INSTALLATION | ||
|
|
|
TECHNICAL SPECIFICATIONS – IDEALARC CV-400-I
INPUT - THREE PHASE ONLY
Standard
Voltage
220/380/440/3/50/60
230/400/3/50/60
380/500/3/50/60
415/3/50/60
200/400/3/50/60
Duty Cycle
NEMA Class II (60)
100% Duty Cycle
IEC
100% Duty Cycle
Welding Current/Voltage Range
(Continuous)
50A/7V - 400A/37V
DC
Efficiency at 100% Load
NEMA Rated 78%, IEC Rated 68%
Idle Power
825W
Input Current at
Rated Output
100% Duty Cycle 60/35/30
60% Duty Cycle 62/36/31
100% Duty Cycle 58/34
60% Duty Cycle 60/33
100% Duty Cycle 35/26
60% Duty Cycle 36/27
100% Duty Cycle 32
60% Duty Cycle 33
100% Duty Cycle 66/33
60% Duty Cycle 68/34
RATED OUTPUT
Amps
400
300
400
300
OUTPUT
Normal Open Circuit Voltage
MAX OCV: 50
Input kVA
NEMA 60% Load - 23.6, IEC 60% Load - 23.2 NEMA 100% Load - 22.9, IEC 100% Load - 23.2
MISC. INFORMATION
Power Factor at Rated Load
.80
Power Factor at 100% Load
.55
Code
Number
10183 (Export, NEMA Rated)
10182 (European, IEC Rated)
10184 (Export, NEMA Rated)
10185 (Export, NEMA Rated)
10186 (Export, NEMA Rated)
Volts at Rated Amperes
36
32
34
29
Auxiliary Power
42 Volts AC, 10 Amps
115 Volts AC, 5 Amps (Except Code 10182)
220 Volts AC, 2 Amps
( All Circuit Breaker Protected)
Idle Current - Amps
16/9/8
PHYSICAL DIMENSIONS
Height | Width | Depth | Weight |
21.5 in. | 19.5 in. | 27.0 in. |
|
| (Lift bail, add 3.12 in) |
| 300 lbs |
|
|
| (137 kg) |
546 mm | 495 mm | 686 mm |
|
| (Lift bail, add 80 mm) |
|
|
|
|
|
|