Lincoln Electric R3R-500, R3R-300 service manual Technical Specifications Idealarc R3R-400

Page 9

Return to Section TOC

Return to Master TOC

A-3

A-3

INSTALLATION

TECHNICAL SPECIFICATIONS - IDEALARC R3R-400

INPUT - THREE PHASE ONLY

Standard Voltage

Input Current @ Rated Output

230V

74A

460V

37A

Return to Section TOC

Return to Master TOC

Duty Cycle

100%

60%

35%

RATED OUTPUT

Amps

300

400

500

OUTPUT

Volts at Rated Amps

32

36

40

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Current Range

Maximum Open Circuit Voltage

60 to 500 Amps

67 VDC

 

RECOMMENDED INPUT WIRE AND FUSE

SIZES AT 60% DUTY CYCLE

 

 

 

 

 

 

 

 

Input Wire Size

Ground Wire Size

 

 

Input Voltage /

 

Fuse

Input Ampere

 

Type 75°C

Type 75°C

 

 

Frequency

(Super Lag)

Rating on

 

Copper Wire in

Copper Ground

 

 

 

or Breaker Size

Nameplate

 

Conduit

Wire in Conduit

 

 

Volts/Hz

 

 

 

 

 

AWG (IEC) Sizes

AWG (IEC) Sizes

 

230/60

125

74

 

 

6 (16 mm2)

6 (16 mm2)

 

460/60

60

37

 

 

10 (6 mm2)

10 (6 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL

DIMENSIONS

 

 

 

 

Height

 

Width

 

 

 

Depth

 

Weight

 

 

27.50 in.

 

22.25 in.

 

 

33.10 in.

 

402 lbs.

 

 

(700 mm)

 

(565 mm)

 

 

(840 mm)

 

(182 kg)

 

 

 

 

 

 

 

 

 

 

 

 

IDEALARC R3R

Image 9
Contents Idealarc R3R-300, -400 California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation Section Technical Specifications Idealarc R3R-300 InstallationTechnical Specifications Idealarc R3R-400 Technical Specifications Idealarc R3R-500 Select Suitable Location Safety PrecautionsLifting TiltingInput Connections Ground ConnectionInput Supply Connections Figure A.2 Input Power Supply Connections Input Wire and Fuse SizeInput Supply Connection Diagram Reconnect ProcedureReturn to Section Output Connections STICK, TIG, AIR/CARBON ARC CuttingIdealarc R3R Table of Contents Operation Section Safety Instructions OPERATIONB-2Operating Instructions Operation Design Features and AdvantagesGeneral Description Recommended ProcessesFigure B.1 Case Front Controls Controls and SettingsOperation Operating Steps Welding OperationTable of Contents Accessories Section OPTIONS/ACCESSORIES AccessoriesFactory Installed Options Field Installed OptionsTable of Contents Maintenance Section Routine and Periodic Maintenance MaintenanceFigure D.1 General Component Locations Idealarc R3R Table of Contents Theory of Operation Section Input Line Voltage Contactor and Main Transformer Theory of OperationFigure E.3 Output RECTIFICATION, CONTROL, and Feedback Output Rectification CONTROL, and FeedbackOptional Polarity Switch and Pocket Amptrol Circuits Protective Devices and Circuits Figure E.5 SCR Operation SCR OperationTable of Contents Troubleshooting & Repair Section HOW to USE Troubleshooting Guide Troubleshooting & RepairPC Board can be damaged by static electricity PC Board Troubleshooting ProceduresOutput Problems Troubleshooting GuideSCR/Diode Pocket Amptrol Circuit Input Contactor Output Problems Welding Problems Materials Needed DescriptionInput Contactor Test Test ProcedureRemoved Test for Contact Continuity Description Figure F.3 DC Coil Input Contactor Connections Removed Control Transformer T2 Voltage Test Figure F.5 Control Transformer and Lead Locations Control Transformer T2 Voltage TestTroubleshooting & Repair Main Transformer T1 Voltage Test Main Transformer T1 Voltage Test Figure F.8 Main Secondary Lead Test Points Table F.1 Phase Angle Winding TestFigure F.9 Control Board G2206 Test Points Static SCR/DIODE Rectifier Bridge Test Static SCR/DIODE Rectifier Bridge Test Figure F.13 Snubber Board M15370 Plug P5 Location Static SCR/DIODE Rectifier Bridge TestSCR Test Active SCR Test Active SCR Test Figure F.20 SCR Tester Circuit and SCR Connections Active SCR TestPocket Amptrol Circuit Test Figure F.21 T3 Transformer and Leads Pocket Amptrol Pocket Amptrol Circuit TestFigure F.22 Pocket Amptrol Board Plug P6 and P7 Location Figure F.23 Sensing Resistor R4 Maximum Output Setting no Load Scope SettingsNormal Open Circuit Voltage Waveform Typical Output Voltage Waveform Machine Loaded CH1 Typical SCR Gate Voltage WaveformONE Output SCR not Functioning Abnormal Output Voltage WaveformInput Contactor CR1 CLEANING/REPLACEMENT Input Contactor CR1 CLEANING/REPLACEMENT Cleaning ProcedureContactor Replacement Procedure FAN Motor and Blade Removal and Replacement Procedure FAN Motor and Blade Removal and ReplacementSCR/DIODE Rectifier Assembly Removal and Replacement Removal and Replacement SCR/DIODE Rectificer AssemblyReassembly TroubleshootingSCR Removal and Replacement Special Instructions SCR Removal and ReplacementFigure F.29 1/2 Wide Leaf Spring Procedure for the 1/2 Inch Wide SpringClamping Procedure For 1/4-20 CAP Screws Clamping Procedure For 1/4-28 CAP ScrewsInch Wide Spring Procedure forAfter Replacing the SCRs Mounting of Stud Type Diodes to Aluminum Heat Sinks Heat Sinks Mounting of Stud Type Diodes to AluminumMain Transformer Removal and Replacement Removal of Lift Bail Main Transformer Removal & ReplacementFigure F.34 Choke Removal Removal of Choke and TOP Iron AssemblyFigure F.35 Epoxy MIX Application Areas Reassembly of Transformer CoilsFigure F.36 Coil Lead Placement Figure F.38 Secondary Lead Trim and Weld Detail Reassemble the Lift Bail Reassembling the Main Transformer Into the MachineInput Idle Amps and Watts Retest After Repair R3ROpen Circuit Voltages Welding Output Load TestWelding Output Terminals 63/69VDC 61/66VDC Welding Output Terminals 64/72VDC 61/69VDC Idealarc R3R Electrical Diagrams Idealarc R3R Electrical Diagrams DIAGRAMSELECTRICALG-4 Idealarc R3R-400, 500-I, 500 & 600-I Wiring Diagram Pocket Amptrol Schematic Snubber Board Schematic & Layout R3R-300 Control PC Board R3R-400 Control PC Board R3R-500 Control PC Board