Lincoln Electric CV-400-I manual Machine Troubleshooting Guide, Problems

Page 23

E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

MACHINE TROUBLESHOOTING GUIDE

Not all trouble conditions can be recognized by the PC board, and displayed as error codes. The following guide covers most other trouble conditions.

PROBLEMS

 

POSSIBLE AREAS OF

 

 

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENTS(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

PROBLEMS

 

 

 

 

 

 

 

Machine has no output.

1.

Secondary contactor circuit (2

1. Check 2 and 4 circuit wiring.

 

 

and 4 wire feeder receptacle) not

 

 

 

 

 

working.

 

 

 

 

2.

Electrode or work lead loose or

2.

Repair connection.

 

 

broken.

 

 

 

 

3.

Defective PC Board.

3.

See PC Board Troubleshooting

 

 

 

 

Procedure.

 

4.

Protective circuits operating due

4.

Turn power off. Remove output short

 

 

to output short circuit.

 

circuit.

 

5.

If using an LN-25, K484 jumper

5.

Check for continuity between pins C

 

 

plug kit not making connection

 

& D in the K484.

 

 

between 2 & 4 in wire feeder

 

 

 

 

 

receptacle.

 

 

 

 

6.

If welding with 1/16" aluminum

6.

a)

Turn power off to clear error. Use

 

 

wire and machine is flashing E00.

 

 

recommended wfs, voltage set-

 

 

 

 

 

tings and angle of approach of

 

 

 

 

 

wire to work.

 

 

 

 

b)

If problem still persists, call Local Lincoln

 

 

 

 

 

Authorized Field Service Facility.

 

 

 

 

 

Machine has minimum output and no

1.

Voltage Control misconnected.

1.

Voltage Control wiring.

control.

 

 

 

 

 

 

 

 

 

 

Machine has low output and no con-

1.

Open in feedback circuitry.

1.

Check wiring and control and PC

trol.

 

 

 

board wiring harness plugs.

 

2.

Faulty PC Board.

2.

See PC Board Troubleshooting

 

 

 

 

Procedure.

 

3.

Voltage Adjust potentiometer

3.

Check and replace potentiometer if

 

circuit open (lead 75).

 

faulty. Check wiring of lead #75.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CV-400-I

Image 23
Contents Idealarc CV-400-I California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Idealarc CV-400-I InstallationStacking Safety PrecautionsSelect Suitable Location Input ConnectionsOutput Connections Field Installed OptionsParalleling General Warnings OperationOperating Instructions General Description Operational Features and ControlsDesign Features Power Source OperationThermal Protection Indication Light Controls and SettingsVoltage Control Indicates Warning Information Located on Right Case SideOutput Panel Connections C. Output ConnectorsVAC Receptacle Case Back ConnectionsOverload Protection Auxiliary PowerStarting the Machine Compatible Lincoln Equipment AccessoriesFactory Installed OPTIONS/ACCESSORIES Machine and Circuit Protection MaintenanceGeneral Maintenance Safety PrecautionsHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Error Code Trouble Remedy TroubleshootingBUILT-IN Diagnostic Routines and Error Codes Problems Machine Troubleshooting GuidePossible Areas Recommended Symptoms Wire feeders For application Improper procedures Problems Options Troubleshooting GuideMeter PC Board Control PC BoardChecking Snubber Circuit Fault Protection OperationOptional K857 Remote Control Check Output VoltageWiring Diagram CV 400-I Export DiagramsWiring Diagram CV 400-I Europe To Work K480 Input Cable Electrode Cable CV Power Source to AN LN-7 and K857Adapter CV Power Source to a K867Power Source to a K867 / K775 / LN-7 To AN LN-25 CV/CV-I Power SourcePower Source to AN LN-25 / K444-1 Wire Lincoln Power Source to AN LN-742Installation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Print DimensionHow To Read Shop Drawings Precaucion Warnung