Special ISDN Function Codes

Programming Reference

Parameter

Forced Re-synchronization

 

 

Description

Re-synchronizes the DBS ISDN with the public network.

 

Notes:

 

1. Forced re-synchronization disconnects existing calls.

 

2. Before executing this code, you must first enter the program-

 

ming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 6

 

Slave: ON/OFF #95 6

 

 

Options

None. Re-synchronization begins as soon as the code is entered.

 

 

 

 

Parameter

Historical Error Clearance

 

 

Description

Clears the error counters for the following alarms:

 

yellow

 

red

 

framing loss

 

slip rate

 

loss of signal

 

sync loss

 

Note: Before executing this code, you must first enter the pro-

 

gramming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 7

 

Slave: ON/OFF #95 7

 

 

Options

None. The counters are cleared as soon as the code is entered.

 

 

 

 

Parameter

Alarm Relay Clear

 

 

Description

Clears (opens) the alarm relay on the ISDN MDF card.

 

Note: Before executing this code, you must first enter the pro-

 

gramming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 8

 

Slave: ON/OFF #95 8

 

 

Options

None. The relay is cleared as soon as the code is entered.

 

 

 

4-38

DBS-EX23-530

Revised April 2000

Image 90
Contents Isdn For CPC-EX VersionPage Contents Programming Reference DBS-EX23-530 RevisedList of Figures List of Tables Related Documents About This ManualOverview Chapter Title PurposeViii DBS-EX23-530 Revised April Introduction to the Isdn Interface TopicDBS-EX23-530 Revised April Framing Options OverviewDescription of the Isdn Interface Introduction to the Isdn Interface OverviewInformation Needed from CO Comments / Examples Pre-Installation RequirementsOrdering Isdn Typical Information for CO Comments ExamplesLpic Information Needed from CO Site Information Typical Information for CO Site InformationSpan Item Master Cabinet Span Slave Cabinet Span ESFWhat You Must Purchase DBS EquipmentCSU Equipment Page Installation DBS-EX22-530 Revised April Hardware Requirements Installation GuidelinesGuidelines MaximumsGuidelines Installation Trunk Assignments for Single-Cabinet Systems Trunk Assignments for Double-Cabinet Systems System Size Master Slave Trunk Master Cabinet Slave Cabinet NumberTrunk Master Cabinet Slave Cabinet Number Trunk Master Cabinet Slave Cabinet Number Trunk Master Cabinet Slave Cabinet Number Trunk Master Cabinet Slave Cabinet Number Installation Procedures Installation ProceduresInstalling the CSU If you’re installing Use this procedureInstallation Installation Procedures Parameter System ConfigurationInstalling an Isdn in a Single Cabinet Attach the Sync Unit to the CPC-EX card Sync Unit installation MDF card installation Distance from the DBS to the CSU To 150 ft 150-450 ft 450-655 ftPins Designation RJ48 Pin DesignationsIsdn cabinet connections, single-cabinet installation Installation Installation Procedures Installation Procedures Installation Installation Procedures Slave Cabinet Quick-Start Programming DBS-EX23-530 Revised April Before You Begin Quick-Start Programming Before You BeginMinimum Programming DBS-EX22-530 Issued 10/23/98Programming Initial Isdn Options Programming Initial Isdn Options Quick-Start ProgrammingQuick-Start Programming Programming Initial Isdn Options =Free run internal clockingNone DisablePublic = Loop startSend as is Determine Type and PlanFF1 9# 4# 5# 5# 3# 0-2# NSF Multiple did Programming =DID data on display=Off Typical Central Office Configurations CO Type 0 4ESSProgramming Reference DBS-EX23-530 Revised April System Size Isdn System SettingsProgramming Reference Isdn System Settings =T1Clock Settings Isdn System SettingsProgramming Reference=None Isdn System Settings Programming Reference System-Wide Timers Programming Reference System-Wide TimersSystem-Wide Timers Programming Reference 15=Infinite=4 sec =30 sec System-Wide Timers Programming Reference Programming Reference System-Wide Timers Digital Pad Settings Digital Pad Settings Programming ReferenceProgramming Reference Digital Pad Settings SLT Isdn #2Extension Port Settings Digital Pad SettingsProgramming ReferenceTrunk Port Settings Programming ReferenceDigital Pad SettingsTrunk Signaling Master and Slave SettingsTrunk Configuration Master and Slave Settings Programming ReferenceProgramming Reference Alarm Settings Alarm SettingsAlarm Descriptions Alarm Description NotificationAlarm Settings Programming Reference Parameter Address FunctionSlip Alarms Alarm Transmission Options =YesAlarm Timers Programming ReferenceAlarm Settings=10 ms Error Counters for FF Alarm Keys Programming Reference Alarm Settings Alarm Settings Programming Reference Alarm Relay Controls =Off Alarm relay does not closeAlarm Settings Programming Reference =Auto Trunk Settings Trunk Settings Programming Reference=Do not reset Programming Reference Trunk Settings Public networkDisable NoneSend as is with Send as is with leadingTrunk Settings Programming Reference =Off Extension Settings Extension Settings Programming ReferenceFF Key Settings Programming Reference FF Key SettingsAlarm Master Isdn Slave Isdn Special Isdn Function Codes Special Isdn Function Codes Programming ReferenceProgramming Reference Special Isdn Function Codes Yellow Appendix a CPC-EX 2.3 Updates New FeaturesSoftware Corrections Port Voice Mail Support via API ProgrammingOff-Hook Voice Announce Ohva via API Small LCD Soft Key Support via APICall Record Ohva via API Special Features UNA TransferSetting Value UNA Call ReversionForwarding to UNA for CO Held Call DBS-2.3-400 DBS Manual Revised April A-9 All Ring Group Private Password FF1 6# 3# NNNN#Terminal Programming Through a Direct Connection ON/OFF #93Terminal Programming Through Disa Terminal Programming Commands Additional RAI Access MethodTerminal Programming Through Additional RAI Access Method Command DescriptionDBS-2.3-400 DBS Manual Revised April A-15 Isdn Upgrade Procedure Isdn Programming FlexibilityName Key Sequence Master Cabinet Set-Up DMS100 Send as isDetermine Type and Plan Slave Cabinet Set-Up DMS-100Typical Central Office Configurations Lucent AT&T 4ESS Lucent AT&T 5ESSNortel NT DMS100 Info Needed from CO Comments examplesTypical Info for CO Comments examples Will exceed the total number of B channels DBS-2.3-400 DBS Manual Revised April A-23 Feature Changes Affected ItemsFF1 2# 2# 7# System Speed Bins 257- 500 Unavailable Index Revised April DBS-EX23-530 Index-iSync cable 2-18, 2-21, 2-23 Sync loss alarm Index-ii DBS-EX23-530 Revised April