A-5

INSTALLATION

A-5

LOCATION / VENTILATION

The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet. Also, locate the welder so that engine exhaust fumes are properly vented to an outside area.

STACKING

RANGER 10,000 machines cannot be stacked.

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

WARNING

Shut off welder before making any electrical connections.

------------------------------------------------------------------------

WIRE FEED (CONSTANT VOLTAGE) CONNECTION OF LN-15 ACROSS-THE-ARC WIRE FEEDER

The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

a.Shut the welder off.

b.Connect the electrode cable from the LN-15 to the“ELECTRODE” terminal of the welder. Connect the work cable to the “TO WORK” terminal of the welder.

c.Set the Polarity switch to the desired polarity, either DC (-) or DC (+).

d.Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

e.Set the “RANGE” switch to the “WIRE FEED-CV” position

f.Place the Engine switch in the “High Idle” position.

g.Adjust the wire feed speed at the LN-15 and adjust the welding voltage with the output “CONTROL” at the welder. Output “CONTROL” must be set above 3.

Note: LN-15 Control Cable model will not work with the RANGER 10,000.

CONNECTION OF THE LN-25 TO THE RANGER

10,000

d.Position the “RANGE” switch to the “WIRE FEED” position.

e.Attach the single lead from the LN-25 control box to the work using the spring clip on the end of the lead - it carries no welding current.

f.Place the engine switch in the “AUTO” position.

g.Adjust wire feed speed at the LN-25 and adjust the welding voltage with the output “CONTROL” at the welder.

NOTE: The welding electrode is energized at all times, unless an LN-25 with built-in contactor is used. If the output “CONTROL” is set below “3”, the LN-25 contactor may not pull in.

CONNECTION OF K930-2 TIG MODULE TO THE RANGER 10,000.

The TIG Module is an accessory that provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding. See IM528 supplied with the TIG Module for installation instructions.

Note: The TIG Module does not require the use of a high frequency bypass capacitor. However, if the RANGER 10,000 is used with any other high frequen- cy equipment, the bypass capacitor must be installed, order kit T12246.

INSTRUCTIONS

ADDITIONAL SAFETY PRECAUTIONS

Always operate the welder with the roof and case sides in place as this provides maximum protection from moving parts and assures proper cooling air flow.

Read and understand all Safety Precautions before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Owner’s Manual.

WELDER OPERATION

WELDER OUTPUT

Maximum Open Circuit Voltage at 3700 RPM is 80 Volts RMS.

Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example, a 60% duty cycle represents 6 minutes of load and 4 minutes of no load in a 10 minute period. Duty Cycle for the RANGER 10,000 is 100%.

a.Shut the welder off.

b.Connect the electrode cable from the LN-25 to the“ELECTRODE” terminal of the welder. Connect the work cable to the “TO WORK” termi- nal of the welder.

c.Position the welder “Polarity” switch to the desired polarity, either DC (-) or DC (+).

RANGER 10,000

Constant Current

225 Amps AC @ 25 Volts

 

 

210 Amps DC @ 25 Volts

 

 

 

 

Constant Voltage

200 Amps DC @ 20 Volts

 

 

 

 

RANGER 10,000

Image 12
Contents Ranger 10,000 Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Installation Height Width Depth WeightSafety Precautions Vehicle Mounting FuelOIL AWG FallingConnection of the LN-25 to the Ranger Connection of K930-2 TIG Module to the Ranger 10,000Welder Output 120/240 Volt Dual Voltage Receptacle Duplex ReceptaclesMotor Starting Electrical Device USE with the Ranger 10,000 These Devices Without Additional Resistive Type LoadsNot USE These Devices With a Ranger 10,000 Auxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections Installation Connection of Ranger 10,000 to Premises WiringSafety Precautions Engine SwitchOperation Polarity Switch Range SwitchRanger 10,000 Approximate Fuel Consumption Control DialSTARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineWire Feed Welding Processes Constant Voltage Welding ProcessStick Constant Current Welding TIG Constant Current WeldingStick Auto Accessories K1745-1 GAS Cylinder HolderWire Feed StickTIG Welding Plasma CuttingMaintenance Engine OIL ChangeEngine OIL Refill Capacities Kohler HondaAIR Cleaner and Other Maintenance OIL Filter ChangeEngine Adjustments BatteryOverspeed is Hazardous Slip RingsTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Diagrams Ranger 10,000 Kohler CSA Wiring Diagram forRanger 10,000 Honda Wiring Diagram for Code M20431 Engine Welder Kohler , Honda and Robin / Subaru Precaucion Warnung