Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR |
ACTIVE SCR RECTIFIER ASSEMBLY TEST (continued)
FIGURE F.6 — CONTROL BOARD MOLEX PLUG LOCATIONS FOR G3521 PC CONTROL BOARD.
J6
J5
J3
J8 | J9 |
J1
J4
J2
Return to Section TOC
Return to Master TOC
TEST PROCEDURE
1.Disconnect main AC input power to the machine.
2.Remove the case top and side panels with a 3/8 in. nutdriver.
3.Remove the tool tray with a 5/16 in. nut- driver.
4.Verify that the capacitors have completely discharged with a volt- ohmmeter.
5.Disconnect plugs J6 from the G3521 control board and J9 from the M19248 snubber PC board. This electrically isolates the SCR bridge assembly. See Figure F.6.
Return to Section TOC
Return to Master TOC