Lincoln Electric manual Installation, Technical Specifications Idealarc CV-400-I

Page 8

A-1

INSTALLATION

A-1

 

 

 

TECHNICAL SPECIFICATIONS – IDEALARC CV-400-I

INPUT - THREE PHASE ONLY

Standard

Voltage

220/380/440/3/50/60

230/400/3/50/60

380/500/3/50/60

415/3/50/60

200/400/3/50/60

Duty Cycle

NEMA Class II (60)

100% Duty Cycle

IEC 974-1 60%

100% Duty Cycle

Welding Current/Voltage Range

(Continuous)

50A/7V - 400A/37V

DC

Efficiency at 100% Load

NEMA Rated 78%, IEC Rated 68%

Idle Power

825W

Input Current at

Rated Output

100% Duty Cycle 60/35/30

60% Duty Cycle 62/36/31

100% Duty Cycle 58/34

60% Duty Cycle 60/33

100% Duty Cycle 35/26

60% Duty Cycle 36/27

100% Duty Cycle 32

60% Duty Cycle 33

100% Duty Cycle 66/33

60% Duty Cycle 68/34

RATED OUTPUT

Amps

400

300

400

300

OUTPUT

Normal Open Circuit Voltage

10-43

MAX OCV: 50

Input kVA

NEMA 60% Load - 23.6, IEC 60% Load - 23.2 NEMA 100% Load - 22.9, IEC 100% Load - 23.2

MISC. INFORMATION

Power Factor at Rated Load

.80

Power Factor at 100% Load

.55

Code

Number

10183 (Export, NEMA Rated)

10182 (European, IEC Rated)

10184 (Export, NEMA Rated)

10185 (Export, NEMA Rated)

10186 (Export, NEMA Rated)

Volts at Rated Amperes

36

32

34

29

Auxiliary Power

42 Volts AC, 10 Amps

115 Volts AC, 5 Amps (Except Code 10182)

220 Volts AC, 2 Amps

( All Circuit Breaker Protected)

Idle Current - Amps

16/9/8

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

21.5 in.

19.5 in.

27.0 in.

 

 

(Lift bail, add 3.12 in)

 

300 lbs

 

 

 

(137 kg)

546 mm

495 mm

686 mm

 

 

(Lift bail, add 80 mm)

 

 

 

 

 

 

CV-400-I

Image 8
Contents Idealarc CV-400-I Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-400-ISafety Precautions Select Suitable LocationInput Connections StackingField Installed Options Output ConnectionsParalleling General Warnings OperationOperating Instructions Operational Features and Controls Design FeaturesPower Source Operation General DescriptionControls and Settings Thermal Protection Indication LightIndicates Warning Information Located on Right Case Side Voltage ControlC. Output Connectors Output Panel ConnectionsCase Back Connections VAC ReceptacleOverload Protection Auxiliary PowerStarting the Machine Compatible Lincoln Equipment AccessoriesFactory Installed OPTIONS/ACCESSORIES Maintenance General MaintenanceSafety Precautions Machine and Circuit Protection1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideError Code Trouble Remedy TroubleshootingBUILT-IN Diagnostic Routines and Error Codes Machine Troubleshooting Guide ProblemsPossible Areas Recommended Symptoms Wire feeders For application Improper procedures Options Troubleshooting Guide ProblemsControl PC Board Meter PC BoardFault Protection Operation Optional K857 Remote Control CheckOutput Voltage Checking Snubber CircuitDiagrams Wiring Diagram CV 400-I ExportWiring Diagram CV 400-I Europe CV Power Source to AN LN-7 and K857 To Work K480 Input Cable Electrode CableCV Power Source to a K867 AdapterPower Source to a K867 / K775 / LN-7 CV/CV-I Power Source To AN LN-25Power Source to AN LN-25 / K444-1 Lincoln Power Source to AN LN-742 WireInstallation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Dimension PrintHow To Read Shop Drawings Precaucion Warnung