Heat Controller DMC24DB-1, DMH24DB-1 manual Piping length and elevation, Multi Piping Type, 24k

Page 16

Installation

Piping length and elevation

Multi Piping Type

 

 

Max total length of

Max length of each

 

Min length of each

Max Elevation

 

Max elevation

 

 

 

between each

 

Capacity(Btu/h)

 

 

 

between indoor

 

all pipes (A+B)

pipe (A/B)

 

pipe (A/B)

indoor unit and out-

 

 

 

units (h2)

 

 

 

 

 

 

 

 

door unit (h1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24k

 

30m(100ft)

 

15m(50ft)

 

3m(10ft)

7.5m(25ft)

 

 

7.5m(25ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Capacity

 

 

 

 

 

Pipe Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Btu/h)

 

Gas

 

Liquid

 

Standard Length

 

Additional Refrigerant

 

 

 

 

 

 

 

 

 

 

 

12K

 

3/8"

 

1/4"

 

 

7.5m(25ft)

 

 

20g/m(0.32oz/ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

24k

A

B

h1

h1

B

CAUTION: Capacity is based on standard length and maximum allowance length is on the basis of reliability. Oil trap should be installed every 5~7 meters (16.4~23.0ft).

16Multi type Air Conditioner

Image 16
Contents Heat CONTROLLER, INC Table of Contents Symbols Used in this Manual Combination tableSafety Precautions InstallationBe sure not to do Be sure to follow the instruction Control box securely Cuit and breakerDo not install, remove, or re Do not install the product on aDefective installation stand Do not allow water to run into electric partsNot enter the product When the product is soakedFlooded or submerged, contact Installing the product Install the drain hose to ensure that Keep level even whenUse two or more people to lift and transport the product Operational Be careful and avoid personal injury Indoor Unit DimensionsSplit Type Indoor Outdoor Unit 24kBtu/hProduct Specifications DMC24DB-1Operation Unit DMH24DB-1 Installation Parts InstallationInstallation Tools Rooftop Installations Select the best locationIndoor unit Outdoor unitMulti Piping Type Piping length and elevation24k Fixing Installation PlateStandard Type Flaring Work and Connection of Piping Flaring workCheck Connecting the PipingIndoor Wrap the insulation material around the connecting por- tion For left rear piping Plastic bands Insulation material Connection Indoor Remote Control Preparationoptional Outdoor Outdoor unitConnecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the Indoor unitConnect the cable to the Outdoor unit Outdoor unitConnection method of the connecting cableExample How to connect wiring to the terminalsConnect the cable to the indoor unit To check the drainage Checking the drainageDrain piping Forming the piping Down to upAir Purging and Evacuation Checking methodEvacuation Repeat evacuation procedure for each indoor unitFinishing the job Charging AdditionalTest Running Split TypeCooling Mode Operation Soft Dry Operation ModeHeating Mode Operation OperationFuzzy Operation Defrost ControlHeatingFuzzy Operation for Cooling On-Timer Operation Off-Timer OperationAirflow Speed Selection Fuzzy Operation for DehumidificationOff-Timer = On-Timer Operation Sleep Timer OperationChaos Swing Mode Chaos Natural Wind ModeForced Operation Buzzer Sounding OperationFunction of Indoor Unit Split Type Indoor UnitFunction of Outdoor Unit Cooling Model , Heat Pump Model Remote Control Operation15 2nd F Button Disassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Motor Cover Electronic Control Device Schematic DiagramIndoor Unit Outdoor Unit TMP87CM41FRY-4WAY RY-LIQ RY-GAS RY-FANL RY-FANH Wiring Diagram Room Type Indoor UnitComponents Locations Bottom ViewDisplay Assembly Split Type 6871A20680 Component side Solder side Troubleshooting Guide Refrigeration Cycle DiagramDMH24DB-1 DMC24DB-1Indoor Error Outdoor ErrorError Indicator Self-diagnosis FunctionCycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Procedure Specification RemedyProduct doesnt operate with the remote controller Compressor/Outdoor Fan are dont operate Check Point Comp. on Comp. OFFTrouble 4 When indoor Fan does not operate NectorTroubleshooting Guide Error Code Check PointIndoor air sensor Indoor inlet pipe sensorPower input AC 230V.Outdoor, Indoor Communication line is shorted at GNDError Title Cause of error Check point & Normal condition Title Cause of error Check point & Normal condition Outdoor air sensorCondensor pipe sensor Pipe sensorWay, 3-way Valve Way Valve Liguid SideProcedure Pumping downAir purging of the charge hose Set the liquid side valve to the closed positionEvacuation Mount the valve caps and the service port capsAll amount of refrigerant leaked Mount the valve stem nuts and the service port nut Gas ChargingAfter Evacuation Connect the gauge to the charging cylinderHeat CONTROLLER, INC
Related manuals
Manual 35 pages 26.68 Kb Manual 29 pages 18.54 Kb