Haier CWH24A, CWH12A, CWH18A manual Through-the-Wall Cabinet Installation

Page 11

Through-the-Wall Cabinet Installation

NOTES:

Handle the air conditioner gently.

Be sure your air conditioner cabinet does not fall out of the opening during installation or removal.

The location where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded

3 prongoutlet.

Do not block the louvers on the front panel.

Do not block the louvers on the outside of the air conditioner.

It is the customer's responsibility and obligation to have this product installed by a qualified technician familiar with through-the-wall room air conditioner installations.

Option 1-Wood, metal or plastic molding

When using a wood, metal or plastic molding, the wood frame should line up with the inside wall as shown.

A B C

D

A. Molding

C. Wood frame

B. Inside wall

D. Louvers

Option 2-Plastered wall with no molding

If the plastered wall is to be flush with the cabinet and no molding is used, the wood frame must be set ¹⁄₂" (13 mm) into the inside wall.

A B C

D

A. Plastered wall

C. Wood frame

B. Inside wall

D. Louvers

Install Wood Frame

1.Construct the wood frame. See "ocation Requirements”for dimensions.

2.Measure the outside width and height of the frame to determine the wall opening dimensions.

3.Cut the opening through the wall. Remove and save the insulation.

NOTES:

Dimension for depth depends on the wall thickness and the type of molding.

Do not block louvers in the air conditioner cabinet.

Use 1" (2.5 cm) or thicker lumber for the wood frame.

A

B

C

A. Outside width

C. Depth

B. Outside height

4.Apply the wood preservative to the outside exposed surface.

5.Insert the frame in the wall opening. Square and level the frame.

6.Attach the frame securely to the wall.

Install Cabinet into Wood Frame

1.Insert the cabinet into the framed wall opening.

A

A.Trim

2.Use a level to check that the cabinet is level side to side.

A

A.Level

3.Check that the air conditioner cabinet is tilted to the outside so that water will run to the outside.

Complete Through-the-Wall Installation

1.Reuse the insulation to seal opening between the cabinet and the frame.

2.Use the existing holes and six 1" (2.5 cm) wood screws (not provided) to attach the cabinet to the frame.

NOTE: Do not overtighten the screws or the cabinet will distort and provide a poor air seal between the cabinet and the air conditioner.

3.Caulk all outside wall openings around the cabinet.

10

Image 11
Contents Climatiseurdepièce Table DES Matières Table of ContentsAIR Conditioner Safety Tools Needed Through-the-Wall InstallationTools and Parts Parts suppliedLocation Requirements Window InstallationRecommended Grounding Method Power Supply CordElectrical Requirements Remove packaging materials To test your power supply cordUnpack the Air Conditioner Bottom view Window Installation-Prepare the CabinetBack view Window Installation-Position Cabinet in window Windowsill View Complete Window InstallationThrough-the-Wall Cabinet Installation Complete Installation Mode Starting Your Air ConditionerCool Only Models Filter Monitor TemperatureTimer Delay Fan SpeedTo see or change the remaining time in hours Using the Remote ControlTo clear Timer delay program PowerSleep Control TimerSuper Control Normal Sounds Changing Air DirectionExhaust Air Vent Annual Maintenance Cleaning the Air FilterCleaning the Front Panel Repairing Paint DamageWater drips from cabinet into your house Air conditioner blows fuses or trips circuit breakersAir conditioner seems to run too much InCanada Assistance or ServiceIntheU.S.A Page Votre sécurité et celle des autres est très importante Sécurité DU ClimatiseurOutillage et pièces Exigences D’INSTALLATIONExigences d’emplacement 23 58,4 cm Installation dans une fenêtreExigences électriques Pour tester le cordon dalimentation Méthode recommandée de liaison à la terreCordon dalimentation Enlèvement des matériaux demballage Instructions DinstallationDéballage du climatiseur Vue de dessous Installationdans unefenêtre-Préparationde la caisseVue arrière Placez le boîtier dans la fenêtre Installation dans une fenêtre-Préparationde la fenêtreVue du seuil du châssis de fenêtre Installation des rideaux latérauxAchever l’installation sur la fenêtre Vue du châssis de fenêtreOption 2-Mur de plâtre sans moulure Installation de la caisse dansun murInstallation du cadre de bois Option 1-Moulure de bois, métal ou plastiqueInsérer le climatiseur dans la caisse Achever l’installationModèles du refroidissement seulement Utilisation DU ClimatiseurMise en marche du climatiseur Filter Monitor témoin du filtre Fan Speed vitesse du ventilateurMode Pour voir ou modifier le temps résiduel en heures Timer Delay minuterie différéeTempérature Commande Super Utilisationde la télécommandeSystème de commande Smart Power alimentationTimer Minuterie Commande Sleep veillePour voir le temps résiduel en heures ou le modifier Changement de direction de lairVentilation Sons normauxDépannage Entretien DU ClimatiseurLe climatiseur semble fonctionner trop longtemps AuCanada Assistance OU ServiceAuxÉtats-Unis Page Made In China