ii

 

SAFETY

 

ii

 

 

 

 

 

 

 

 

 

ELECTRIC SHOCK can kill.

3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free

gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.

In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:

Semiautomatic DC Constant Voltage (Wire) Welder.

DC Manual (Stick) Welder.

AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical (earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.

3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

ARC RAYS can burn.

4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.

4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.

FUMES AND GASES can be dangerous.

5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. When

welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.

5.b. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations.

The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products.

5.c. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.

5.d. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.

5.e. Also see item 1.b.

Mar ‘95

Image 3
Contents Idealarc CV-400-I California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Idealarc CV-400-I InstallationStacking Safety PrecautionsSelect Suitable Location Input ConnectionsOutput Connections Field Installed OptionsParalleling Operation Operating InstructionsGeneral Warnings General Description Operational Features and ControlsDesign Features Power Source OperationThermal Protection Indication Light Controls and SettingsVoltage Control Indicates Warning Information Located on Right Case SideOutput Panel Connections C. Output ConnectorsVAC Receptacle Case Back ConnectionsAuxiliary Power Starting the MachineOverload Protection Accessories Factory Installed OPTIONS/ACCESSORIESCompatible Lincoln Equipment Machine and Circuit Protection MaintenanceGeneral Maintenance Safety PrecautionsHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting BUILT-IN Diagnostic Routines and Error CodesError Code Trouble Remedy Problems Machine Troubleshooting GuidePossible Areas Recommended Symptoms Wire feeders For application Improper procedures Problems Options Troubleshooting GuideMeter PC Board Control PC BoardChecking Snubber Circuit Fault Protection OperationOptional K857 Remote Control Check Output VoltageWiring Diagram CV 400-I Export DiagramsWiring Diagram CV 400-I Europe To Work K480 Input Cable Electrode Cable CV Power Source to AN LN-7 and K857Adapter CV Power Source to a K867Power Source to a K867 / K775 / LN-7 To AN LN-25 CV/CV-I Power SourcePower Source to AN LN-25 / K444-1 Wire Lincoln Power Source to AN LN-742Installation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Print DimensionHow To Read Shop Drawings Precaucion Warnung