Friedrich SM18N30*, SS14N10*, SS12N10*, SS15N30*, SS10N10* service manual Shroud, Med

Page 89

Kühl & Kühl+ Medium-Chassis 2012 Parts List

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

Part Number

Part Description

EM18N34-A

EM24N34-A

SM15N10-A

SM18N30-A

SM21N30-A

SM24N30-A

YM18N34-A

 

 

17

61804901

SHROUD, MED

1

1

1

1

1

1

1

 

 

18

61804100

MOUNT, FAN MOTOR

1

1

1

1

1

1

1

 

 

19

61907212

INNERWALL ASY MED

1

1

1

1

1

1

1

 

 

20

61821500

ASSY DOOR/SLIDE S/M/L

1

1

1

1

1

1

1

 

 

*

61814805

CONNECTOR FRESH AIR S/M

1

1

1

1

1

1

1

 

 

21

61817100

DECK SML/MED

1

1

1

1

1

1

1

 

 

*

61817001

INSUL L/S PANEL MED

1

1

1

1

1

1

1

 

 

22

61820200

AIRFOIL SM/MED/SH

1

1

1

1

1

1

1

 

 

23

61816701

INSUL TOP COVER S/M

1

1

1

1

1

1

1

 

 

24

61906700

COVER TOP S/M

1

1

1

1

1

1

1

 

 

25

61817400

BLOWER FR MED

1

1

1

1

1

1

1

 

 

26

61816901

INSUL INNERWALL MED

1

1

1

1

1

1

1

 

 

27

61807256

PANEL CONTROL MED

1

1

1

1

1

1

1

 

 

28

61804310

ASSY PARTITION MED

1

1

1

1

1

1

1

 

 

29

61803461

BASEPAN

 

 

1

1

1

1

 

 

 

29

61803462

BASEPAN

1

1

 

 

 

 

1

 

 

30

61803800

DRAINPAN SML/MED

1

1

1

1

1

1

1

 

 

31

62400210

AIR FILTER ASSEMBLY MED

1

1

1

1

1

1

1

 

 

32

62400134

TOOL MANIFOLD

1

1

1

1

1

1

1

 

 

*

60301802

CLIP MANIFOLD TOOL

1

1

1

1

1

1

1

 

 

33

62400124

ASSY UI HOLDER MOUNT SML/MED

1

1

1

1

1

1

1

 

 

34

61802600

BRACE SHROUD, S/M

2

2

2

2

2

2

2

 

 

35

91400402

COMPRESSOR STUD

3

3

3

3

3

3

3

 

 

35

61715800

COUNTER WEIGHT

2

2

3

2

2

2

2

 

 

36

61028900

COMPRESSOR GROMMET

3

 

 

3

3

 

 

 

 

36

61028901

COMPRESSOR GROMMET

 

3

3

 

 

3

3

 

 

37

61937100

PANEL L/S MED

1

1

1

1

1

1

1

 

 

38

61816800

INSUL L/S AIR DECK S/M

1

1

1

1

1

1

1

 

 

39

62400426

DECORATIVE FRONT SERVICE KIT MED

1

1

1

1

1

1

1

 

 

40

61819817

ANGLE WNGBRD SIDE PAINTED MED

 

 

2

2

2

2

 

 

 

41

61109514

BRKT SUPPORT ASSY PAINTED

 

 

2

2

2

2

 

 

 

42

61819715

ANGLE WINGBOARD TOP PAINTED SML/MED

 

 

1

1

1

1

 

 

 

43

60610305

WINDOW SEAL GASKET

1

1

1

1

1

1

1

 

 

44

61717302

CHASSIS GASKET SEAL

1

1

1

1

1

1

1

 

 

45

61808414

SILL PLATE PAINTED SML/MED

1

1

1

1

1

1

1

 

 

46

61825721

SHELL OUTER MED REPLMT 2010

1

1

1

1

1

1

1

 

 

