TROUBLESHOOTING & REPAIR |
ABNORMAL OPEN CIRCUIT VOLTAGE
OUTPUT CAPACITOR BANK NOT FUNCTIONING
0 VOLTS
20.0 V | 5 ms |
| SCOPE SETTINGS |
|
|
|
|
This is NOT the typical DC output voltage |
|
|
waveform. The output capacitors are not | Volts/Div | 20 V/Div |
functioning. Note the lack of “filtering” in the |
|
|
output waveform. The output capacitor bank | Horizontal Sweep | 5 ms/Div |
was disconnected. Each vertical division |
|
|
represents 20 volts and each horizontal divi- | Coupling | . . . . DC |
sion represents 5 milliseconds in time. |
|
|
NOTE: Scope probes connected at machine | Trigger | . Internal |
|
| |
output terminals: (+) probe to electrode, |
|
|
probe to work. |
|
|
|
|
|