Friedrich SS10N10*, SS14N10*, SS12N10* Refrigeration System Performance Data, Specifications

Page 8

REFRIGERATION SYSTEM PERFORMANCE DATA

COOLING

EVAP. AIR TEMP. DEG.

CONDENSER

Discharge

Suction

 

Sub-

OPERATING

ELECTRICAL RATINGS

R-410A

 

BREAKER

F

 

Super Heat

PRESSURES

REF.

Voltage

FUSE

PERFORMANCE

 

 

 

 

 

 

 

DATA*

Discharge Air

Temp.

TEMP DEG. F

Temp

Temp

 

Cooling

Suction

Discharge

Amps

Amps

Locked Rotor

Charge in

 

60 Hertz

Drop F.

 

 

 

 

 

Cool

Heat

Amps

OZ.

 

Amps

SS08N10-A

54

26

114

153

65

7

19

151

400

6.1

 

32.0

26.0

115

15

YS10N10-A

59

21

115

155

67

12

14

147

395

7.8

7.6

50.0

26.5

115

15

SS10N10-A

54

26

114

157

68

16

17

137

392

7.7

 

50.0

27.0

115

15

SS12N10-A

56

24

119

170

60

14

25

135

423

10.0

 

55.0

30.0

115

15

SS14N10-A

55

25

120

171

62

14

23

141

390

12.0

 

63.0

31.0

115

15

SS12N30-A

47

33

114

155

58

10

18

134

393

4.8

 

30.0

31.5

230/208v

15

ES12N33-A

47

33

114

155

58

10

18

135

393

4.8

16.0

30.0

31.5

230/208v

20

YS12N30-A

61

19

118

169

69

18

21

137

413

5.2

5.6

26.0

32.0

230/208v

20

SS15N30-A

54

26

119

174

59

12

34

127

420

6.4

 

32.0

33.5

230/208v

15

ES15N33-A

54

26

119

174

59

12

34

127

420

6.4

16.0

32.0

33.5

230/208v

20

SM15N10-A

55

25

118

153

58

10

18

140

410

12.6

 

63.0

37.0

115

15

 

SM18N30-A

57

23

120

169

61

14

22

136

422

7.4

 

42.0

39.5

230/208v

15

EM18N34-A

57

23

120

169

61

14

22

136

422

7.4

19.5

42.0

39.5

230/208v

30

YM18N34-A

48

32

118

169

53

10

21

126

413

8.5

8.5

44.0

40.0

230/208v

30

SM21N30-A

60

20

123

175

65

10

20

130

448

9.4

 

46.0

40.0

230/208v

15

SM24N30-A

45

35

127

175

50

10

28

119

457

11.2

 

60.5

43.6

230/208v

20

EM24N34-A

45

35

127

175

50

10

28

119

457

11.2

19.5

60.5

43.5

230/208v

30

YL24N35-A

58

22

119

174

64

22

20

124

417

11.1

12.2

47.0

73.0

230/208v

30

SL22N30-A

54

26

119

159

59

10

20

139

409

9.4

 

48.0

57.0

230/208v

15

SL24N30-A

54

26

123

163

58

16

19

132

435

11.2

 

47.0

69.0

230/208v

20

SL28N30-A

54

26

122

173

60

11

26

139

445

12.7

 

60.0

70.5

230/208v

20

SL36N30-A

52

28

130

190

56

13

33

126

480

18.0

 

88.0

72.0

230/208v

30

EL36N35-A

52

28

130

190

56

13

33

126

480

18.0

24.0

88.0

72.0

230/208v

30

*Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity, all systems use R-410A. Test done at highest unit fan speed.

*

*

*

*

*

*

*

*

*

*

*

*

*

*

SPECIFICATIONS

 

 

 

 

 

 

 

 

ENERGY STAR® models

 

 

 

 

 

 

 

 

Energy

Estimated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yearly

 

Moisture

 

 

 

 

 

 

 

Volts

Cooling

Cooling

Heating

Heating

Ratio

Operating

 

Removal -

 

 

Net

Ship

MODEL

Cooling Btu

Heating Btu

Rated

Amps

Watts

Amps

Watts

EER

Cost

COP

Pints/HR

CFM

Sleeve

Wt

Wt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kühl ®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS08N10

