync Unit to the CPC-EX card Sync Unit installation MDF card installation Distance from the DBS to the CSU To 150 ft 150-450 ft 450-655 ftPins Designation RJ48 Pin DesignationsIsdn cabinet connections, single-cabinet installation Installation Installation Procedures Installation Procedures Installation Installation Procedures Slave Cabinet Quick-Start Programming DBS-EX23-530 Revised April Before You Begin Quick-Start Programming Before You BeginDBS-EX22-530 Issued 10/23/98 Programming Initial Isdn OptionsMinimum Programming Programming Initial Isdn Options Quick-Start ProgrammingQuick-Start Programming Programming Initial Isdn Options =Free run internal clockingDisable PublicNone = Loop startSend as is Determine Type and PlanFF1 9# 4# 5# 5# 3# 0-2# NSF Multiple did Programming =DID data on display=Off Typical Central Office Configurations CO Type 0 4ESSProgramming Reference DBS-EX23-530 Revised April Isdn System Settings Programming Reference Isdn System SettingsSystem Size =T1Clock Settings Isdn System SettingsProgramming Reference=None Isdn System Settings Programming Reference System-Wide Timers Programming Reference System-Wide TimersSystem-Wide Timers Programming Reference 15=Infinite=4 sec =30 sec System-Wide Timers Programming Reference Programming Reference System-Wide Timers Digital Pad Settings Digital Pad Settings Programming ReferenceProgramming Reference Digital Pad Settings SLT Isdn #2Extension Port Settings Digital Pad SettingsProgramming ReferenceTrunk Port Settings Programming ReferenceDigital Pad SettingsMaster and Slave Settings Trunk ConfigurationTrunk Signaling Master and Slave Settings Programming ReferenceAlarm Settings Alarm DescriptionsProgramming Reference Alarm Settings Alarm Description NotificationAlarm Settings Programming Reference Parameter Address FunctionSlip Alarms Alarm Transmission Options =YesAlarm Timers Programming ReferenceAlarm Settings=10 ms Error Counters for FF Alarm Keys Programming Reference Alarm Settings Alarm Settings Programming Reference Alarm Relay Controls =Off Alarm relay does not closeAlarm Settings Programming Reference =Auto Trunk Settings Trunk Settings Programming Reference=Do not reset Programming Reference Trunk Settings Public networkDisable NoneSend as is with Send as is with leadingTrunk Settings Programming Reference =Off Extension Settings Extension Settings Programming ReferenceFF Key Settings Programming Reference FF Key SettingsAlarm Master Isdn Slave Isdn Special Isdn Function Codes Special Isdn Function Codes Programming ReferenceProgramming Reference Special Isdn Function Codes Yellow Appendix a CPC-EX 2.3 Updates New FeaturesSoftware Corrections Port Voice Mail Support via API ProgrammingOff-Hook Voice Announce Ohva via API Small LCD Soft Key Support via APICall Record Ohva via API Special Features UNA TransferSetting Value UNA Call ReversionForwarding to UNA for CO Held Call DBS-2.3-400 DBS Manual Revised April A-9 All Ring Group Private Password FF1 6# 3# NNNN#Terminal Programming Through a Direct Connection ON/OFF #93Terminal Programming Through Disa Additional RAI Access Method Terminal Programming Through Additional RAI Access MethodTerminal Programming Commands Command DescriptionDBS-2.3-400 DBS Manual Revised April A-15 Isdn Upgrade Procedure Isdn Programming FlexibilityName Key Sequence Master Cabinet Set-Up DMS100 Send as isDetermine Type and Plan Slave Cabinet Set-Up DMS-100Typical Central Office Configurations Lucent AT&T 4ESS Lucent AT&T 5ESSNortel NT DMS100 Info Needed from CO Comments examplesTypical Info for CO Comments examples Will exceed the total number of B channels DBS-2.3-400 DBS Manual Revised April A-23 Feature Changes Affected ItemsFF1 2# 2# 7# System Speed Bins 257- 500 Unavailable Index Revised April DBS-EX23-530 Index-iSync cable 2-18, 2-21, 2-23 Sync loss alarm Index-ii DBS-EX23-530 Revised April