Heat Controller DMC24DB-1, DMH24DB-1 manual Product Specifications, Operation, Unit On Remarks

Page 12

Product Specifications

Product Specifications

DMC24DB-1

 

 

Operation

Item

 

Unit

Cooling Capacity

Btu/h

Heating Capacity

 

Moisture Removal

/h(ft3/h)

Power Source

ø, V, Hz

Air Circulation

m3/min(ft3/min)

Noise Level

 

dB(A)

( Hi / Med / Low )

 

Input

Cooling

W

Heating

 

 

Runnig

Cooling

A

Current

Heating

 

E.E.R.

Cooling

Btu/h.w

C.O.P.

Heating

-

Dimensions(W x H x D)

mm(in)

Net. Weight

 

kg(lb)

Service Valve

mm(In)

Refrigerant(R-410A)

g(lb)

Airflow Direction Control(Up & Down) Remote Controller Type

Sleeping Operation

Drain Hose

2-Unit On

 

1-Unit On

Remarks

 

 

23,600/24,000

11,800/12,000

208/230V

-

 

-

 

2.4(0.085)

 

1.2(0.042)

at 230V

 

1Ø, 208/230V, 60Hz

 

Indoor

9.4(331.9)

 

Outdoor

 

53(1871.8)

 

Indoor

36/32/29

at 230V

Outdoor

 

54

 

 

2,390/2,390

 

1,420/1,420

 

-

 

-

 

10.1/10.1

 

6.3/6.3

208/230V

-

 

-

 

 

9.9/10.1

 

8.3/8.5

 

-

 

-

 

Indoor

895 x 282 x 165(35.2x11.1x6.5)

 

Outdoor

870 x 800 x 320(34.2x31.5x12.6)

 

Indoor

 

9.5

 

Outdoor

 

69

 

Liquid

 

6.35(1/4)

 

Gas

 

9.52(3/8)

 

1,600(3.5)

 

at 7.5m

 

 

O

 

 

L.C.D Wireless

 

 

 

O

 

 

 

O

 

12Multi type Air Conditioner

Image 12
Contents Heat CONTROLLER, INC Table of Contents Symbols Used in this Manual Combination tableSafety Precautions InstallationBe sure not to do Be sure to follow the instruction Control box securely Cuit and breakerDo not install, remove, or re Do not install the product on aDefective installation stand Do not allow water to run into electric partsWhen the product is soaked Not enter the productFlooded or submerged, contact Install the drain hose to ensure that Keep level even when Installing the productUse two or more people to lift and transport the product Operational Be careful and avoid personal injury Dimensions Indoor UnitSplit Type Indoor Outdoor Unit 24kBtu/hProduct Specifications DMC24DB-1Operation UnitDMH24DB-1 Installation Installation PartsInstallation Tools Rooftop Installations Select the best locationIndoor unit Outdoor unitPiping length and elevation Multi Piping Type24k Fixing Installation PlateStandard Type Flaring Work and Connection of Piping Flaring workConnecting the Piping CheckIndoor Wrap the insulation material around the connecting por- tion For left rear piping Plastic bands Insulation material Connection Indoor Remote Control Preparationoptional Outdoor Outdoor unitConnecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the Indoor unitConnect the cable to the Outdoor unit Outdoor unitConnection method of the connecting cableExample How to connect wiring to the terminalsConnect the cable to the indoor unit Checking the drainage To check the drainageDrain piping Forming the piping Down to upAir Purging and Evacuation Checking methodRepeat evacuation procedure for each indoor unit EvacuationFinishing the job Charging AdditionalTest Running Split TypeCooling Mode Operation Soft Dry Operation ModeHeating Mode Operation OperationDefrost ControlHeating Fuzzy OperationFuzzy Operation for Cooling On-Timer Operation Off-Timer OperationAirflow Speed Selection Fuzzy Operation for DehumidificationOff-Timer = On-Timer Operation Sleep Timer OperationChaos Swing Mode Chaos Natural Wind ModeForced Operation Buzzer Sounding OperationFunction of Indoor Unit Split Type Indoor UnitFunction of Outdoor Unit Remote Control Operation Cooling Model , Heat Pump Model15 2nd F Button Disassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Motor Cover Schematic Diagram Electronic Control DeviceIndoor Unit Outdoor Unit TMP87CM41FRY-4WAY RY-LIQ RY-GAS RY-FANL RY-FANH Wiring Diagram Room Type Indoor UnitComponents Locations Bottom ViewDisplay Assembly Split Type 6871A20680 Component side Solder side Troubleshooting Guide Refrigeration Cycle DiagramDMH24DB-1 DMC24DB-1Indoor Error Outdoor ErrorError Indicator Self-diagnosis FunctionCycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Procedure Specification RemedyProduct doesnt operate with the remote controller Compressor/Outdoor Fan are dont operate Check Point Comp. on Comp. OFFTrouble 4 When indoor Fan does not operate NectorTroubleshooting Guide Error Code Check PointIndoor air sensor Indoor inlet pipe sensorPower input AC 230V.Outdoor, Indoor Communication line is shorted at GNDError Title Cause of error Check point & Normal condition Title Cause of error Check point & Normal condition Outdoor air sensorCondensor pipe sensor Pipe sensorWay, 3-way Valve Way Valve Liguid SideProcedure Pumping downAir purging of the charge hose Set the liquid side valve to the closed positionMount the valve caps and the service port caps EvacuationAll amount of refrigerant leaked Mount the valve stem nuts and the service port nut Gas ChargingAfter Evacuation Connect the gauge to the charging cylinderHeat CONTROLLER, INC
Related manuals