AUXILIARY POWER

The RANGER 8+ DIESEL can provide up to 9,000 watts of 115/230 volts AC, Single phase 60 HZ power for continuous use. The front of the machine includes three receptacles for connecting AC power Plugs, one

50amp 115/230 volt NEMA 14-50R receptacle and two 15 amp 115 volt NEMA 5-15R receptacles. Do not connect any plugs that connect to the power receptacles in parallel.

Start the engine and set the "IDLER" control switch to the desired operating mode. Set the "CONTROL" to

10.Voltage is now correct at the receptacles for auxil- iary power.

Most 1.5 hp AC single phase motors can be started if there is no load on the motor or other load connected to the machine. Larger motors through 2 hp can be run provided the receptacle rating as previously stated

is not exceeded. This may necessitate 230 volt oper- ation only.

SIMULTANEOUS WELDING AND POWER LOADS

Auxiliary power ratings are with no welding load. Simultaneous welding and power loads are permitted by the following table. The permissible currents shown assume that current is being drawn from either the 115 volt or 230 volt supply (not both at the same time).

RANGER 8+ DIESEL SIMULTANEOUS WELDING AND POWER LOADS

(OUTPUT CONTROL SET AT 10)

TABLE B.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

Welding

 

 

Permissible

 

 

Permissible

 

 

 

Permissible

 

 

 

Selector

 

 

 

Output

 

 

Power Watts

 

 

Auxiliary Current in

 

 

 

Auxiliary Current

 

 

 

Setting

 

 

 

Amps

 

 

(Unity Power

 

 

Amperes @ 115V

 

 

 

in Amperes @

 

 

 

 

 

 

 

 

 

 

 

Factor)

 

 

 

 

 

 

230V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

225 DC / 250 AC

 

 

 

 

 

 

 

 

0

 

 

MAX

 

 

 

NONE

0

 

 

 

 

 

 

175

 

 

175

 

 

 

2100

 

 

20

 

 

10

 

 

 

125

 

 

125

 

 

 

3800

 

 

32

 

 

16

 

 

 

90

 

 

90

 

 

 

5000

 

 

42

 

 

21

 

 

 

70

 

 

70

 

 

 

5600

 

 

46

 

 

23

 

 

 

50

 

 

50

 

 

 

6300

 

 

52

 

 

26

 

 

 

NO WELDING

 

 

 

 

 

 

 

9000

 

 

80

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Voltage and permissible watts decrease as "CONTROL" is adjusted to settings less than 10. It is recommended that at settings less than 10, only incandescent lighting loads be connected to the auxiliary power receptacles.

RANGER 8+ DIESEL

Image 24
Contents Ranger 8 + Diesel Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcEngine Service Thank YouTable of Contents Vii Installation Technical Specifications Ranger 8+ Diesel K1632-1Installation Instructions PRE-OPERATION Engine Service Additional Safety PrecautionsLifting OILBattery Connections FuelSpark Arrester Electrical Connections Total Combined Length of Electrode and Work CablesMachine Grounding Welding Cable ConnectionsAuxiliary Power RECEPTACLES, PLUGS, and HAND-HELD Equipment Premises WiringCircuit Breakers Connection of Ranger 8+ Diesel to Premises Wiring Figure A.1Design Features Other FeaturesAuxiliary Power OperationAdditional Safety Precautions Diesel EngineLimitations Recommended ApplicationsControls and Settings Figure B.1 Output Panel Controls Machine ControlsOperation Engine Operation Before Starting the EngineStarting the Engine Stopping the EngineBREAK-IN Period Table B.1 Typical Ranger 8+ Diesel Fuel ConsumptionWelding Operation Wire Feed Welding Processes Constant Voltage Welding ProcessStick Constant Current Welding TIG Constant Current WeldingSummary of Welding Processes Auxiliary Power Simultaneous Welding and Power LoadsTable B.4 115/230 Volt Dual Voltage Receptacle Figure B.3 115V Duplex ReceptaclesAccessories General Options AccessoriesTIG Welding Options Accessories Semiautomatic Fcaw and MIG Welding Options / Acces Sories Accessories Connection Diagrams Connection of Ranger 8+ Diesel to LN-7 & K240 Contactor KITMaintenance Safety PrecautionsRoutine Maintenance Engine Adjustments BatteryEngine Maintenance Components Slip RingsTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Engine will not go to high idle Poor work lead connection to Troubleshooting Diagrams Maximum Overall Dimensions Ranger 8+ How To Read Shop Drawings Precaucion Warnung