Lincoln Electric IM819-B manual Operation, Safety Precautions, Engine Switch

Page 17

B-1

OPERATION

B-1

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have thoroughly read the engine manufacturers manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

Always operate the welder with the hinged door closed and the side panels in place.

Read carefully the Safety Precautions page before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Instruction Manual.

------------------------------------------------------------------------

GENERAL DESCRIPTION

The Ranger10,000 is a twin-cylinder, gasoline dri- ven, multiprocess arc welder and AC power genera- tor. It is built in a heavy gauge steel case for durability on the job site.

WELDER CONTROLS - FUNCTION AND OPERATION

ENGINE SWITCH

The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine.

When placed in the OFF position, the ignition circuit is de-energized to shut down the engine.

When held in the START position, the engine starter motor is energized.

When in HIGH IDLE( ) position, the engine will run continuously at high idle.

When in AUTO IDLE( / ) position, the engine will run continuously and the idler operates as follows:

Welding

When the electrode touches the work, the welding arc is initiated and the engine accelerates to full speed.

After welding ceases (and no auxiliary power is being drawn), the engine will return to low idle after approximately 10 to 14 seconds.

Auxiliary Power

With the engine running at low idle and auxiliary power for lights or tools is drawn (approximately 100-150 watts or greater) from the receptacles, the engine will accelerate to high speed. If no power is being drawn from the receptacles (and not welding) for 10-14 seconds, the idler reduces the engine speed to low idle.

RANGER 10,000

Image 17
Contents Ranger 10,000 Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Height Width Depth Weight InstallationSafety Precautions OIL Vehicle MountingFuel Falling AWGWelder Output Connection of the LN-25 to the RangerConnection of K930-2 TIG Module to the Ranger 10,000 Motor Starting 120/240 Volt Dual Voltage ReceptacleDuplex Receptacles Not USE These Devices With a Ranger 10,000 Electrical Device USE with the Ranger 10,000These Devices Without Additional Resistive Type Loads Standby Power Connections Auxiliary Power While WeldingSimultaneous Welding and Power Connection of Ranger 10,000 to Premises Wiring InstallationOperation Safety PrecautionsEngine Switch Range Switch Polarity SwitchRanger 10,000 Approximate Fuel Consumption Control DialBREAK-IN Period STARTING/SHUTDOWN InstructionsStarting the Engine Stopping the EngineWelding Process Wire Feed Welding Processes Constant VoltageStick Constant Current Welding TIG Constant Current WeldingStick Auto K1745-1 GAS Cylinder Holder AccessoriesStick Wire FeedTIG Welding Plasma CuttingEngine OIL Change MaintenanceEngine OIL Refill Capacities Kohler HondaOIL Filter Change AIR Cleaner and Other MaintenanceBattery Engine AdjustmentsOverspeed is Hazardous Slip RingsHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Ranger 10,000 Kohler CSA Wiring Diagram for DiagramsRanger 10,000 Honda Wiring Diagram for Code M20431 Engine Welder Kohler , Honda and Robin / Subaru Precaucion Warnung