Friedrich SS14N10*, SS12N10*, SS15N30*, SS10N10* Kühl & Kühl+ Large-Chassis 2012 Parts List

Page 90

Kühl & Kühl+ Large-Chassis 2012 Parts List

Item

Part Number

Part Description

EL25N35-A

EL36N35-A

SL22N30-A

SL25N30-A

SL28N30-A

SL36N30-A

YL24N35-A

1

61850238

CONDENSOR COIL

 

 

 

 

 

 

1

1

62050222

CONDENSOR COIL

1

1

 

1

1

1

 

1

61850246

CONDENSOR COIL

 

 

1

 

 

 

 

*

61818522

EXPANDED METAL GRILLE PAINTED LRG

1

1

1

1

1

1

1

*

60169120

SCRIPT FRIEDRICH 2010 "FESTOON"

1

1

1

1

1

1

1

*

91002900

SPEEDNUT PUSH TYPE

3

3

3

3

3

3

3

2

61896305

EVAPORATOR COIL

 

1

 

 

 

1

 

2

62050004

EVAPORATOR COIL

1

 

 

1

1

 

1

2

62050041

EVAPORATOR COIL

 

 

1

 

 

 

 

*

61834801

STRAINER .375 COIL

1

1

1

1

1

1

3

3

61717134

COMPRESSOR KIT 62200205

 

1

 

 

 

1

 

3

61717131

COMPRESSOR KIT 62200108

1

 

 

1

 

 

1

3

61718113

COMPRESSOR KIT 62200207

 

 

1

 

 

 

 

3

61717130

COMPRESSOR KIT 62200200

 

 

 

 

1

 

 

*

1390000

CAPILLARY TUBE

 

 

 

 

 

 

1

*

3760482

CAPILLARY TUBE

 

 

 

 

 

 

1

*

3760473

CAPILLARY TUBE

2

 

 

2

2

 

 

*

3760512

CAPILLARY TUBE

 

2

 

 

 

2

 

*

3760518

CAPILLARY TUBE

 

 

2

 

 

 

 

4

25022032

REVERSING VALVE KIT + SOLENOID KIT

 

 

 

 

 

 

1

5

62601016

USER INTERFACE SERVICE KIT

1

1

1

1

1

1

1

6

62601013

ELECTRONIC CONTROL SERVICE KIT CL-EH 3SP GEN2

1

1

 

 

 

 

 

6

62601011

ELECTRONIC CONTROL SERVICE KIT COOL 3SP GEN2

 

 

1

1

1

1

 

6

62601012

ELECTRONIC CONTROL SERVICE KIT HP-EH 3SP GEN2

 

 

 

 

 

 

1

7

61080589

CAPACITOR

1

 

 

1

 

 

 

7

61080588

CAPACITOR

 

 

 

 

1

 

 

7

61080520

CAPACITOR

 

 

1

 

 

 

1

7

61080514

CAPACITOR

 

1

 

 

 

1

 

*

61820700

CAPACITOR STRAP 2.0 DIAMETER

1

 

 

1

 

 

 

*

61820702

CAPACITOR STRAP 2.5 DIAMETER

 

1

1

 

1

1

1

 

61820401

CAPACITOR MOUNTING BRACKET

1

1

1

1

1

1

1

8

25063605

COIL SOLENOID 208/230VAC

 

 

 

 

 

 

1

10

61878612

HEATER 5.2 KW @ 230V

1

1

 

 

 

 

1

11

61871466

FAN MOTOR

 

1

 

 

 

1

 

11

61871467

FAN MOTOR

1

 

1

1

1

 

1

12

60500394

SUPPLY CORD 13A 250V

 

 

1

 

 

 

 

12

60500398

SUPPLY CORD 20A 250V

 

 

 

1

1

 

 

12

60500399

SUPPLY CORD 30A 250V

1

1

 

 

 

1

1

13

60179904

CONDENSATE DRAIN VALVE

1

1

 

 

 

 

1

14

60610617

BLOWER WHEEL

 

 

 

 

1

 

 

14

60610619

BLOWER WHEEL

1

1

 

 

 

1

 

14

60610620

BLOWER WHEEL

 

 

1

1

 

 

1

14

60610620

BLOWER WHEEL

1

 

 

 

 

 

 

