Return to Section TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR |
MAIN TRANSFORMER AND OUTPUT CHOKE
REMOVAL AND REPLACEMENT (continued)
FIGURE F.17 — MAIN TRANSFORMER REMOVAL.
Return to Section TOC
Return to Master TOC
LEAD
X1
OUTPUT
CHOKE POSITIVE
LEAD
OUTPUT
CHOKE
LEAD
NOTE:
LEAD X4
LEADS
X2 AND X3
Section TOC
Master TOC
MAIN
TRANSFORMER
POWER
ENHANCEMENT
CHOKE
Return to
Return to Section TOC
Return to
Return to Master TOC
PROCEDURE
1.Disconnect main input power to the machine.
2.Remove the case side panels using a 3/8 in. nutdriver.
3.Test that the capacitors are discharged using a volt ohmmeter. Polarity must be observed.
4.Remove lead X1 from the left side SCR heat sink assembly using a 1/2 in. sock- et wrench, extender and universal adapter. See Figure F.17.
5.Remove lead X4 from the right side heat sink assembly using a 1/2 in. sock- et wrench, extender and universal adapter.
6.Remove the two transformer secondary leads X2 and X3 (braided copper strap) from the negative capacitor bank buss bar using two 1/2 in. open end wrench- es.
7.Disconnect and label all transformer leads from the reconnect panel using a 3/8 in. open end wrench.
8.Disconnect and label all leads from the input power switch.
9.Remove the power switch.
10.Disconnect thermostat leads #320 and #320B from the SCR Rectifier.