47

60294421

WINGBOARD MED 2010

 

 

1

1

1

1

 

 

 

48

62601015

REMOTE CONTROL SERVICE KIT

1

1

1

1

1

1

1

 

 

*

61824405

CHECK VALVE

 

 

 

 

 

 

1

 

 

*

61883102

48 PAD ISOLATION 3X6

 

 

 

 

 

 

1

 

 

*

61818900

HEATER MOUNT BRACKET

1

1

 

 

 

 

1

 

 

*

61812900

SHIELD BOTTOM S/M 3R

 

1

 

 

 

 

1

 

 

*

61812901

SHIELD BOTTOM S/M 4R

1

 

 

 

 

 

 

 

 

*

61821801

SHIELD HEAT MED

1

1

 

 

 

 

1

 

 

*

61715800

COUNTER WEIGHT

1

 

 

1

1

 

 

 

 

*

60846016

ASSY PLSTC BAG W/WIK

 

 

1

1

1

1

 

 

 

*

60846017

ASSY PLSTC BAG W/O WIK

1

1

 

 

 

 

1

 

 

*

60073300

GASKET URETHANE FOAM

 

 

1

1

1

1

 

 

 

*

61819601

SHELL GUIDE S/M/L

2

2

2

2

2

2

2

 

 

*

61826400

CHASSIS RETAINER WIRE

1

1

1

1

1

1

1

 

 

*

62601019

THERMISTOR SENSOR KIT

1

1

1

1

1

1

1

 

88

Image 89
Contents Heat Pump Cool OnlyTable Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Repair Hazards Property Damage Hazards Model and Serial Number Location IntroductionComponents Identification Unit Identification Refrigeration System Performance Data SpecificationsUnit placement Keep the filter cleanProper installation of seal gasket Provide good air flowFire Hazard Electrical DataElectric Shock Hazard Electrical Shock Hazard FriedrichLink Adapter Kuhl Control OptionsControl Panel and Display Identification Control Panel Operation Instructions ºF ºC Select Timer Schedule ButtonAlerts DIM FunctionControl Panel Lock External Control StatusTimer or Schedule Options 1 or 2 Selection To Turn On the Timer or Schedule SelectedTimer Settings Timer Start TimeTimer on Scenarios Set theTimer Stop TimeTimer Schedule Control Block Timer OFF ScenariosRemote Control Operation Remote Control Operation Front Panel Unit OperationCompressor Operation Electronic Control Sequence of OperationHeat Control Heat Pump Only Heating Mode Control OperationCondition Heat Pump With Electric Heat OperationElectric Heat Operation in Cool with Electric Heat Units Compressor Lock Out Time Mode UsingRemoving the Front Cover Swing Out Replacing the Indoor Coil ThermistorFresh air and exhaust control Air flow direction adjustmentCapacitor Check with Capacitor Analyzer Components TestingCapacitor Connections FAN MotorHeating Element Testing the Heating Element Electric Shock HazardHeating Element Heat Pump Models Drain PAN ValveUser Interface Control Board Refrigeration Sequence of Operation Refrigeration system under high pressure 410A Sealed System Repair ConsiderationsRefrigerant Charging 410A Sealed Refrigeration System RepairsFreeze Hazard Method Of Charging / RepairsBurn Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Capillary Tube Systems Hermetic Components CheckReversing Valve DESCRIPTION/OPERATION Reversing Valve in Heating Mode Testing the Reversing Valve Solenoid CoilExplosion Hazard Procedure For Changing Reversing ValveTouch Test in Heating/Cooling Cycle Single Phase Running and L.R.A. Test Single Phase ConnectionsLocked Rotor Voltage L.R.V. Test Determine L.R.VChecking Compressor Efficiency Single Phase Resistance TestGround Test High Temperatures Recommended procedure for compressor replacementHigh Pressure Hazard Routine Maintenance Clearances Sleeve / DrainDecorative Front Cover Filter assembly Condensation is normal Heat pumps operate differentlyFrosting NoisesOur specialists are able to assist you with If you require further assistanceDC-2 Drain Kit Part No Carbon Filter KitsSee codes chart on next Error Codes and Alarm Status Test Mode Temp HOW is ALL of the INSTALLATION? Good BAD Room AIR Conditioner Unit Performance Test Data SheetJOB Name Techs Name = SQ/CU/FTProblem Possible Cause Possible Solution Troubleshooting TipsTroubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Replace fuse, reset breaker. If repeats, check Possible Cause Possible Solution Problem Possible Cause Possible Solution Heat / Cool only Room AIR Conditioners Troubleshooting Tips Problem Possible Cause Action Heat Pump Room AIR Conditioners Trouble Shooting TipsYES System Cools When Heating is DesiredMalfunction of Valve Normal Function of ValveElectronic Control Board Components Identification Friedrich Electronic Control KIT Friedrich Model Prefix ContentsProcedure Schematic Part NO. REV 92170013 Kϋhl Electronic Control Cool only Models SL36N30-A Wiring Diagram Wiring Diagram 92170015 92170016 Kϋhl Electronic Control Heat Pump model YL24N35-A Air Conditioner Message Remote Control Message Need to Configure it. Follow the steps below to configureAir Conditioning Unit Display Remote Control Display Replacement Instructions Parts Section Parts Section Kühl & Kühl+ Small-Chassis 2012 Parts List SHROUD, SML Kühl & Kühl+ Medium-Chassis 2012 Parts List SHROUD, MED Kühl & Kühl+ Large-Chassis 2012 Parts List Deck LRG Schedule Table with Energy Saving Values AddendumRoom AIR Conditioners Limited Warranty Customer Satisfaction and Quality Assurance AAA Refrigeration ServiceFriedrich AIR Conditioning CO

