Lincoln Electric IM10030 manual Accessories, Optional Equipment Field Installed

Page 22

C-1

ACCESSORIES

C-1

 

 

 

OPTIONAL EQUIPMENT (Field Installed)

K2635-1 SMALL TWO-WhEEL ROAD TRAILER WITh DUO-hITCh-Forheavy-duty road, off-road, plant and yard use.

Includes pivoting jack stand, safety chains, and 13" wheels. Overall width 60". Stiff .120" welded rectangu- lar steel tube frame construction is phosphate etched and powder coat painted for superior rust and corro- sion resistance.

Low sway suspension gives outstanding stability with manageable tongue weight. Wheels bearings are packed with high viscosity, high pressure, low washout Lubriplate® grease.

Features a Duo-Hitch™ - a 2" Ball/Lunette Eye combi- nation hitch.

Order:

K2635-1 Trailer

K2639-1 Fender and Light Kit

K2640-1 Cable Rack

K1737-1 FOUR WhEEL ALL-TERRAIN UNDER- CARRIAGE - For moving by hand at construction sites. Heavy duty puncture resistant pneumatic tires.

K1770-1 UNDERCARRIAGE (FACTORY) - For mov- ing by hand on a smooth surface. One or two gas cylinders can be mounted on the rear of the undercar- riage with the installation of K1745-1 Cylinder Holder(s). Heavy duty puncture resistant pneumatic tires and front caster.

K1745-1 WELDING GAS CYLINDER LPG TANK hOLDER

Holds Welding Gas Cylinder for use on K1770-1 Undercarriage. One or two may be installed on an undercarriage.

K1788-1 ROLL CAGE - Gives added damage protection. Attaches to K1737-1, K1770-1, and K957-1.

K886-2 Canvas Cover -To protect the RANGER® 3 PHASE when not in use. Made from attractive red canvas material which is flame retardant, mildew resistant, and water repellent.

K802R Power Plug Kit - provides four 120V plugs rated at 15 amps each and one dual voltage, Full KVA plug rated at 120/240V, 50 amps.

K802N Power Plug Kit - Provides four 120V plugs rated at 20 amps each and one dual voltage, full KVA plug rated at 120/240V, 50 amps.

K704 Accessory Kit - Includes 35 ft (10.7m) 2/0 AWG elec- trode cable, 30 ft. (9.1m) 2/0 AWG work cable, headshield with No. 12 filter, GC300 work clamp and Cooltong® 300 electrode holder. Cables are rated at 300 amps, 100% duty cycle.

K875 Accessory Kit - For Stick welding. Includes 20ft.(6.1m) #6 electrode cable with lug. 15ft.(4.6m) #6 work cable with lugs, headshield, filter plate, work clamp, elec- trode holder and sample pack of mild steel electrode. 150 amp capacity.

K1898-1 Spark Arrester Kit - Attaches between muffler and exhaust elbow. Virtually eliminates spark emissions.

K1690-1 GFCI RECEPTACLE KIT - Includes one UL approved 120V ground fault circuit interrupter duplex type receptacle with cover and installation instructions. Replaces the factory installed 120V duplex receptacle. Each receptacle of the GFCI Duplex is rated at 20 Amps, the maximum total current from the GFCI Duplex is limit- ed to the 20 Amps. Two kits are required.

K1816-1 FULL KVA ADAPTER KIT - Plugs into the 120/240V NEMA 14-50R receptacle on the case front (which accepts 4-prong plugs) and converts it to a NEMA 6- 50R receptacle, (which accepts 3-prong plugs.)

T12153-9Full-KVA Power Plug - One dual voltage plug rated at 120/240V, 50 amps.

RANGER® 3 PhASE

Image 22
Contents Ranger 3 Phase Safety Depends on YouSafety California Proposition 65 WarningsSafety Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Receptacles InstallationAIR Cleaner Engine Idler Muffler Engine Protection Valve Lifters Fuel System GovernorSpark Arrester Safety PrecautionsTowing Gasoline Fuel only PRE-OPERATION ServiceBATTERY Connections GasolineLifting Additional Safety PrecautionAngle of Operation Muffler Outlet PipeInstructions Connection of Lincoln Electric Wire FeedersAdditional Safety Precautions Location / VentilationWelder Output Auxiliary PowerWelder Operation 120/240 Volt Dual Voltage ReceptacleMotor Starting Ground WireType Common Electrical Devices Possible Concerns Simultaneous Welding and Power Auxiliary Power WhILE WeldingSTANDbY Power Connections Connection of Ranger 3 PhASE to Premises Wiring Figure A.1GENERAL DESCRIPTION Engine SWITChOperation Welder Controls Function and OperationRanger 3 PhASE Approximate Fuel Consumption Control DialStopping ThE Engine STARTING/ShUTDOWN InstructionsBREAK-IN Period Running PERIODS. Remove Loads and Allow Engine toStick Constant Current Welding Welding ProcessTypical Current Ranges 1 for Tungsten ELECTRODES2 SCRATCh Start TIG Constant Current WeldingProcess Used Mode Welding Wire Feed Welding Processes Constant VoltageElectrode Current Range Setting ARC GougingAccessories Optional Equipment Field InstalledStick WIRE FEEDRECOMMENDED EQUIPMENT TIGRoutine Maintenance MaintenanceSafety Precautions Engine OIL ChANGEAIR Cleaner and OThER Maintenance OIL Filter ChANGEEngine Maintenance Parts Engine AdjustmentsSlip Rings TROUbLEShOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionTROUbLEShOOTING Diagrams Diagrams Dimension Print M22327Ranger 3 PhASE Precaucion Warnung