TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
12. Arrow keys do not change Weld | a. This is normal, as only the WFS and | a. Refer to operation section of this manual |
speed or volts/trim. | volts/trim knobs will adjust these settings. |
|
|
|
|
13. WFS knob does not change | a. This is normal, as only the arrow | a. Refer to operation section of this manual. |
keys will adjust this setting. |
| |
|
|
|
14. WFS and preset Volts/Trim para- | a. Power source is defective. | a. If parameters on power source and wire |
meters on wire feeder display do |
| feeder display match when wire feeder is |
not match those on power |
| connected to the other input receptacle (#1 |
source display. |
| or #2) of power source then power source |
|
| is defective. |
| b. Problem with serial communica- | b. Disconnect input cable from power source |
| tions in control cable. | and wire feeder. Check continuity between |
|
| socket G of |
|
| pin plug of the input cable. Check continu- |
|
| ity between socket H of |
|
| pin H of |
|
| Replace cable if no continuity. |
| c. Problem with wire feeder harness | c. Remove molex plug P1 from J1 on Control |
| or Control PCB. | PCB. Check continuity from pin G of |
|
| receptacle on wire feeder to pin 4 of plug |
|
| P1, and from pin H of |
|
| pin 3 of plug P1. If no continuity then repair |
|
| harness, otherwise replace Control PCB. |
|
| (See procedure for replacing PC boards.) |
|
|
|
15. Display does not change when | a. A remote control kit is connected. | a. When a remote control kit is connected to |
WFS and/or Volts/Trim knobs |
| the Wire Feeder, the WFS and Volts/Trim |
are turned. |
| knobs of the Wire Feeder become inactive |
|
| and the WFS and Volts/Trim knobs of the |
|
| remote control kit must be used. |
| b. Broken harness wire(s) or harness | b. Check for continuity between correspond- |
| disconnected from Encoder | ing harness leads of molex plug P2 on |
| board(s) or Control board. | Control board and molex plugs P12 and |
|
| P13 on Encoder boards (refer to wiring dia- |
|
| gram). If any of these continuity tests fail, |
|
| repair or replace harness. |
| c. Defective Encoder boards and/or | c. If b. is not the problem and neither the WFS |
| Control board. | or Volts/Trim knobs are properly adjusting |
|
| then replace the Control board. If one of |
|
| the knobs is properly adjusting, plug the |
|
| harness, P12 or P13, from the working |
|
| board into the nonfunctional board. If the |
|
| previously nonfunctional board is now work- |
|
| ing then replace the Control board, other- |
|
| wise replace the nonfunctional Encoder |
|
| board. (See procedure for replacing PC |
|
| boards.) |
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
SYNERGIC 7 & 7H