7900

-

115

6.1

677

-

-

11.7

$54

-

1.0

265

S

99

121

SS10N10

9500

-

115

7.7

848

-

-

11.2

$67

-

2.0

260

S

106

136

SS12N10

12000

-

115

10.0

1111

-

-

10.8

$88

-

3.0

300

S

112

136

SS14N10

14000

-

115

12.0

1444

-

-

9.7

$115

-

3.5

325

S

116

133

SS12N30

11500/11200

-

230/208

4.8/4.9

1055/1027

-

-

10.9/10.9

$84

-

2.8

275

S

112

134

SS15N30

14500/14300

-

230/208

6.4/6.8

1480/1459

-

-

9.8/9.8

$112

-

3.5

360

S

116

136

SM15N10

14800

-

115

12.0

1358

-

-

10.9

$109

-

3.5

360

M

141

154

SM18N30

17500/17200

-

230/208

7.4/8.0

1635/1607

-

-

10.7/10.7

$131

-

4.6

350

M

140

158

SM21N30

20500/20000

-

230/208

9.4/10.3

2181/2128

-

-

9.4/9.4

$173

-

6.0

425

M

132

153

SM24N30

22300/22000

-

230/208

11.2/11.9

2590/2550

-

-

8.6/8.6

$206

-

10.0

390

M

152

167

SL22N30

21000/20500

-

230/208

9.6/10.2

2188/2092

-

-

9.6/9.8

$174

-

6.0

625

L

191

212

SL24N30

24000/23800

-

230/208

11.2/12.0

2553/2532

-

-

9.4/9.4

$207

-

7.0

640

L

192

213

SL28N30

27500/27000

-

230/208

13.5/14.4

2926/2872

-

-

9.4/9.4

$229

-

8.5

600

L

193

214

SL36N30

36000/35700

-

230/208

19.0/20.5

4235/4200

-

-

8.5/8.5

$338

-

12.0

725

L

212

227

Kühl ® + Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YS10N10*

9400

7500

115

7.8

855

7.6

743

11.0

$68

3.0

1.9

285

S

109

131

YS12N33

11500/11300

9400/9000

230/208

5.2/5.4

1095/1076

5.6/5.8

1132/1139

10.5/10.5

$87

2.4/2.3

3.0

265

S

115

136

YM18N34

18200/17800

17900/17700

230/208

8.5/8.9

1808/1788

8.5/8.7

1833/1761

9.9/9.9

$147

2.5/2.6

5.4

370

M

141

152

YL24N35

23500/23000

23500/23000

230/208

11.1/12.0

2500/2447

12.2/14.3

2610/2575

9.4/9.4

$199

2.6/2.6

7.0

600

L

197

212

Kühl ® + Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ES12N33

11500/11200

10700/8900

230/208

4.8/4.9

1055/1027

16.0/14.7

3500/2900

10.9/10.9

$84

-

2.8

275

S

113

128

ES15N33

14500/14300

10700/8900

230/208

6.4/6.8

1480/1459

16.0/14.7

3500/2900

9.8/9.8

$112

-

3.5

360

S

117

133

EM18N34

17500/17200

13000/10600

230/208

7.4/8.0

2590/2550

19.5/17.0

4200/3500

8.6/8.6

$131

-

4.6

350

M

141

158

EM24N34

22300/22000

13000/10600

230/208

11.2/11.9

2590/2550

19.5/17.0

4200/3500

8.6/8.6

$207

-

10.0

390

M

153

166

EL36N35

36000/35700

17300/14300

230/208

19.0/20.5

4235/4200

24.0/22.4

5500/4650

8.5/8.5

$338

-

12.0

725

L

213

225

*Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 60° F to 115° F.

Kühl+ Heat Pump heating information (shown in red) indicates heat pump performance. Kühl+ and Chill+ Electric Heat heating information (shown in red) indicates electric heat strip performance. For Kühl+ Heat Pump electric heating performance refer to corresponding Kühl+ Electric Heat model.

As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® models meet the

ENERGY STAR®

Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.

R-410A

All models use

environmentally friendly R-410A refrigerant.

7

LISTED

 

