Friedrich SS14N10*, SS12N10* Troubleshooting Tips, Problem Possible Cause Possible Solution

Page 60

TROUBLESHOOTING TIPS

NOTE: To more accurately identify the problem, first check for current maintenance alerts and their history.

Problem

 

Possible Cause

Possible Solution

 

The unit is turned to the off position,

Turn the unit to the on position and raise or

 

lower temperature setting (as appropriate) to

 

 

 

 

 

 

call for operation.

 

 

 

Plug into a properly grounded 3 prong

 

The LCDI power cord is unplugged.

receptacle. See “Electrical Rating Tables” on

 

pg. 6 for the proper receptacle type for your

 

 

 

 

 

 

unit.

Unit does not operate.

The LCDI power cord has tripped

Press and release RESET (listen for click;

 

Reset button latches and remains in) to resume

 

(Reset button has popped out).

 

operation.

 

 

 

 

The circuit breaker has tripped or

Reset the circuit breaker, or replace the fuse as

 

applicable. If the problem continues, contact a

 

the supply circuit fuse has blown.

 

licensed electrician.

 

 

 

 

There has been a local power

The unit will resume normal operation once

 

failure.

power has been restored.

 

Other appliances are being used on

The unit requires a dedicated outlet circuit, not

 

the same circuit.

shared with other appliances.

 

An extension cord is being used.

Do NOT use an extension cord with this or any

Unit Trips Circuit Breaker or

other air conditioner.

 

 

 

 

Replace with a circuit breaker or time-delay

Blows Fuses.

 

 

 

The circuit breaker or time-delay

fuse of the proper rating. See “Electrical

 

fuse is not of the proper rating.

Rating Tables” on pg. 6 for the proper circuit

 

 

 

breaker/fuse rating for your unit. If the problem

 

 

 

continues, contact a licensed electrician.

 

The LCDI power cord can trip

Press and release RESET (listen for click;

 

(Reset button pops out) due to

 

Reset button latches and remains in) to resume

 

disturbances on your power supply

 

normal operation.

 

line.

 

 

 

 

LCDI Power Cord Trips (Reset

Electrical overload, overheating, or

Once the problem has been determined and

Button Pops Out).

corrected, press and release RESET (listen for

cord pinching can trip (Reset button

 

click; Reset button latches and remains in) to

 

pops out) the LCDI power cord.

 

resume normal operation.

 

 

 

 

NOTE:

A damaged power supply cord must be replaced with a new power supply cord

 

 

obtained from the product manufacturer and must not be repaired.

 

The return/discharge air grille is

Ensure that the return and/or discharge air

 

paths are not blocked by curtains, blinds,

 

blocked.

 

furniture, etc.

 

 

 

 

Windows or doors to the outside are

Ensure that all windows and doors are closed.

 

open.

 

 

 

The temperature is not set at a cool

Adjust the Temperature control to a cooler or

 

enough/warm enough setting.

warmer setting as necessary.

Unit Does Not Cool/Heat

 

 

remove obstruction.

On And Off Too Frequently.

 

 

The indoor coil or outdoor coil is

Clean the coils, (See Routine Maintenance), or

 

 

dirty or obstructed.

remove obstruction.

 

There is excessive heat or moisture

Be sure to use exhaust vent fans while cooking

 

or bathing and, if possible, try not to use heat

 

(cooking, showers, etc.) in the room.

producing appliances during the hottest part of

 

 

 

the day.

 

The temperature of the room you

Allow additional time for the air conditioner to

 

are trying to cool is extremely hot.

cool off a very hot room.

59

Image 60 Contents
Cool Only Heat PumpTable Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Repair Hazards Property Damage Hazards Introduction Components IdentificationModel and Serial Number Location Unit Identification Specifications Refrigeration System Performance DataKeep the filter clean Unit placementProper installation of seal gasket Provide good air flowElectrical Data Electric Shock HazardFire Hazard Electrical Shock Hazard Kuhl Control Options FriedrichLink AdapterControl Panel and Display Identification Control Panel Operation Instructions Timer Schedule Button ºF ºC SelectDIM Function AlertsControl Panel Lock External Control StatusTo Turn On the Timer or Schedule Selected Timer or Schedule Options 1 or 2 SelectionTimer Start Time Timer SettingsSet theTimer Stop Time Timer on ScenariosTimer OFF Scenarios Timer Schedule Control BlockRemote Control Operation Remote Control Operation Unit Operation Front PanelElectronic Control Sequence of Operation Compressor OperationHeating Mode Control Operation Heat Control Heat Pump OnlyHeat Pump With Electric Heat Operation ConditionElectric Heat Operation in Cool with Electric Heat Units Compressor Lock Out Time Using ModeRemoving the Front Cover Replacing the Indoor Coil Thermistor Swing OutAir flow direction adjustment Fresh air and exhaust controlComponents Testing Capacitor Check with Capacitor AnalyzerCapacitor Connections FAN MotorTesting the Heating Element Electric Shock Hazard Heating ElementHeating Element Heat Pump Models Drain PAN ValveUser Interface Control Board Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressure410A Sealed Refrigeration System Repairs Refrigerant ChargingMethod Of Charging / Repairs Burn HazardFreeze Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Hermetic Components Check Capillary Tube SystemsReversing Valve DESCRIPTION/OPERATION Testing the Reversing Valve Solenoid Coil Reversing Valve in Heating ModeProcedure For Changing Reversing Valve Touch Test in Heating/Cooling CycleExplosion Hazard Single Phase Connections Single Phase Running and L.R.A. TestLocked Rotor Voltage L.R.V. Test Determine L.R.VSingle Phase Resistance Test Ground TestChecking Compressor Efficiency Recommended procedure for compressor replacement High TemperaturesHigh Pressure Hazard Routine Maintenance Sleeve / Drain Decorative Front CoverClearances Filter assembly Heat pumps operate differently Condensation is normalFrosting NoisesIf you require further assistance Our specialists are able to assist you withDC-2 Drain Kit Part No Carbon Filter KitsSee codes chart on next Error Codes and Alarm Status Test Mode Temp Room AIR Conditioner Unit Performance Test Data Sheet HOW is ALL of the INSTALLATION? Good BADJOB Name Techs Name = SQ/CU/FTTroubleshooting Tips Problem Possible Cause Possible SolutionTroubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Replace fuse, reset breaker. If repeats, check Possible Cause Possible Solution Problem Possible Cause Possible Solution Heat / Cool only Room AIR Conditioners Troubleshooting Tips Heat Pump Room AIR Conditioners Trouble Shooting Tips Problem Possible Cause ActionSystem Cools When Heating is Desired YESNormal Function of Valve Malfunction of ValveElectronic Control Board Components Identification Contents ProcedureFriedrich Electronic Control KIT Friedrich Model Prefix Schematic Part NO. REV 92170013 Kϋhl Electronic Control Cool only Models SL36N30-A Wiring Diagram Wiring Diagram 92170015 92170016 Kϋhl Electronic Control Heat Pump model YL24N35-A Need to Configure it. Follow the steps below to configure Air Conditioner Message Remote Control MessageAir Conditioning Unit Display Remote Control Display Replacement Instructions Parts Section Parts Section Kühl & Kühl+ Small-Chassis 2012 Parts List SHROUD, SML Kühl & Kühl+ Medium-Chassis 2012 Parts List SHROUD, MED Kühl & Kühl+ Large-Chassis 2012 Parts List Deck LRG Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty AAA Refrigeration Service Customer Satisfaction and Quality AssuranceFriedrich AIR Conditioning CO