MAINTENANCE

D-2

Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SG or SH. Always check the API SERVICE label on the oil con- tainer to be sure it includes the letters SG or SH.

SAE 10W-30 is recommended for general, all-tempera- ture use, -5 F to 104 F (-20 C to 40 C).

See Engine Owners Manual for more specific informa- tion on oil viscosity recommendations.

Wash your hands with soap and water after handling used oil.

Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you take it in a sealed container to your local service station or recycling center for reclamation.

Do not throw it in the trash, pour it on the ground or down a drain.

OIL FILTER CHANGE

1.Drain the engine oil.

2.Remove the oil filter, and drain the oil into a suitable container. Discard the used oil filter.

3.Clean the filter mounting base, and coat the gasket of the new oil filter with clean engine oil.

4.Screw on the new oil filter by hand, until the gasket contacts the filter mounting base, then use an oil fil- ter socket tool to tighten the filter an additional 1/2 to 7/8 turn.

5.Refill the crankcase with the specified amount of the recommended oil. Reinstall the oil filler cap.

6.Start the engine and check for oil filter leaks.

7.Stop the engine, and check the oil level. If neces- sary, add oil to the upper limit mark on the dipstick.

AIR CLEANER AND OTHER MAINTENANCE

Air Cleaner - With normal operating conditions, the maintenance schedule for cleaning and re-oiling the foam pre-filter is every 25 hours and replace- ment of the air cleaner filter every 100 hours. More frequent servicing is required with dusty operating conditions. Refer to the maintenance section of the Engine Owners Manual for more information.

Refer to the maintenance section of the Engine Owners Manual for the maintenance schedule, spark plug servicing, cooling system servicing, and fuel filter replacement.

Blow out the machine with low pressure air period- ically. In particularly dirty locations, this may be required once a week.

Output Ranger Selector and Polarity Switches: Switch contacts should not be greased. To keep contacts clean, rotate the switch through its entire range frequently. Good practice is to turn the han- dle from maximum to minimum setting twice each morning before starting to weld.

RANGER 10,000

Image 25
Contents Ranger 10,000 Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Height Width Depth Weight InstallationSafety Precautions Fuel Vehicle MountingOIL Falling AWGConnection of K930-2 TIG Module to the Ranger 10,000 Connection of the LN-25 to the RangerWelder Output Duplex Receptacles 120/240 Volt Dual Voltage ReceptacleMotor Starting These Devices Without Additional Resistive Type Loads Electrical Device USE with the Ranger 10,000Not USE These Devices With a Ranger 10,000 Simultaneous Welding and Power Auxiliary Power While WeldingStandby Power Connections Connection of Ranger 10,000 to Premises Wiring InstallationEngine Switch Safety PrecautionsOperation Range Switch Polarity SwitchRanger 10,000 Approximate Fuel Consumption Control DialBREAK-IN Period STARTING/SHUTDOWN InstructionsStarting the Engine Stopping the EngineWelding Process Wire Feed Welding Processes Constant VoltageStick Constant Current Welding TIG Constant Current WeldingStick Auto K1745-1 GAS Cylinder Holder AccessoriesStick Wire FeedTIG Welding Plasma CuttingEngine OIL Change MaintenanceEngine OIL Refill Capacities Kohler HondaOIL Filter Change AIR Cleaner and Other MaintenanceBattery Engine AdjustmentsOverspeed is Hazardous Slip RingsHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Ranger 10,000 Kohler CSA Wiring Diagram for DiagramsRanger 10,000 Honda Wiring Diagram for Code M20431 Engine Welder Kohler , Honda and Robin / Subaru Precaucion Warnung