TROUBLESHOOTING & REPAIR | |||
Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE |
detailed in the beginning of this manual. |
|
| |
|
|
| |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |
|
|
| |
| OUTPUT PROBLEMS |
| |
The actual welding current is much | 1. Check the main DC generator | 1. The engine operating speed | |
greater than is indicated on the | brushes for good commutation | may be too high. If necessary | |
dials. | and alignment. | Contact the | perform the Engine Throttle |
| Lincoln Electric | Service Dept. | Adjustment Test. |
| 2. While the machine is loaded, | ||
|
|
| |
|
|
| check the series coils for signs |
|
|
| of “arcing.” This condition could |
|
|
| point to shorted turns in the |
|
|
| series coils. |
|
|
| 3. Perform the DC Exciter Test. |
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call