Lincoln Electric IM10030 manual Ranger 3 PhASE Approximate Fuel Consumption, Control Dial

Page 18

b-2

OPERATION

b-2

 

 

 

RANGE” SWITCh

 

The “Range” switch is used to select one of four amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range.

 

Process

Range Setting

 

Current Range

 

 

 

 

 

 

 

 

 

 

 

 

STICK/TIG

90 Max.

 

40 to 90 Amps

(constant current)

145 Max.

 

70 to 145 Amps

(3 range settings)

225 MAX

 

120 to 225 Amps

 

 

 

 

 

 

 

WIRE FEED

 

 

 

 

(constant voltage)

15 to 25V

 

Up to 200 Amps

(1 range setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

Never change the “RANGE” Switch setting while welding. This will damage the switch.

------------------------------------------------------------------------

CONTROL” DIAL

Provides a fine welding current adjustment within the Range Switch settings in the STICK mode and weld- ing voltage control with the Range switch set in the wire feed mode.

RANGER® 3 PhASE APPROXIMATE FUEL CONSUMPTION

 

KOhLER

 

23 h.P. COMMAND Ch23S

 

 

Low Idle - No Load

.40 Gallons/Hour

2400 RPM

(1.50 Liters/Hour)

High Idle - No Load

.7 Gallons/Hour

3700 RPM

(2.8 Liters/Hour)

DC CC Weld Output

1.3 Gallons/Hour

210 Amps @ 25 Volts

(4.9 Liters/Hour)

DC CV Weld Output

1.2 Gallons/Hour

200 Amps @ 20 Volts

(4.5 Liters/Hour)

 

 

Auxiliary Power Single Phase

1.52 Gallons/Hour)

9500 Watts

(5.77 Liters/Hour)

Auxiliary Power 3 Phase

1.64 Gallons/Hour)

10,500 Watts

(6.23 Liters/Hour)

 

 

RANGER® 3 PhASE

Image 18
Contents Ranger 3 Phase Safety Depends on YouSafety California Proposition 65 WarningsSafety Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Receptacles InstallationAIR Cleaner Engine Idler Muffler Engine Protection Valve Lifters Fuel System GovernorSafety Precautions Spark ArresterTowing Gasoline Fuel only PRE-OPERATION ServiceBATTERY Connections GasolineLifting Additional Safety PrecautionAngle of Operation Muffler Outlet PipeInstructions Connection of Lincoln Electric Wire FeedersAdditional Safety Precautions Location / VentilationWelder Output Auxiliary PowerWelder Operation 120/240 Volt Dual Voltage ReceptacleGround Wire Motor StartingType Common Electrical Devices Possible Concerns Auxiliary Power WhILE Welding Simultaneous Welding and PowerSTANDbY Power Connections Connection of Ranger 3 PhASE to Premises Wiring Figure A.1GENERAL DESCRIPTION Engine SWITChOperation Welder Controls Function and OperationRanger 3 PhASE Approximate Fuel Consumption Control DialStopping ThE Engine STARTING/ShUTDOWN InstructionsBREAK-IN Period Running PERIODS. Remove Loads and Allow Engine toStick Constant Current Welding Welding ProcessTypical Current Ranges 1 for Tungsten ELECTRODES2 SCRATCh Start TIG Constant Current WeldingProcess Used Mode Welding Wire Feed Welding Processes Constant VoltageElectrode Current Range Setting ARC GougingAccessories Optional Equipment Field InstalledStick WIRE FEEDRECOMMENDED EQUIPMENT TIGRoutine Maintenance MaintenanceSafety Precautions Engine OIL ChANGEAIR Cleaner and OThER Maintenance OIL Filter ChANGEEngine Adjustments Engine Maintenance PartsSlip Rings TROUbLEShOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionTROUbLEShOOTING Diagrams Diagrams Dimension Print M22327Ranger 3 PhASE Precaucion Warnung