TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
7. No control of wire feed. | a. Problem with serial communications. | a. If WFS and preset Volts/Trim parame- |
|
| ters on wire feeder display do not |
|
| match those on power source display, |
|
| see Problem 14. |
| b. Defective wire feed motor tach or | b. Measure voltage across pin 2 (+) of J3 |
| control PC Board. | and pin 3 |
|
| motor running. If voltage is |
|
| then replace control PC board (see |
|
| Procedure for Replacing PC Boards). |
|
| If not, then replace tachometer. |
8. No wire feed, solenoid, or arc volt- a. Faulty gun or gun trigger switch. | a. Remove gun. Check continuity |
age. LED display indicated | between trigger pins with trigger |
Synergic 7 has input power. | closed. If no continuity repair or |
| replace gun. |
b. Defective control PC board or | b. Remove gun. Check voltage across |
gun connector. | trigger sockets on gun connector. |
| If voltage > ± 11 VDC then gun is |
| defective. |
| If voltage is < ± 11 VDC then check |
| the voltage across pin 2 (+) and pin 8 |
|
|
| board. |
| If the voltage is still < ± 11 VDC then |
| replace control PC board. (See |
| Procedure for replacing PC boards). |
| Otherwise, either the gun connector or |
| wiring harness is faulty. |
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
SYNERGIC 7 & 7H