Lincoln Electric CV-400-I manual Starting the Machine, Auxiliary Power, Overload Protection

Page 18

B-7

OPERATION

B-7

 

 

 

STARTING THE MACHINE

The power switch at the extreme right side of the con- trol panel energizes the CV-400-I.

ADJUSTING THE OUTPUT VOLTAGE USING THE DIGITAL METER

The digital meters in the CV-400-I incorporate a voltage pre- set function. This allows the operator to set the desired welding voltage before striking an arc. The digital meters can also display welding current.

To make use of the voltage preset function, the Volts/Amps switch must be in the "Volts" position. Turn the Voltage Adjust knob until the digital meter displays the desired weld- ing voltage. (See below if an external power source remote control is installed.)

When an arc is struck, the digital meter displays the actual welding voltage, as measured at the CV-400-I output termi- nals.

NOTE: The arc voltage at the electrode may be as much as two volts different from the CV-400-I output terminal voltage. This is due to voltage drops present in the welding cables, cable connections, and welding gun. To minimize these drops, use cables of ade- quate capacity, and make sure all connections are clean and tight. Because of these voltage drops, you may have to preset the CV-400-I for a slightly higher welding voltage than your procedure calls for.

To read welding current, set the Volts/Amps switch to the "Amps" position. The welding current will be displayed whenever an arc is struck.

LOCAL/REMOTE SWITCH OPERATION

If voltage control is desired at the CV-400-I, the Local/Remote switch must be in the "Local" position. The Voltage Adjust on the front panel can be used to adjust the CV-400-I output. (The remote control, even if connected, will have no effect if the switch is in the "Local" position).

To use a remote control, such as the K857 (see INSTALLA- TION section), place the Local/Remote switch (see Figure B.1) in the "Remote" position. The remote control now con- trols the output voltage, in the manner described above. This control may be adjusted while welding to change the CV-400-I output.

AUXILIARY POWER

42 volt AC auxiliary power, as required for some wire feeders, is available through the wire feeder recepta- cle. A 10 amp circuit breaker protects the 42 volt cir- cuit from overloads.

CV-400-I Export machines only can also supply 115 volt AC auxiliary power through the wire feeder recep- tacle. A 5 amp circuit breaker protects the 115 volt circuit from overloads.

The CV-400-I can supply 220 volt AC power at 2 amps for powering water coolers or other equipment. This auxiliary power is available from the Continental European type receptacle mounted on the case back. A 2 amp circuit breaker, located next to the recepta- cle, protects this auxiliary from overloads.

NOTE: Do not use circuits 2 or 4 for control of auxil- iary loads. (The 2-4 circuit is isolated from the 31-32 and 41-42 circuits.)

CAUTION

Note that some types of equipment, especially pumps and large motors, have starting currents which are significantly higher than their running current. These higher starting currents may cause the circuit breaker to open. If this situation occurs, the user should refrain from using the CV-400-I auxiliary power for that equip- ment.

___________________________________________

OVERLOAD PROTECTION

This welder has thermostatic protection from exces- sive duty cycles, overloads, loss of cooling, and high ambient temperatures. When the welder is subjected to an overload or loss of cooling, a thermostat will open. This condition will be indicated by the illumina- tion of the yellow Thermostatic Protection Light on the case front (see Figure B.1).The fan will continue to run to cool the power source. No welding is possible until the machine is allowed to cool and the Thermostatic Protection Light goes out.

CV-400-I

Image 18
Contents Idealarc CV-400-I Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-400-IInput Connections Safety PrecautionsSelect Suitable Location StackingField Installed Options Output ConnectionsParalleling Operation Operating InstructionsGeneral Warnings Power Source Operation Operational Features and ControlsDesign Features General DescriptionControls and Settings Thermal Protection Indication LightIndicates Warning Information Located on Right Case Side Voltage ControlC. Output Connectors Output Panel ConnectionsCase Back Connections VAC ReceptacleAuxiliary Power Starting the MachineOverload Protection Accessories Factory Installed OPTIONS/ACCESSORIESCompatible Lincoln Equipment Safety Precautions MaintenanceGeneral Maintenance Machine and Circuit Protection1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting BUILT-IN Diagnostic Routines and Error CodesError Code Trouble Remedy Machine Troubleshooting Guide ProblemsPossible Areas Recommended Symptoms Wire feeders For application Improper procedures Options Troubleshooting Guide ProblemsControl PC Board Meter PC BoardOutput Voltage Fault Protection OperationOptional K857 Remote Control Check Checking Snubber CircuitDiagrams Wiring Diagram CV 400-I ExportWiring Diagram CV 400-I Europe CV Power Source to AN LN-7 and K857 To Work K480 Input Cable Electrode CableCV Power Source to a K867 AdapterPower Source to a K867 / K775 / LN-7 CV/CV-I Power Source To AN LN-25Power Source to AN LN-25 / K444-1 Lincoln Power Source to AN LN-742 WireInstallation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Dimension PrintHow To Read Shop Drawings Precaucion Warnung