WARNING
Turn off input power to the Welding Power Source using the disconnect switch at the fuse box Before connecting the wire feeder.
POWER SOURCE
+ | - | |
|
14PIN AMPHENOL
K867 UNIVERSAL ADAPTER PLUG
ELECTRIC | Only qualified persons should install, use or |
| |
SHOCK | service this machine. |
| N.C. |
CAN KILL |
|
| |
| 81 | NOT USED ON | |
| 82 | ||
| SPARE |
|
|
| 2 | CONNECT TOGETHER FOR | |
| 4 | WELDING OUTPUT | N.D. |
| 41 | 42 VAC |
|
| 42 | N.E. | |
|
| ||
| 31 |
| |
| 115 VAC | N.F. | |
| 32 | ||
| POWER SOURCE FRAME CONNECTION | ||
| GND | ||
| 21 | WIRE FEEDER VOLTMETER CONNECTION |
CV POWER SOURCE TO A K867
DIAGRAMS
TO WORK | 77 | CONNECTS TO (WORK TERMINAL) OF POWER SOURCE | ||
10K |
| |||
ELECTRODE CABLE | 76 |
| REMOTE OUTPUT CONTROL | |
75 | MIN. | N.F. | ||
|
UNIVERSAL
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION RELAY TO CLOSE LEADS 2 & 4.
N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.
N.F. NOT PRESENT ON ALL MACHINES
{
TO 2
K867
4
TO WIRE FEEDER
S20658