TROUBLESHOOTING AND REPAIR | ||
|
|
|
TROUBLESHOOTING GUIDE
Observe all Safety Guidelines detailed throughout this manual.
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |||
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
|
|
| |
Major Physical or Electrical Damage | 1. Contact your local Lincoln | 1. | Contact | The Lincoln Electric | |
is Evident |
| Electric Authorized Field Service |
| Service Dept. | |
|
| Facility. |
|
|
|
|
|
|
| ||
|
|
| 1. Check input power switch (S1). | ||
Machine is dead — no open circuit | 1. | Make certain that the input |
| It may be faulty. | |
voltage output and no wire feed |
| power switch is in the "ON" posi- |
|
|
|
when gun trigger is pulled. The |
| tion. | 2. Check for lose or broken wires | ||
machine display may be lit. |
|
|
| at the reconnect panel. | |
| 2. Check the input voltage at the |
|
|
| |
|
| machine. Input voltage must | 3. | Perform | Main Transformer |
|
| match the rating plate and the |
| Test. |
|
|
| reconnect panel. |
|
|
|
|
|
| 4. Perform Rectifier Diode Bridge | ||
| 3. | Blown or missing fuses in the |
| Test. |
|
|
| input line. |
|
|
|
|
|
| 5. Check | the thermostats and | |
| 4. | The thermostats may be open |
| associated leads for loose or | |
|
| due to machine overheating. If |
| broken connections. See wiring | |
|
| machine operates normally after |
| diagram. | |
|
| a cooling off period then check |
|
|
|
|
| for proper fan operation and | 6. The control board may be faulty. | ||
|
| ventilation. Make certain that the |
| Replace. | |
|
| machine's duty cycle is not |
|
|
|
|
| being exceeded. |
|
|
|
| 5. Check the trigger circuit. Leads |
|
|
| |
|
| #324 to #325 should have conti- |
|
|
|
|
| nuity (zero ohms) when the gun |
|
|
|
|
| trigger is pulled. If not then the |
|
|
|
|
| gun may be faulty — replace. |
|
|
|
| 6. Make sure the machine is not |
|
|
| |
|
| connected to a portable genera- |
|
|
|
|
| tor. |
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call