Lincoln Electric IM819-B manual Maintenance, Engine OIL Change, Engine OIL Refill Capacities

Page 24

D-1

MAINTENANCE

D-1

SAFETY PRECAUTIONS

WARNING

Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the mainte- nance requiring their removal is complete. Always use the greatest care when working near moving parts.

Do not put your hands near the engine cooling blower fan. If a problem cannot be corrected by following the instructions, take the machine to the nearest Lincoln Field Service Shop.

-----------------------------------------------------------------------

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.

Use in open, well ventilated areas

or vent exhaust outside.

------------------------------------------------------------------------

MOVING PARTS can injure.

Do not operate with doors open or guards off.

Stop engine before servicing.

Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information throughout this operators manual and the Engine manual as well.

------------------------------------------------------------

Read the Safety Precautions in the front of this manual and the engine instruction manual before working on this machine.

Keep all equipment safety guards, covers, and devices in position and in good repair. Keep hands, hair, cloth- ing, and tools away from gears, fans, and all other moving parts when starting, operating, or repairing the equipment.

Routine Maintenance

At the end of each days use, refill the fuel tank to minimize moisture condensation in the tank. Running out of fuel tends to draw dirt into the fuel system. Also, check the crankcase oil level and add oil if indicated.

CAUTION

Make certain that the oil filler cap is securely tight- ened after checking or adding oil. If the cap is not tight, oil consumption can increase significantly which may be evidenced by white smoke coming from the exhaust.

OIL - Maintenance schedule for changing the oil and oil filter after break-in :

 

KOHLER

HONDA

ROBIN / SUBARU

 

CH20S

GX620KI

EH64

 

 

6 Months

 

Oil

100 HRS.

100 HRS.

100 HRS.

 

 

1 Year or

 

Oil Filter

200 HRS.

200 HRS.

200 HRS.

 

 

 

 

The above schedule is for normal operating condi- tions. More frequent oil changes are required with dusty, high temperature and other severe operating conditions. Refer to the maintenance section of the Engine Owner's Manual for more information.

NOTE: Engine life will be reduced if the oil and oil filter are not changed according to the manufacturers recommendation.

ENGINE OIL CHANGE

Drain the oil while the engine is warm to assure rapid and complete draining.

Remove the oil filler cap and dipstick. Remove the yellow cap from the oil drain valve and attach the flexible drain tube supplied with the machine. Push in and twist the drain valve counterclockwise. Pull the valve out and drain the oil into a suitable contain- er.

Close the drain valve by pushing in and twisting clockwise. Replace the yellow cap.

Refill to the upper limit mark on the dipstick with the recommended oil. Tighten the oil filler cap securely.

ENGINE OIL REFILL CAPACITIES

Without oil filter replacement:

1.7 US qt. (1.4 Imp qt., 1.6 liter)-Kohler

1.6 US qt. (1.3 IMP qt., 1.5 liter)-Honda GX620KI

1.5 US qt. (1.2 IMP qt., 1.4 liter)-Robin / Subaru

With oil filter replacement:

2.0 US qt. (1.7 Imp qt., 1.9 liter)-Kohler

1.9 US qt. (1.6 Imp qt. , 1.8 liter)-Honda GX620KI

1.6 US qt. (1.4 IMP qt., 1.6 liter)-Robin / Subaru

RANGER 10,000

Image 24
Contents Ranger 10,000 Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Installation Height Width Depth WeightSafety Precautions Vehicle Mounting FuelOIL AWG FallingConnection of the LN-25 to the Ranger Connection of K930-2 TIG Module to the Ranger 10,000Welder Output 120/240 Volt Dual Voltage Receptacle Duplex ReceptaclesMotor Starting Electrical Device USE with the Ranger 10,000 These Devices Without Additional Resistive Type LoadsNot USE These Devices With a Ranger 10,000 Auxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections Installation Connection of Ranger 10,000 to Premises WiringSafety Precautions Engine SwitchOperation Polarity Switch Range SwitchRanger 10,000 Approximate Fuel Consumption Control DialSTARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineWire Feed Welding Processes Constant Voltage Welding ProcessStick Constant Current Welding TIG Constant Current WeldingStick Auto Accessories K1745-1 GAS Cylinder HolderWire Feed StickTIG Welding Plasma CuttingMaintenance Engine OIL ChangeEngine OIL Refill Capacities Kohler HondaAIR Cleaner and Other Maintenance OIL Filter ChangeEngine Adjustments BatteryOverspeed is Hazardous Slip RingsTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Diagrams Ranger 10,000 Kohler CSA Wiring Diagram forRanger 10,000 Honda Wiring Diagram for Code M20431 Engine Welder Kohler , Honda and Robin / Subaru Precaucion Warnung