| TROUBLESHOOTING & REPAIR |
|
|
|
|
| ||||||
| Observe Safety Guidelines |
|
|
|
| TROUBLESHOOTING GUIDE | ||||||
| detailed in the beginning of this manual. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |||||||
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| |||||||
| (SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |||||||||
|
|
|
|
|
|
|
|
|
| |||
|
| OUTPUT PROBLEMS |
|
|
|
|
|
|
| |||
| The machine has minimum (or very | 1. Make certain the | 1. | Check the Output Control (R1) | ||||||||
| low) welding output and no con- | input voltage is correct and |
| and associated wiring. See the | ||||||||
| trol. | matches the rating plate and |
| Wiring Diagram. |
|
|
| |||||
|
| the reconnect panel. |
| 2. Check the Output Control | ||||||||
|
|
|
|
|
| |||||||
|
| 2. Make certain the Dial Control |
| Switch | (S2) | and | associated | |||||
|
| Switch (SW3) is in the correct |
| wiring. | See | the | Wiring | |||||
|
| position. | (Not present on R3R |
| Diagram. |
|
|
|
| |||
|
| 300). |
|
|
| 3. Perform the Main Transformer | ||||||
|
|
|
|
|
| |||||||
|
| 3. If the remote control is being |
| Test. |
|
|
|
|
| |||
|
| used, set the Output | Control | 4. | Perform | the | SCR/Diode | |||||
|
| Switch (SW2) to the Machine or | ||||||||||
|
|
| Rectifier Bridge Test. |
|
| |||||||
|
| Local position and control the |
|
|
| |||||||
|
|
|
|
|
|
|
|
| ||||
|
| weld output with the machine | 5. If the Pocket Amptrol is not | |||||||||
|
| Output Control (R1). | If the |
| functioning | properly, | perform | |||||
|
| problem is resolved, check the |
| the Pocket | Amptrol | Circuit | ||||||
|
| remote control unit and associ- |
| Test. |
|
|
|
|
| |||
|
| ated cable leads. If the Pocket | 6. | The control | board | may be | ||||||
|
| Amptrol option is being used, | ||||||||||
|
|
| faulty. Replace. |
|
|
| ||||||
|
| the Pocket Amptrol circuit may |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| ||||
|
| be faulty. |
|
|
|
|
|
|
|
|
|
|
|
| 4. Make sure the remote control |
|
|
|
|
|
|
| |||
|
| leads (#75, #76, #77) are not |
|
|
|
|
|
|
| |||
|
| grounded or shorted to the |
|
|
|
|
|
|
| |||
|
| positive | or negative | welding |
|
|
|
|
|
|
| |
|
| output. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| The input contactor operates - the | 1. Make certain the output control | 1. | Check for loose or faulty con- | ||||||||
| fan runs - the pilot light is on - but | switch (SW2) is in the Machine |
| nections on the heavy current | ||||||||
| the machine has no welding out- | or Local position. | If the prob- |
| carrying leads between the out- | |||||||
| put. The open circuit voltage is not | lem is resolved, check the |
| put terminals, the shunt, the | ||||||||
| present at the output terminals. | remote control and associated |
| choke | and | the | SRC/Diode | |||||
|
| circuitry. | See | the | Wiring |
| Bridge. | See | the | Wiring | ||
|
| Diagram. |
|
|
|
| Diagram. |
|
|
|
| |
|
|
|
|
|
| 2. | Perform | the | SCR/Diode | |||
|
|
|
|
|
|
| Rectifier Bridge Test. |
|
| |||
|
|
|
|
|
| 3. Perform the Main Transformer | ||||||
|
|
|
|
|
|
| Test. |
|
|
|
|
|
|
|
|
|
|
| 4. The control board may be | ||||||
|
|
|
|
|
|
| faulty. Replace. |
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call