Image 8
Contents Cool Only Heat PumpTable Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Repair Hazards Property Damage Hazards Model and Serial Number Location IntroductionComponents Identification Unit Identification Specifications Refrigeration System Performance DataKeep the filter clean Unit placementProper installation of seal gasket Provide good air flowFire Hazard Electrical DataElectric Shock Hazard Electrical Shock Hazard Kuhl Control Options FriedrichLink AdapterControl Panel and Display Identification Control Panel Operation Instructions Timer Schedule Button ºF ºC SelectDIM Function AlertsControl Panel Lock External Control StatusTo Turn On the Timer or Schedule Selected Timer or Schedule Options 1 or 2 SelectionTimer Start Time Timer SettingsSet theTimer Stop Time Timer on ScenariosTimer OFF Scenarios Timer Schedule Control BlockRemote Control Operation Remote Control Operation Unit Operation Front PanelElectronic Control Sequence of Operation Compressor OperationHeating Mode Control Operation Heat Control Heat Pump OnlyHeat Pump With Electric Heat Operation ConditionElectric Heat Operation in Cool with Electric Heat Units Compressor Lock Out Time Using ModeRemoving the Front Cover Replacing the Indoor Coil Thermistor Swing OutAir flow direction adjustment Fresh air and exhaust controlComponents Testing Capacitor Check with Capacitor AnalyzerCapacitor Connections FAN MotorTesting the Heating Element Electric Shock Hazard Heating ElementHeating Element Heat Pump Models Drain PAN ValveUser Interface Control Board Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressure410A Sealed Refrigeration System Repairs Refrigerant ChargingFreeze Hazard Method Of Charging / RepairsBurn Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Hermetic Components Check Capillary Tube SystemsReversing Valve DESCRIPTION/OPERATION Testing the Reversing Valve Solenoid Coil Reversing Valve in Heating ModeExplosion Hazard Procedure For Changing Reversing ValveTouch Test in Heating/Cooling Cycle Single Phase Connections Single Phase Running and L.R.A. TestLocked Rotor Voltage L.R.V. Test Determine L.R.VChecking Compressor Efficiency Single Phase Resistance TestGround Test Recommended procedure for compressor replacement High TemperaturesHigh Pressure Hazard Routine Maintenance Clearances Sleeve / DrainDecorative Front Cover Filter assembly Heat pumps operate differently Condensation is normalFrosting NoisesIf you require further assistance Our specialists are able to assist you withDC-2 Drain Kit Part No Carbon Filter KitsSee codes chart on next Error Codes and Alarm Status Test Mode Temp Room AIR Conditioner Unit Performance Test Data Sheet HOW is ALL of the INSTALLATION? Good BADJOB Name Techs Name = SQ/CU/FTTroubleshooting Tips Problem Possible Cause Possible SolutionTroubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Replace fuse, reset breaker. If repeats, check Possible Cause Possible Solution Problem Possible Cause Possible Solution Heat / Cool only Room AIR Conditioners Troubleshooting Tips Heat Pump Room AIR Conditioners Trouble Shooting Tips Problem Possible Cause ActionSystem Cools When Heating is Desired YESNormal Function of Valve Malfunction of ValveElectronic Control Board Components Identification Friedrich Electronic Control KIT Friedrich Model Prefix ContentsProcedure Schematic Part NO. REV 92170013 Kϋhl Electronic Control Cool only Models SL36N30-A Wiring Diagram Wiring Diagram 92170015 92170016 Kϋhl Electronic Control Heat Pump model YL24N35-A Need to Configure it. Follow the steps below to configure Air Conditioner Message Remote Control MessageAir Conditioning Unit Display Remote Control Display Replacement Instructions Parts Section Parts Section Kühl & Kühl+ Small-Chassis 2012 Parts List SHROUD, SML Kühl & Kühl+ Medium-Chassis 2012 Parts List SHROUD, MED Kühl & Kühl+ Large-Chassis 2012 Parts List Deck LRG Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty AAA Refrigeration Service Customer Satisfaction and Quality AssuranceFriedrich AIR Conditioning CO

SM18N30*, SS10N10*, SS15N30*, SS12N10*, SS14N10* specifications

Friedrich air conditioners, particularly models SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30*, are renowned for their reliable performance, innovative technologies, and user-friendly features. Designed for both residential and commercial use, these units stand out due to their energy efficiency, advanced cooling capabilities, and versatile operation.

One of the standout features across these models is their energy efficiency. Equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, they help users save on energy costs while reducing their carbon footprint. Specifically, the SS14N10* and SS12N10* models excel in cooling efficiency, ensuring that the spaces they occupy remain comfortably cool even in the hottest conditions. This not only contributes to lower energy bills but also promotes environmental sustainability.

The cooling technologies integrated into these units include advanced inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand of a room. As a result, these air conditioners maintain desired temperatures with minimal fluctuations, ensuring optimal comfort and significant energy savings. Models like SS15N30* and SM18N30* are particularly stellar in maintaining efficiency even during peak usage hours.

Moreover, these air conditioners are equipped with multi-stage filtration systems that enhance indoor air quality. The filters effectively capture dust, allergens, and other pollutants, resulting in cleaner and healthier air for occupants. This is especially important for individuals with allergies or respiratory issues.

User-friendly controls add another layer of convenience. Many models incorporate smart technology allowing users to control the units via mobile apps or home automation systems. This feature enables remote operation, scheduling, and real-time monitoring, making it easier to manage climate conditions effectively.

In terms of design, models like SS10N10* prioritize aesthetics without compromising functionality. They feature sleek, modern designs that seamlessly integrate into various decors, whether in a home or an office. Additionally, quiet operation technology reduces noise levels during functionality, enhancing comfort, particularly in bedrooms or quiet office environments.

Overall, Friedrich’s SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30* models embody the brand's commitment to innovation and customer satisfaction. Their blend of energy efficiency, advanced cooling technology, air quality enhancement, and smart controls positions them as leaders in the air conditioning market, catering to diverse cooling needs while promoting a sustainable future.