INSTALLATION | ||
|
|
|
Wire Feed Drive Roll and Guide Tube Kits
NOTE: The maximum sizes the Synergic 7 will feed satisfactorily are the 3/32” (2.4mm) cored and 1/16” (1.6mm) solid electrodes. The maximum sizes the Synergic 7H will feed satisfactorily are the .045 (1.2mm) cored and .045” (1.2mm) solid electrodes.
The electrode sizes that can be fed with each roll and guide tube are stencilled on each part. Check the kit for proper components.
Steel Wire Sizes: |
| |
* | .068 - 3/32” (1.7 - 2.4mm) Cored | |
* | 1/16” (1.6mm) Cored or Solid | |
| .045 | |
| .045 | |
| .035” | |
| .035” | |
| .030” (0.8mm) Solid | |
| .023” (0.6mm) Solid | |
Aluminum Wire Sizes: |
| |
| 1/16” (1.6mm) | |
|
| |
| 3/64” (1.2mm) | |
|
| |
| .040” (1.0mm) | |
| .035” (0.9mm) |
Drive rolls for only cored electrode sizes are stencilled with a “C” suffix to the wire sizes.
Drive rolls for only solid electrode sizes are stencilled with an “S” suffix to the wire sizes.
Drive rolls for aluminum wire sizes are stencilled with an “A” suffix to the wire sizes.
* Not for Synergic 7H model.
**For use with Binzel European guns. Installation instructions are included with these kits. Also requires
PROCEDURE TO INSTALL DRIVE ROLL AND GUIDE TUBES
WARNING
ELECTRIC SHOCK can kill.
•Do not touch electrically live parts such as output terminals or internal wiring.
•When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.
•Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.
•Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.
•Only qualified personnel should perform this installation.
Observe all additional Safety Guidelines detailed throughout this manual.
Standard 4-Roll Kits (KS655 and KS656)
1)Turn OFF welding power source.
2)Release both quick release levers by sliding the levers sideways into the open positions.
3)Remove clamping screw & clamping collar from the drive shaft closest to the incoming side of the feed- er.
4)Install drive roll onto keyed shaft. (Do not exceed the maximum wire size rating of the wire drive.) Replace collar and tighten clamping screw.
5)Back out the set screw for the middle guide tube. Install the middle guide tube and slide it up against the drive roll. DO NOT TIGHTEN THE MIDDLE GUIDE AT THIS TIME.
6)Install the outgoing drive roll following the same procedure as steps 3 & 4.
7)Center the middle guide between the two drive rolls and tighten in place.