SM18N30*, SS10N10*, SS15N30*, SS12N10*, SS14N10* specifications

Friedrich air conditioners, particularly models SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30*, are renowned for their reliable performance, innovative technologies, and user-friendly features. Designed for both residential and commercial use, these units stand out due to their energy efficiency, advanced cooling capabilities, and versatile operation.

One of the standout features across these models is their energy efficiency. Equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, they help users save on energy costs while reducing their carbon footprint. Specifically, the SS14N10* and SS12N10* models excel in cooling efficiency, ensuring that the spaces they occupy remain comfortably cool even in the hottest conditions. This not only contributes to lower energy bills but also promotes environmental sustainability.

The cooling technologies integrated into these units include advanced inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand of a room. As a result, these air conditioners maintain desired temperatures with minimal fluctuations, ensuring optimal comfort and significant energy savings. Models like SS15N30* and SM18N30* are particularly stellar in maintaining efficiency even during peak usage hours.

Moreover, these air conditioners are equipped with multi-stage filtration systems that enhance indoor air quality. The filters effectively capture dust, allergens, and other pollutants, resulting in cleaner and healthier air for occupants. This is especially important for individuals with allergies or respiratory issues.

User-friendly controls add another layer of convenience. Many models incorporate smart technology allowing users to control the units via mobile apps or home automation systems. This feature enables remote operation, scheduling, and real-time monitoring, making it easier to manage climate conditions effectively.

In terms of design, models like SS10N10* prioritize aesthetics without compromising functionality. They feature sleek, modern designs that seamlessly integrate into various decors, whether in a home or an office. Additionally, quiet operation technology reduces noise levels during functionality, enhancing comfort, particularly in bedrooms or quiet office environments.

Overall, Friedrich’s SS14N10*, SS12N10*, SS15N30*, SS10N10*, and SM18N30* models embody the brand's commitment to innovation and customer satisfaction. Their blend of energy efficiency, advanced cooling technology, air quality enhancement, and smart controls positions them as leaders in the air conditioning market, catering to diverse cooling needs while promoting a sustainable future.