OPERATION

B-1

 

 

 

OPERATING INSTRUCTIONS

Safety Precautions

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

Duty Cycle

The Synergic 7 models are rated at 60% duty cycle * for

2-STEP

STD

4-STEP

LOCK

SPOT

Mode Selection

Mode Select key ( behind “drop- door” cover) enables operator to choose mode of operation shown by the indicator lights. Pressing key causes mode lights to sequence (top to bottom) starting from the current indicated position.

Top Light - Indicates 2-Step (Standard) Trigger Mode.

1.Trigger closure energizes the solenoid valve, then the wire feeder and the power source after Preflow time (See Timer/ Crater Section).

2.Releasing the trigger turns off the wire feeder and power source and then the solenoid valve after Postflow time.

Middle Light - Indicates 4-Step (Lock) Trigger Mode. These models have selectable 4-step with crater fill or, as shipped, 4-step with current interlock. (See 4-step trigger mode selection for method of switching).

The 4-step modes function as follows:

a maximum current of 600 amps.

* Based on a 10 minute time period (6 minutes on, and 4 minutes off).

KEYPAD SETUP AND OPERATION

Power-Down Save

Power to the Synergic 7 is supplied and controlled from the power source. The Synergic 7 automatically senses the loss of power when the power source is turned off.

Procedure settings, including mode, crater speed, cold feed speed , run-in speed, weld speed, timers and acceleration are automatically saved when power is removed. Arc Voltage setting is retained by the synergic power source. This feature does not require batteries and when power is restored it will automati- cally return all settings to the state they were in when power was removed. The power source may auto- matically overwrite any or all of these settings follow- ing power-up recall.

Operation Keys

Cold Feed key energizes the wire

feeder but not the power source or solenoid valve. This cold feed speed is digitally displayed and is

COLD FEED adjustable (with “Arrow keys”) only while pressing the Cold Feed Key.

The last setting is held in memory for next Cold feeding.

Gas Purge key energizes the sole- noid valve but not the wire feeder or

GAS PURGE power source.

1.Trigger closure energizes the power source and wire feeder after the pre- flow time.

2.Trigger release enables 4-step lock, leaving the feeder and power source as in step 1.

a)4-step with current interlock will only lock if weld current is flowing. Breaking weld arc stops wire feed and power source output.

b)4-step with crater fill will lock without welding.

3.Closing the trigger a second time continues welding.

a)4-step with current interlock contin- ues welding without changing the settings from step 2.

b)4-step with crater fill continues weld- ing but changes to the crater set- tings.

4.Releasing the trigger turns off wire feeder and power source and then gas solenoid after postflow time.

Bottom Light - Indicates Spot Weld Mode. Trigger closure energizes the solenoid valve, then wire feeder and the power source. The spot on timer starts when current flows. The wire feeder and power source then sole- noid valve are all turned off when the spot on timer times out even through the trigger is still closed.

SYNERGIC 7 & 7H

Image 19
Contents Synergic 7 and 7H Mar ‘95 SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionMar. ‘93 Précautions DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Size & Weight Without Wire Stand With K377 Wire Stand InstallationTechnical Specifications Synergic 7 and 7H Type K631-3 K631-4 Wire Speed RangeRecommended Processes and Equipment Standard FeaturesWire Drive Features General DescriptionControl Features RUN-IN WFS Y P a D a N D D I S P L a Y DescriptionElectric Shock can kill Safety PrecautionsAluminum Wire Sizes Procedure to Install Drive Roll and Guide TubesWire Feed Drive Roll and Guide Tube Kits Steel Wire Sizes RollGmaw Guns Gun Cable Connection Wire Feeder to GunGun and Cable Assemblies For GMA Gun CablesCylinder may explode if damaged Shut off shielding gas supply when not in useSynergic 7 Water Connections for Water- Cooled Guns Gmaw Shielding GasElectrical Installation Warning 60% Duty Cycle Up to 100 ft Length 30m Optional Features InstallationWork Cable CurrentInstallation Operating Instructions Mode SelectionPower-Down Save OperationDisplay Control Keys Preset voltage/trim may be adjustedCold Feed Memory Ammeter Selection Step Trigger Mode SelectionDual Procedure Remote Control K1449-1 Procedure Selector SwitchFigure B.1a Threaded Locking Collar Wire LoadingInnershield Coils Coil tie wires To remove the wire reel from its shaft, graspKnob so it seats into the shaft when released Cut the tie wires at this timeREADI-REELS a K438 READI-REEL Adapter Must be Used Feeding ElectrodeGas Guard Regulator Setting Idle Roll Pressure SettingWire Feed Overload Protection Wire Reel ChangingMaking a Weld Grounding Lead Protector Explanation of Prompting Error MessagesOptional Features Accessories60 LB .2 KG Coil Adapter K1504-1 Universal Wire Reel Stand K1524-1READI-REEL Adapters K179 type vacuum unit not recommended for use with Synergic MISC. OptionsRoutine Maintenance MaintenanceMaintenance Avoiding Wire Feeding ProblemsLocate Problem Symptom 1TROUBLESHOOTINGE-1Troubleshooting Replace WeldingIng and gas flow rate is proper IngConnector J1 on control PC No control of wire feedTers on wire feeder display do not Defective wire feed motor tach orOr there may be a problem with Wire feed motor runs and solenoid Power source is defectiveWiring harness or Control PC Speed does not change when Run-in and weld speeds are setRemote control kit must be used Meters on wire feeder display doNot match those on power Problem with wire feeder harnessTroubleshooting Wiring harness, or Control board Dure switch Be connectedBetween procedures a and B Display. If not, refer to ProblemFaulty communication between Local dual procedure switchDual procedure switch is used to Switch between procedures aTroubleshooting HXX Procedure for Replacing PC Boards Electric Shock can kill Wiring Diagram Synergic DiagramsElectric Shock Can Kill Input Connection DiagramW I R E R E E L S T a N D Dimension PrintSynergic 7 & 7H Synergic 7 & 7H Synergic 7 & 7H Synergic 7 & 7H Precaucion Warnung