Return to Section TOC
Return to Master TOC
INSTALLATION
TECHNICAL SPECIFICATIONS - IDEALARC R3R-300
INPUT - THREE PHASE ONLY
Standard Voltage | Input Current @ Rated Output |
230V | 56A |
460V | 28A |
Return to Section TOC
Return to Master TOC
Duty Cycle
100%
60%
35%
RATED OUTPUT
Amps
230
300
375
OUTPUT
Volts at Rated Amps
29
32
35
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Current Range | Maximum Open Circuit Voltage |
45 to 375 Amps | 67 VDC |
| RECOMMENDED INPUT WIRE AND FUSE | SIZES AT 60% DUTY CYCLE |
| |||||||
|
|
|
|
|
|
| Input Wire Size | Ground Wire Size |
| |
| Input Voltage / |
| Fuse | Input Ampere |
| Type 75°C | Type 75°C |
| ||
| Frequency | (Super Lag) | Rating on |
| Copper Wire in | Copper Ground |
| |||
|
| or Breaker Size | Nameplate |
| Conduit | Wire in Conduit |
| |||
| Volts/Hz |
|
|
|
|
| AWG (IEC) Sizes | AWG (IEC) Sizes |
| |
230/60 | 80 | 56 |
|
| 8 (10 mm2) | 8 (10 mm2) |
| |||
460/60 | 40 | 28 |
|
| 10 (6 mm2) | 10 (6 mm2) |
| |||
|
|
|
|
|
|
|
|
|
| |
|
|
| PHYSICAL | DIMENSIONS |
|
|
| |||
| Height |
| Width |
|
|
| Depth |
| Weight |
|
| 27.50 in. |
| 22.25 in. |
|
| 33.10 in. |
| 350 lbs. |
| |
| (700 mm) |
| (565 mm) |
|
| (840 mm) |
| (159 kg) |
| |
|
|
|
|
|
|
|
|
|
|
|
IDEALARC R3R