TROUBLESHOOTING & REPAIR | ||||||
TROUBLESHOOTING GUIDE |
|
|
| Observe Safety Guidelines | ||
|
|
| detailed in the beginning of this manual. | |||
|
|
|
|
| ||
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| ||
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
|
|
|
|
|
|
|
|
| FUNCTION PROBLEMS |
|
|
|
|
|
|
| |||
No control of arc voltage. Wire feed- | 1. The arc voltage control poten- | 1. | The arc voltage control poten- | |||
ing is normal. |
|
| tiometer may be dirty. Rotate |
| tiometer may be faulty. Check or | |
|
|
| several times and check if prob- |
| replace. See Wiring Diagram. | |
|
|
| lem is resolved. |
|
|
|
|
|
|
| 2. | Perform the SCR Rectifier | |
|
|
|
|
| Assembly Tests. |
|
|
|
|
| 3. | The control board may be faulty. | |
|
|
|
|
| Replace. |
|
|
|
|
| |||
There is no gas flow when gun trig- | 1. Check gas source and hoses for | 1. | Check the gas solenoid by dis- | |||
ger is pulled. Wire feeds and weld |
| leaks or kinks. |
| connecting it from the control | ||
voltage is present. |
|
|
|
| board (Plug J8) and applying a | |
|
|
|
|
| 12 VDC external supply to the | |
|
|
|
|
| gas solenoid. If the solenoid | |
|
|
|
|
| does NOT activate then it may | |
|
|
|
|
| be faulty. Replace. |
|
|
|
|
| 2. | The control broad may be faulty. | |
|
|
|
|
| Replace. |
|
|
|
|
|
| ||
The machine stops feeding wire | 1. | Check for adequate wire supply. | 1. | Check the motor armature cur- | ||
while welding. |
|
|
|
| rent. Normal armature current is | |
|
| 2. | Check for mechanical restric- |
| 2.0 to 2.7 amps maximum. | If |
|
|
| tions in the wire feeding path. |
| the motor armature current is | |
|
|
| The gun may be clogged. |
| normal the control board may be | |
|
|
|
|
| faulty. Replace. |
|
|
| 3. Check gun liner and tip are cor- |
|
|
| |
|
|
| rect for wire size being used. | 2. | If the motor armature current is | |
|
|
|
|
| high (over 2.7 amps) and there | |
|
| 4. Check spindle for ease of rota- |
| are NO restrictions in the wire | ||
|
|
| tion. |
| feeding path then the motor or | |
|
|
|
|
| gear box may be defective. | |
|
| 5. If Timer Option Kit is installed, |
| Replace. |
| |
|
|
| make sure spot timer knob is set |
|
|
|
|
|
| to OFF. |
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call