TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
9. Wire feed motor runs and solenoid | a. Power source is defective. | a. If arc voltage is present when wire feeder is | ||
| turns on but no arc voltage pre- |
| connected to the other input receptacle (#1 or | |
| sent. |
| #2) of power source then power source is | |
|
|
| defective. Otherwise, select a stick procedure | |
|
|
| on power source, connect a known good input | |
|
|
| cable (see step b) to wire feeder #1 receptacle | |
|
|
| of power source, and jumper across sockets C | |
|
|
| and D of | |
|
|
| voltage is present (refer to display on power | |
|
|
| source) then power source is defective. | |
|
| b. Input cable is defective. | b. Disconnect input cable from power source and | |
|
|
| wire feeder. Check continuity between socket | |
|
|
| C of | |
|
|
| the input cable, and between socket D of 8- | |
|
|
| socket plug and pin D of | |
|
|
| input cable. Replace cable if no continuity. | |
|
| c. Wiring harness or Control PC | c. Check continuity between pin C of | |
|
| board is defective. | tacle and pin 7 of plug P1, and between pin D | |
|
|
| of | |
|
|
| continuity then harness is faulty, otherwise | |
|
|
| replace Control PC board. (See procedure for | |
|
|
| replacing PC boards.) | |
|
|
|
|
|
10. Speed does not change when | a. | a. Set | ||
| weld current flows. | to the same value or | tings. | |
|
| to |
|
|
|
| b. Power Source may be defective | b. Make sure that parameters on power source | |
|
| or there may be a problem with | display, such as WFS, match those on wire | |
|
| the Serial communications. | feeder display. If not, refer to Problem 14. | |
|
|
| Otherwise, replace control PC board. (See | |
|
|
| procedure for replacing PC boards.) | |
|
|
|
| |
11. Voltmeter does not function or | a. Electrode sensing lead or connec- | a. Check continuity from brass block on wire | ||
| read properly when arc voltage is | tions may be intermittent. | feeder to pin F of | |
| present. |
| cle on wire feeder. If there is no continuity, | |
|
|
| repair faulty connection. | |
|
| b. Serial communication problem. | b. Make sure that parameters on power source | |
|
|
| display, such as WFS, match those on wire | |
|
|
| feeder display. If not, refer to Problem 14. | |
|
|
| Otherwise, replace Control PC board. (See | |
|
|
| procedure for replacing PC boards.) | |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
SYNERGIC 7 & 7H