A-5

INSTALLATION

A-5

 

 

 

MUFFLER

Remove the plastic plug covering the muffler outlet tube. Using the clamp provided secure the extension to the outlet tube. This welder is supplied with an adjustable rain cap for the muffler. Install the rain cap using the clamp provided with the outlet facing away from the direction in which this unit will be transported. This will minimize the amount of water and debris which could enter the muffler during transportation.

SPARK ARRESTER

Some federal, state or local laws may require that gasoline or diesel engines be equipped with exhaust spark arresters when they are operated in certain loca- tions where unarrested sparks may present a fire haz- ard. The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, a suitable spark arrester, such as the S24647 must be installed and properly maintained.

CAUTION

An incorrect arrester may lead to damage to the engine or adversely affect performance.

------------------------------------------------------------------------

HIGH FREQUENCY GENERATORS FOR TIG APPLICATIONS

The K799 Hi-Freq Unit and the K930-1 or-2 TIG Module are suitable for use with the Commander 300. The Commander 300 is equipped with the required R.F. bypass circuitry for the connection of high fre- quency generating equipment. The high frequency bypass network supplied with the K799 Hi-Freq Unit does NOT need to be installed into the Commander 300.

The Commander 300 and any high frequency generat- ing equipment must be properly grounded. See the K799 Hi-Freq Unit and the K930-1 or-2 TIG Module operating manuals for complete instructions on instal- lation, operation, and maintenance.

REMOTE CONTROL

OUTPUT

The Commander 300 is equipped with a 6 pin & 14-pin connector. The 6 pin connector is for connecting the K857 or K857-1 Remote Control (Optional) or in the case of TIG welding applications, with the foot or hand Amptrol. (K870 or K812 respectively).

The 14 pin connector is used to directly connect a wire feeder or TIG Module (K930-1 or-2) control cable. When remote output control is used, the output control toggle switch is to be set at “Remote.”

NOTE: When using the 14 pin connector, if the wire feeder has a built in power source output control, do not connect anything to the 6 pin connector.

WELDING TERMINALS

The Commander is equipped with a toggle switch for selecting "hot" welding terminals when in the "WELD- ING TERMINALS ALWAYS ON" position or "cold" welding terminals when in the "WELDING TERMI- NALS REMOTELY CONTROLLED" position.

COMMANDER 300

Image 13
Contents Commander Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Vii Installation Safety Precautions Lifting PRE-OPERATION Engine Service High Frequency Generators for TIG Applications Welding Output Cables Power Connection of the LN-25 to the Commander Connection of Lincoln Electric Wire FeedersConnection of LN-7 or LN-8 to the Commander CommanderConnection of AN LN-23P Wire Feeder to the Commander Design Features and Advantages Safety InstructionsOperating Instructions General DescriptionOther Features For Auxiliary PowerK1585-1 Commander 300 Standard Model Welding CapabilityRUN- Stop Switch Controls and SettingsStart Pushbutton Fuel Level Gauge and LightOIL Pressure Gauge K1585-2 Std., K1585-1 Opt. and Light Idler SwitchIdler Operational exceptions Hour MeterAuxiliary Power Controls Starting the Engine Engine OperationStopping the Engine BREAK-IN Period Welder OperationTypical Fuel Consumption Stick WeldingCommander 300 Settings When Using the K930-1 TIG Module Commander 300 Settings When Using the K799 HI-FREQ UnitTable B.3 Typical Current Ranges 1 for Tungsten ELECTRODES2 Wire Feed Constant Voltage Weld ING Simultaneous Welding and AUXIL- Iary Power Loads Auxiliary Power OperationRecommended Optional EQUIP- Ment Optional Field Installed AccessoriesRoutine and Periodic Maintenance Safety PrecautionsEngine Maintenance Cooling System Cooling Blower Belt Fuel FiltersWelder / Generator Maintenance Nameplates / Warning Decals MaintenanceMake Part Number HOW to USE Troubleshooting Guide TroubleshootingPossible Areas SymptomsCourse of Action Function Problems Output Problems Wiring DiagramWiring DiagramCommander 300-STANDARD Model Wiring Diagram Code 10469 only Connection Diagram Connection Connection S23988 S23989 Installation Instructions Connection S23992 S24787-3 S23994 Commander 300 / K930 TIG Module / Connection Diagram $!#% 300 Dimension PrintCommander Commander $700.00 Basic CoursePrecaucion Aviso DE