Tyco Electronics P5400 manual MM-012099-001, Rev. B

Page 2

MM-012099-001, Rev. B

 

 

MANUAL REVISION HISTORY

 

 

 

REV

DATE

REASON FOR REVISION

-

Sep/07

Initial release.

 

 

 

A

Oct/07

Added SAR information for UHF-H series P5400 portable radios.

 

 

 

B

Mar/08

Added SAR information for VHF series P5400 portable radios and updated the product warranty.

 

 

 

M/A-COM Technical Publications would particularly appreciate feedback on any errors found in this document and suggestions on how the document could be improved. Submit your comments and suggestions to:

Tyco Electronics Wireless Systems Segment

M/A-COM, Inc.

Fax your comments to: 1-434-455-6851

Technical Publications

or

221 Jefferson Ridge Parkway

e-mail us at: techpubs@tycoelectronics.com

Lynchburg, VA 24501

 

ACKNOWLEDGEMENTS

The software contained in this device is copyrighted by M/A-COM, Inc. Unpublished rights are reserved under the copyright laws of the United States.

This device is made under license under one or more of the following U.S. Patents: 4,590,473; 4,636,791; 5,148,482; 5,185,796; 5,271,017; 5,377,229; 4,716,407; 4,972,460; 5,502,767; 5,146,497; 5,164,986; 5,185,795.

CREDITS!

EDACS are registered trademarks of M/A-COM, Inc.

TORX is a registered trademark of CAMCAR division of TEXTRON, Inc.

All other product and brand names are trademarks, registered trademarks, or service marks of their respective holders.

NOTICE!

This manual covers M/A-COM products manufactured and sold by M/A-COM, Inc.

This product conforms to the European Union WEEE Directive 2002/96/EC. Do not dispose of this product in a public landfill. Take it to a recycling center at the end of its life.

The voice coding technology embodied in this product is protected by intellectual property rights including patent rights, copyrights, and trade secrets of Digital Voice Systems, Inc. The user of this technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code, or in any other way convert the Object Code into human-readable form.

Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier. Any repairs, alterations, or substitution of recommended parts made by the user to this equipment not approved by the manufacturer could void the user’s authority to operate the equipment in addition to the manufacturer’s warranty.

This manual is published by M/A-COM, Inc., without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies of current information, or improvements to programs and/or equipment, may be made by M/A-COM, Inc., at any time and without notice. Such changes will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of M/A-COM, Inc.

Copyright© 2007-2008 M/A-COM, Inc. All rights reserved.

2

Image 2
Contents P5400 Series MM-012099-001, Rev. B Table of Contents Menu 28.1 10.8.1 116 117Tables Safety Section Safety Conventions Safety Training Information RF Exposure GuidelinesRF Exposure Compliance Testing Distances Electromagnetic INTERFERENCE/COMPATIBILITYEfficient Radio Operation Antenna Care and ReplacementOperating Tips Electronic DevicesPotentially Explosive Atmospheres AircraftElectric Blasting Caps Conditioning NiCD Battery Packs Conditioning Battery PacksConditioning NiMH Battery Packs BatteriesAdditional Information Charging Battery PacksBattery Pack Usage Charging GuidelinesChanging the Battery Pack Removing the Battery PackBattery Disposal Attaching the Battery PackProduct Information Introduction Water ResistanceOptions and Accessories Options and AccessoriesCarrying Case Accessories User Interface P5400 Portable RadioControls Buttons and KnobsKeypad P5450 Scan Model Front Panel P5400 Front Keypad FunctionsSample Display Edacs Mode DisplayRadio Status Icons Status Icons DescriptionsUniversal Device Connector Tri-Color LEDThis page intentionally left blank Edacs Operation Power ON-OFF Volume Knob Edacs OperationP5450 Scan Radio Front Panel P5450 Keypad Functions KEY Function Radio Display in Edacs Mode DisplayRadio Status Icons Status Icon DescriptionsTRI-COLOR LED Status MessagesError Messages System Selection Alert TonesTurning on the Radio Alert Tones11.1 P5470 Model GROUP/CHANNEL SelectionModify Scan List 11.2 P5450 Model Menu Item Selection ProcessBacklight Menu Item Selection Parameter Menu Item InformationFeature Display Parameter Setting Information DisplayBacklight ON/OFF Contrast AdjustHIGH/LOW Power Adjustment Declaring AN EmergencyClear Mode Using the Menu ButtonUsing the Pre-Programmed Option Button Digital ModePrivate Mode System Encryption Key DisplayPrivate Operation Receiving an Encrypted CallAdding Groups to a Scan List Scanning Trunked GroupsTurning Scan On and Off P5450 Model RadioP5470 Model Radio Nuisance Delete Scanning Trunked SystemsDeleting Groups from a Scan List Wide Area System ScanningProScan Emergency OperationPriority System Scan Receiving an Emergency CallReceiving and Responding to an Individual Call Individual CallsDeclaring an Emergency Call Sending an Individual Call 11 Calls Received ListsReceiving a Telephone Interconnect Call Telephone Interconnect CallsCall Storage Lists Dual-Tone Multi-Frequency Overdial/Conventional Mode Sending a Telephone Interconnect CallP5450 Model Radio Method 2 P5470 model radios only Programmable EntriesSTATUS/MESSAGE Operation Status Operation Message OperationPortable Data Dynamic Regroup OperationMacro KEY Operation Emergency OperationData OFF Operation Scan Lockout ModeDisplays Data on OperationData Lockout Mode This page intentionally left blank Conventional Operation Conventional Operation Power ON-OFF Volume Knob Voice Group Selection Control Knob P5450 Scan Radio Front Panel P5470 System Radio Front Panel Radio Display Battery Charge Icons Full Cycle Radio Status IconsMode no repeater Error Messages Name Tone Description1 P5470 Model MethodNuisance Delete 2 P5450 ModelBacklight Menu Item Parameter Only. No user selectable settings LID in EDACS/EA. In Conv it has no Using the Menu Button Using the Pre-Programmed Option ButtonReceiving a Call Sending a Call This page intentionally left blank P25 Operation 10 P25 Operation Voice Group Selection Control Knob EMERGENCY/ Home Button Enter key P5470 System Radio Front Panel Display Display Descriptions TRI-COLOR LED Error Messages Call queued for processing GROUP/CHANNEL Selection 10.9.1 P5470 Model10.9.2 P5450 Model Selectable settings Select Telephone Press Digital Voice Operation 11 System Encryption Key Display Group Clear Digital Private Programming Receive Transmit Scanning Trunked Groups 100 101 102 103 104 105 106 107 108 109 110 Transmitting a Group Call Group Calls in P25 ModeExiting Data Calls Individual Calls in P25 Mode Emergency Group Calls in P25 ModeReceiving an Emergency Group Call 114 Technical Assistance Warranty Information Technical Assistance Basic Troubleshooting TroubleshootingBattery Warranty 119 Tyco Electronics Wireless Systems Segment