15

61818100

SCROLL LRG

1

1

1

1

1

1

1

16

60542007

FAN BLADE

1

1

1

1

1

1

1

17

61807702

SHROUD, LRG

1

1

1

1

1

1

1

18

61806700

MOUNT, FAN MOTOR

1

1

1

1

1

1

1

19

61907111

INNERWALL ASY LRG

1

1

1

1

1

1

1

20

61821500

ASSY DOOR/SLIDE S/M/L

1

1

1

1

1

1

1

*

61814806

CONNECTOR FRESH AIR LRG

1

1

1

1

1

1

1

89

Image 90
Contents Cool Only Heat PumpTable Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Repair Hazards Property Damage Hazards Introduction Components IdentificationModel and Serial Number Location Unit Identification Specifications Refrigeration System Performance DataProper installation of seal gasket Keep the filter cleanUnit placement Provide good air flowElectrical Data Electric Shock HazardFire Hazard Electrical Shock Hazard Kuhl Control Options FriedrichLink AdapterControl Panel and Display Identification Control Panel Operation Instructions Timer Schedule Button ºF ºC SelectControl Panel Lock DIM FunctionAlerts External Control StatusTo Turn On the Timer or Schedule Selected Timer or Schedule Options 1 or 2 SelectionTimer Start Time Timer SettingsSet theTimer Stop Time Timer on ScenariosTimer OFF Scenarios Timer Schedule Control BlockRemote Control Operation Remote Control Operation Unit Operation Front PanelElectronic Control Sequence of Operation Compressor OperationHeating Mode Control Operation Heat Control Heat Pump OnlyHeat Pump With Electric Heat Operation ConditionElectric Heat Operation in Cool with Electric Heat Units Compressor Lock Out Time Using ModeRemoving the Front Cover Replacing the Indoor Coil Thermistor Swing OutAir flow direction adjustment Fresh air and exhaust controlCapacitor Connections Components TestingCapacitor Check with Capacitor Analyzer FAN MotorHeating Element Heat Pump Models Testing the Heating Element Electric Shock HazardHeating Element Drain PAN ValveUser Interface Control Board Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressure410A Sealed Refrigeration System Repairs Refrigerant ChargingMethod Of Charging / Repairs Burn HazardFreeze Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Hermetic Components Check Capillary Tube SystemsReversing Valve DESCRIPTION/OPERATION Testing the Reversing Valve Solenoid Coil Reversing Valve in Heating ModeProcedure For Changing Reversing Valve Touch Test in Heating/Cooling CycleExplosion Hazard Locked Rotor Voltage L.R.V. Test Single Phase ConnectionsSingle Phase Running and L.R.A. Test Determine L.R.VSingle Phase Resistance Test Ground TestChecking Compressor Efficiency Recommended procedure for compressor replacement High TemperaturesHigh Pressure Hazard Routine Maintenance Sleeve / Drain Decorative Front CoverClearances Filter assembly Frosting Heat pumps operate differentlyCondensation is normal NoisesDC-2 Drain Kit Part No If you require further assistanceOur specialists are able to assist you with Carbon Filter KitsSee codes chart on next Error Codes and Alarm Status Test Mode Temp JOB Name Techs Name Room AIR Conditioner Unit Performance Test Data SheetHOW is ALL of the INSTALLATION? Good BAD = SQ/CU/FTTroubleshooting Tips Problem Possible Cause Possible SolutionTroubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Replace fuse, reset breaker. If repeats, check Possible Cause Possible Solution Problem Possible Cause Possible Solution Heat / Cool only Room AIR Conditioners Troubleshooting Tips Heat Pump Room AIR Conditioners Trouble Shooting Tips Problem Possible Cause ActionSystem Cools When Heating is Desired YESNormal Function of Valve Malfunction of ValveElectronic Control Board Components Identification Contents ProcedureFriedrich Electronic Control KIT Friedrich Model Prefix Schematic Part NO. REV 92170013 Kϋhl Electronic Control Cool only Models SL36N30-A Wiring Diagram Wiring Diagram 92170015 92170016 Kϋhl Electronic Control Heat Pump model YL24N35-A Need to Configure it. Follow the steps below to configure Air Conditioner Message Remote Control MessageAir Conditioning Unit Display Remote Control Display Replacement Instructions Parts Section Parts Section Kühl & Kühl+ Small-Chassis 2012 Parts List SHROUD, SML Kühl & Kühl+ Medium-Chassis 2012 Parts List SHROUD, MED Kühl & Kühl+ Large-Chassis 2012 Parts List Deck LRG Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty AAA Refrigeration Service Customer Satisfaction and Quality AssuranceFriedrich AIR Conditioning CO

SM18N30*, SS10N10*, SS15N30*, SS12N10*, SS14N10* specifications

Friedrich air conditioners, particularly models SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30*, are renowned for their reliable performance, innovative technologies, and user-friendly features. Designed for both residential and commercial use, these units stand out due to their energy efficiency, advanced cooling capabilities, and versatile operation.

One of the standout features across these models is their energy efficiency. Equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, they help users save on energy costs while reducing their carbon footprint. Specifically, the SS14N10* and SS12N10* models excel in cooling efficiency, ensuring that the spaces they occupy remain comfortably cool even in the hottest conditions. This not only contributes to lower energy bills but also promotes environmental sustainability.

The cooling technologies integrated into these units include advanced inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand of a room. As a result, these air conditioners maintain desired temperatures with minimal fluctuations, ensuring optimal comfort and significant energy savings. Models like SS15N30* and SM18N30* are particularly stellar in maintaining efficiency even during peak usage hours.

Moreover, these air conditioners are equipped with multi-stage filtration systems that enhance indoor air quality. The filters effectively capture dust, allergens, and other pollutants, resulting in cleaner and healthier air for occupants. This is especially important for individuals with allergies or respiratory issues.

User-friendly controls add another layer of convenience. Many models incorporate smart technology allowing users to control the units via mobile apps or home automation systems. This feature enables remote operation, scheduling, and real-time monitoring, making it easier to manage climate conditions effectively.

In terms of design, models like SS10N10* prioritize aesthetics without compromising functionality. They feature sleek, modern designs that seamlessly integrate into various decors, whether in a home or an office. Additionally, quiet operation technology reduces noise levels during functionality, enhancing comfort, particularly in bedrooms or quiet office environments.

Overall, Friedrich’s SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30* models embody the brand's commitment to innovation and customer satisfaction. Their blend of energy efficiency, advanced cooling technology, air quality enhancement, and smart controls positions them as leaders in the air conditioning market, catering to diverse cooling needs while promoting a sustainable future.