Lincoln Electric CV-400-I Output Voltage, Fault Protection Operation, Checking Snubber Circuit

Page 28

E-8

TROUBLESHOOTING

E-8

 

 

 

OUTPUT VOLTAGE

The open circuit voltage of the machine should be 10 to 43 volts. If any other condition exists, refer to the Troubleshooting Guide.

FAULT PROTECTION OPERATION

The overload protection circuit on the PC Board will cause the CV-400-I meter to display "E60". This pro- tection circuit will reset itself automatically. The short circuit protection circuit will cause the meter to display "E00". The CV-400-I power switch must be turned "OFF" and then "ON" to return the machine to normal output.

CHECKING SNUBBER CIRCUIT

In case of an SCR malfunction or failure, the snubber assembly should be checked. Disconnect the input power to the CV-400-I at the fuse box and remove the right side of the machine.

1.Visually inspect the snubber PC Board assembly (located below the Control PC board on the case front for overheated components or damaged compo- nents).

OPTIONAL K857 REMOTE CONTROL

CHECK

Disconnect the remote output control and connect an ohm- meter between pins C and B and rotate the rheostat in the remote control. The resistance reading should go from zero to 10K ohms. Repeat with ohmmeter across A and B with the same results. Connect ohmmeter across A and C. The reading should be 10K ohms. A lower reading will indicate a shorted or partially shorted rheostat. A very high reading will indicate an open rheostat. In either of the last two cases, replace the rheostat.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CV-400-I

Image 28 Contents
Idealarc CV-400-I Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-400-ISafety Precautions Select Suitable LocationInput Connections StackingField Installed Options Output ConnectionsParalleling Operating Instructions OperationGeneral Warnings Operational Features and Controls Design FeaturesPower Source Operation General DescriptionControls and Settings Thermal Protection Indication LightIndicates Warning Information Located on Right Case Side Voltage ControlC. Output Connectors Output Panel ConnectionsCase Back Connections VAC ReceptacleStarting the Machine Auxiliary PowerOverload Protection Factory Installed OPTIONS/ACCESSORIES AccessoriesCompatible Lincoln Equipment Maintenance General MaintenanceSafety Precautions Machine and Circuit Protection1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideBUILT-IN Diagnostic Routines and Error Codes TroubleshootingError Code Trouble Remedy Machine Troubleshooting Guide ProblemsPossible Areas Recommended Symptoms Wire feeders For application Improper procedures Options Troubleshooting Guide ProblemsControl PC Board Meter PC BoardFault Protection Operation Optional K857 Remote Control CheckOutput Voltage Checking Snubber CircuitDiagrams Wiring Diagram CV 400-I ExportWiring Diagram CV 400-I Europe CV Power Source to AN LN-7 and K857 To Work K480 Input Cable Electrode CableCV Power Source to a K867 AdapterPower Source to a K867 / K775 / LN-7 CV/CV-I Power Source To AN LN-25Power Source to AN LN-25 / K444-1 Lincoln Power Source to AN LN-742 WireInstallation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Dimension PrintHow To Read Shop Drawings Precaucion Warnung
Related manuals
Manual 44 pages 36.61 Kb