INSTALLATION

A-8

 

 

 

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

WARNING

Shut off welder before making any electrical connec- tions.

------------------------------------------------------------------------

CONNECTION OF THE LN-25 TO THE COMMANDER 300

The LN-25 with or without an external contactor may be used with the Commander 300. See the appropri- ate connection diagram in the ACCESSORIES section.

NOTE: The LN-25 (K431) Remote Control Module and (K432) Remote Cable are not recommended for use with the Commander 300.

a.Shut the welder off.

b.For electrode Positive, connect the electrode cable from the LN-25 to the “+” terminal of the welder and work cable to the “-” terminal of the welder. For electrode Negative, connect the electrode cable from the LN-25 to the “-” terminal of the welder and work cable to the “+” terminal of the welder.

c.Attach the single lead from the front of the LN-25 to work using the spring clip at the end of the lead. This is a sense lead to supply current to the wire feeder motor; it does not carry welding current.

d.Set the SELECTOR switch to the “WIRE WELD- ING” position.

e.Set the “WELDING TERMINALS” switch to “WELD-

ING TERMINALS ALWAYS ON”

f.Adjust the “ARC CONTROL” knob to desired crisp- ness. Generally, welding is best if the “ARC CON- TROL” is set to SOFT for MIG and CRISP for Innershield.

g.Set the “IDLE” switch to the “AUTO” position. When not welding, the Commander 300 engine will be at the low idle speed. If you are using an LN-25 with an internal contactor, the electrode is not energized until the gun trigger is closed.

CAUTION

If you are using an LN-25 without an internal contactor, the electrode will be energized when the Commander 300 is started.

------------------------------------------------------------------------

h.When the gun trigger is closed, the current sensing circuit will cause the Commander 300 engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.

CONNECTION OF LN-7 OR LN-8 TO THE COMMANDER 300

a.Shut the welder off.

b.Connect the LN-7 or LN-8 per instructions on the appropriate connection diagram in Section 4.

c.Set the “LOCAL /REMOTE” switch to “REMOTE” for the LN-8 or LN-7 with a K857 (or K857-1) remote voltage control cable attached; “LOCAL” for LN-7 with no remote voltage control.

d.Set the “WIRE FEEDER VOLTMETER” switch to either “+” or “-” as required by the electrode being used.

e.Set the “SELECTOR” switch to the “WIRE WELD- ING” position.

f.Adjust the “ARC CONTROL” knob to desired Crispness. SOFT for MIG - CRISP for Innershield.

g.Set the “WELDING TERMINALS” switch to the

“WELDING TERMINALS” REMOTELY CON- TROLLED” position.

h.Set the “IDLE” switch to the “HIGH” position. When not welding, the Commander 300 engine will be at the low idle speed.

COMMANDER 300

Image 16
Contents Commander Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Vii Installation Safety Precautions Lifting PRE-OPERATION Engine Service High Frequency Generators for TIG Applications Welding Output Cables Power Connection of Lincoln Electric Wire Feeders Connection of the LN-25 to the CommanderConnection of LN-7 or LN-8 to the Commander CommanderConnection of AN LN-23P Wire Feeder to the Commander Safety Instructions Design Features and AdvantagesOperating Instructions General DescriptionFor Auxiliary Power Other FeaturesK1585-1 Commander 300 Standard Model Welding CapabilityControls and Settings RUN- Stop SwitchStart Pushbutton Fuel Level Gauge and LightIdler Switch OIL Pressure Gauge K1585-2 Std., K1585-1 Opt. and LightIdler Operational exceptions Hour MeterAuxiliary Power Controls Starting the Engine Engine OperationStopping the Engine Welder Operation BREAK-IN PeriodTypical Fuel Consumption Stick WeldingCommander 300 Settings When Using the K930-1 TIG Module Commander 300 Settings When Using the K799 HI-FREQ UnitTable B.3 Typical Current Ranges 1 for Tungsten ELECTRODES2 Wire Feed Constant Voltage Weld ING Auxiliary Power Operation Simultaneous Welding and AUXIL- Iary Power LoadsOptional Field Installed Accessories Recommended Optional EQUIP- MentRoutine and Periodic Maintenance Safety PrecautionsEngine Maintenance Fuel Filters Cooling System Cooling Blower BeltNameplates / Warning Decals Maintenance Welder / Generator MaintenanceMake Part Number Troubleshooting HOW to USE Troubleshooting GuidePossible Areas SymptomsCourse of Action Function Problems Output Problems Diagram WiringDiagram WiringCommander 300-STANDARD Model Wiring Diagram Code 10469 only Connection Diagram Connection Connection S23988 S23989 Installation Instructions Connection S23992 S24787-3 S23994 Commander 300 / K930 TIG Module / Connection Diagram $!#% Dimension Print 300Commander Commander Basic Course $700.00Precaucion Aviso DE