Installing The Charging/Communication Cradle
To install and use the HomeBase, IntelliBase or IntelliBase+, you need the following equipment:
•HomeBase/IntelliBase/IntelliBase+ with power supply
•Serial cable
Set the Dolphin HomeBase/IntelliBase/IntelliBase+ on a dry, stable surface, such as a desktop near an electrical outlet. Be sure to provide enough workspace with good lighting for the user to view and operate the Dolphin terminal while it is in the HomeBase/ IntelliBase.
Connecting the Cables
Connect the HomeBase/IntelliBase/IntelliBase+ to the host computer or other device by plugging an
The HomeBase/IntelliBase Communication Port is configured as a DCE device. To communicate with a DTE device such as a computer, use a standard (or
You can make your own cables by following the pin configuration in the chart below. To do so, you must determine if your host
HomeBase /Host | IBM AT DB9 | IBM XT | Modem DB25 | |
Port (DCE) | (DTE) | DB25 (DTE) | (DCE) | |
Pin / Input Signal |
|
|
| |
2 | / (RD) | 2 | 3 | 2 |
3 | / (TD) | 3 | 2 | 3 |
5 | / (SG) | 5 | 7 | 7 |
4 | / (DTR) | 4 | 20 | 6 |
6 | / (DSR) | 6 | 6 | 20 |
7 | / (RTS) | 7 | 4 | 5 |
8 | / (CTS) | 8 | 5 | 4 |
|
|
|
|
|
The HomeBase/IntelliBase/IntelliBase+ cannot be
Connect the power supply to the charging/communication cradle. Plug the AC transformer into the Dolphin HomeBase/ IntelliBase/IntelliBase+ 5 Volt DC power supply connector. The AC wall transformer provided can power only one HomeBase/ IntelliBase/IntelliBase+. HHP recommends that you leave the Dolphin HomeBase/IntelliBase/IntelliBase+ connected to its power source at all times, so that it is always ready to use.
Set the baud rate switch to the communication mode you are going to use. Refer to Table 2 for HomeBase switch settings or Table 3 for IntelliBase/IntelliBase+ switch settings.
6 - 9