Lincoln Electric IM10030 manual PRE-OPERATION Service, Gasoline Fuel only, BATTERY Connections

Page 10

A-3

INSTALLATION

A-3

 

 

 

3.Proper placement of the equipment on the trailer to insure stability side to side and front to back when being moved and when standing by itself while being operated or serviced.

4.Typical conditions of use, i.e., travel speed; rough- ness of surface on which the trailer will be operated; environmental conditions.

5.Conformance with federal, state and local laws(1)

(1)Consult applicable federal, state and local laws regarding specific requirements for use on public highways.

VEhICLE MOUNTING

WARNING

Improperly mounted concentrated loads may cause unstable vehicle handling and tires or other components to fail.

Only transport this Equipment on serviceable vehicles which are rated and designed for such loads.

Distribute, balance and secure loads so vehicle is stable under conditions of use.

Do not exceed maximum rated loads for compo- nents such as suspension, axles and tires.

Mount equipment base to metal bed or frame of vehicle.

Follow vehicle manufacturer’s instructions.

------------------------------------------------------------------------

PRE-OPERATION SERVICE

CAUTION

READ the engine operating and maintenance instructions supplied with this machine.

WARNING

FUEL

Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel sight gauge in the base of the machine while filling to prevent overfilling.

WARNING

Damage to the fuel tank may cause fire or explosion. Do not drill holes in the RANGER® 3 PhASE base or weld to the RANGER® 3 PhASE

base.

-----------------------------------------------------------------------

OIL

LUBRICATION  SYSTEM  CAPACITY

(INCLUDING  FILTER) Kohler CH23S - 2.0 Quarts (1.9 Liters)

The RANGER® 3 PHASE is shipped with the engine crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. Make cer- tain that the oil filler cap is tightened securely. Refer to the engine Owner’s Manual for specific oil recommen- dations.

bATTERY CONNECTIONS

CAUTION

Use caution as the electrolyte is a strong acid that can burn skin and damage eyes.

------------------------------------------------------------------------

This welder is shipped with the negative battery cable disconnected. Make sure that the Engine Switch is in the “STOP” position and attach the disconnected

GASOLINE

can cause fire or explosion.

Stop engine while fueling.

Do not smoke when fueling.

Keep sparks and flame away from tank.

Do not leave unattended while fueling.

Wipe up spilled fuel and allow fumes to clear before starting engine.

Do not overfill tank, fuel expan- sion may cause overflow.

cable securely to the negative battery terminal before attempting to operate the machine. If the battery is discharged and does not have enough power to start the engine, see the battery charging instructions in the Battery section.

NOTE: This machine is furnished with a wet charged battery; if unused for several months, the battery may require a booster charge. Be careful to charge the bat- tery with the correct polarity.

GASOLINE FUEL ONLY

------------------------------------------------------------------------

RANGER® 3 PhASE

Image 10
Contents Ranger 3 Phase Safety Depends on YouSafety California Proposition 65 WarningsSafety Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Receptacles InstallationAIR Cleaner Engine Idler Muffler Engine Protection Valve Lifters Fuel System GovernorSpark Arrester Safety PrecautionsTowing Gasoline Fuel only PRE-OPERATION ServiceBATTERY Connections GasolineLifting Additional Safety PrecautionAngle of Operation Muffler Outlet PipeInstructions Connection of Lincoln Electric Wire FeedersAdditional Safety Precautions Location / VentilationWelder Output Auxiliary PowerWelder Operation 120/240 Volt Dual Voltage ReceptacleMotor Starting Ground WireType Common Electrical Devices Possible Concerns Simultaneous Welding and Power Auxiliary Power WhILE WeldingSTANDbY Power Connections Connection of Ranger 3 PhASE to Premises Wiring Figure A.1GENERAL DESCRIPTION Engine SWITChOperation Welder Controls Function and OperationRanger 3 PhASE Approximate Fuel Consumption Control DialStopping ThE Engine STARTING/ShUTDOWN InstructionsBREAK-IN Period Running PERIODS. Remove Loads and Allow Engine toStick Constant Current Welding Welding ProcessTypical Current Ranges 1 for Tungsten ELECTRODES2 SCRATCh Start TIG Constant Current WeldingProcess Used Mode Welding Wire Feed Welding Processes Constant VoltageElectrode Current Range Setting ARC GougingAccessories Optional Equipment Field InstalledStick WIRE FEEDRECOMMENDED EQUIPMENT TIGRoutine Maintenance MaintenanceSafety Precautions Engine OIL ChANGEAIR Cleaner and OThER Maintenance OIL Filter ChANGEEngine Maintenance Parts Engine AdjustmentsSlip Rings TROUbLEShOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionTROUbLEShOOTING Diagrams Diagrams Dimension Print M22327Ranger 3 PhASE Precaucion Warnung