TROUBLESHOOTING & REPAIR |
|
| |||
TROUBLESHOOTING GUIDE |
| Observe Safety Guidelines | |||
| detailed in the beginning of this manual. | ||||
|
|
| |||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |||
|
|
|
|
| |
| OUTPUT PROBLEMS |
|
|
| |
The engine starts and runs at the | 1. Check the welding cables for | 1. Check the fine current control | |||
correct speed but there is no, or | loose or faulty connections. | field rheostat for resistance and | |||
very low, welder output. The DC | 2. Check for loose or missing | proper operation. Normal resis- | |||
auxiliary output voltage is normal. | tance is 64 ohms. Check asso- | ||||
brushes in the welding genera- | |||||
| ciated wires for loose or faulty | ||||
| tor. | ||||
| connections. | See the Wiring | |||
|
| ||||
|
| Diagram. |
|
| |
|
| 2. Perform the Main Generator | |||
|
| Shunt Field Winding Test. | |||
|
| 3. Check the continuity of the inter- | |||
|
| pole coils. They should show | |||
|
| continuity from the positive | |||
|
| brusholders to the positive out- | |||
|
| put terminal and should NOT be | |||
|
| grounded to | the generator | ||
|
| frame. |
|
| |
|
| 4. Check the continuity of the | |||
|
| series coils. They should show | |||
|
| continuity from the negative | |||
|
| brusholders, through the current | |||
|
| selector switch, to the negative | |||
|
| output terminal and should NOT | |||
|
| be grounded to the generator | |||
|
| frame. |
|
| |
|
| 5. The main armature may be | |||
|
| faulty. Check for grounds and/ | |||
|
| or shorts. |
|
| |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call