Lincoln Electric IM602-A manual Safety, California Proposition 65 Warnings

Page 2

i

SAFETY

i

WARNING

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents are known to the State of California to cause can- cer, birth defects, and other reproductive harm.

The Above For Diesel Engines

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

The Above For Gasoline Engines

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes

outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame welding arc or when the engine is running.

Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz- ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety g u a r d s t o p e r f o r m r e q u i r e d m a i n t e n a n c e . R e m o v e guards only when necessary and replace them when the m a i n t e n a n c e r e q u i r i n g t h e i r r e m o v a l i s c o m p l e t e . Always use the greatest care when working near moving parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods

while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.

1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.

ELECTRIC AND MAGNETIC FIELDS may be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.

2.c. Exposure to EMF fields in welding may have other health effects which are now not known.

2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.

2.d.5. Do not work next to welding power source.

Mar ‘95

Image 2
Contents DC-655 Safety California Proposition 65 WarningsE C T R I C S H O C K c a n kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcVSAFETY ViSAFETY Thank You Table of Contents Height Width Depth Weight InstallationTechnical Specifications DC-655 Input Hertz Input Ampere Type 80CSmaw SAW Input Power Three PhaseGmaw Fcaw NRTL/C NrtlElectrical Input Connections Safety PrecautionsSelect Suitable Location Reconnect Procedure Input Power Supply ConnectionsTable A.1 Output ConnectionsElectrode and Work Cables LOW Inductance TerminalAuxiliary Power Control Connections Terminal Strips Terminal Strip 1 T.S.1Terminal Strip 2 T.S.2 General Warnings OperationGeneral Description Recommended Processes and EquipmentDesign Features and Advantages Welding CapabilityLOCAL/REMOTE Control Switch When this Controls and SettingsPower ON/OFF Switch This tog Output Terminals ON/REMOTE When thisFigure B.2 Lower Case Front Controls & Connections Machine Protection Welding Performance CC Mode ARC Gouging CV Mode CURRENT-LIMITINGCC Mode HOT Start CC Mode ARC ForceAutomatic Wire Feeders AccessoriesSEMI-AUTOMATIC Wire Feeders Field Installed OptionsAccessories Safety Precautions MaintenanceGeneral Maintenance Troubleshooting HOW to USE Troubleshooting GuideProblems Troubleshooting Trol circuit. #75, #76, #77 Problems Troubleshooting Troubleshooting Troubleshooting PC Board Troubleshooting Guide Firing P.C. Board PC Board Troubleshooting Guide Control P.C. Board10TROUBLESHOOTINGE-10 Diagrams Negative PositiveGND Negative Positive Receptacle Convenience, this extended #21 lead should be taped to 655 Wiring Diagram for Codes 10501,10503, 10504 Diagrams Diagrams Diagrams Diagrams Aviso DE Keep your head out of fumes Turn power off before servicing