C-1

ACCESSORIES

C-1

 

 

 

OPTIONAL FIELD INSTALLED ACCESSORIES

K802R POWER PLUG KIT - Provides a plug for each receptacle. Use K802N for code numbers above 10500.

K802N POWER PLUG KIT - Provides four 120V plugs.

K857 28 ft. (8.5 m) or K857-1 100 ft. (30.4 m) REMOTE CONTROL - Portable control provides same dial range as the output control on the welder from a location up to the specified length from the welder. Has convenient plug for easy connection to the welder. The Commander 300 is equipped with a 6 pin connector for connecting the remote control and a toggle switch for selecting “LOCAL” output con- trol or “REMOTE” output control.

K704 ACCESSORY SET - Includes 35 feet (10 m) of electrode cable and 30 feet (9 m) of work cable, head- shield, work clamp and electrode holder. Cable is rated at 500 amps, 60% duty cycle.

K953-1 TWO WHEEL TRAILER - For road, in-plant and yard towing. Road towing with optional fender & light kit. (For highway use, consult applicable federal, state and local laws regarding possible additional requirements)

K953-1 TrailerK958-1 Ball Hitch

K958-2 Lunette Eye Hitch K959-1 Fender & Light Kit K965-1 Cable Storage Rack

K887-1 ETHER START KIT - Provides maximum cold weather starting assistance for frequent starting below 10 oF (-12.2 oC). Required Ether tank is not provided with kit.

S24647 SPARK ARRESTOR KIT - Easily mounts to standard muffler. Approved by U.S.D.A. Forest Service.

K1604-1 OIL DRAIN KIT - Includes ball valve, hose and clamp.

K1690-1 (1 Duplex) GFCI Kit - Includes one UL approved 115V ground fault circuit interrupter duplex type receptacle with cover and installation instructions. Replaces the factory installed 115V duplex receptacle. The receptacle of the GFCI duplex is rated at 20 amps, the maximum total current from the GFCI duplex is lim- ited to 20 amps. Two kits are required.

K1596-1 Dual Output Meters and Gauges - Dual out- put meters provide preset ability of voltage for wire welding and current for stick welding. Measures b o t h current and voltage when welding. Gauges include: battery ammeter, engine temperature, and engine oil pressure. Fuel gauge is not available in kit form.

K1597-1 42vac Transformer Kit. - For products requir- ing 42 VAC power source.

RECOMMENDED OPTIONAL EQUIP- MENT

STICK

K704 Accessory Kit which includes:

Electrode holder and cable.

Ground clamp and cable.

Headshield.

K857 Remote Control Kit is optional for remote cur- rent control.

TIG

Magnum TIG Torch

Magnum Parts Kit and Argon gas

K930-ALL TIG Module (not required for scratch start DC TIG welding)

K936-1 Control Cable

K870 Foot Amptrol

Also available:

K963-1/-2 Hand Amptrol

K814 Arc Start Switch

K937-22 Control Cable Extension

K937-45 Control Cable Extension

K844-1 Water Valve

WIRE FEED WELDING

LN-25

LN-7

LN-23P

LN-8

NA-3 • Spool Gun & K488 Module

LN-742 (requires optional K1597-1 42vac trans- former kit).

HIGH FREQUENCY GENERATORS FOR TIG APPLICATIONS

The K799 Hi-Freq Unit and the K930-ALL TIG Modules are suitable for use with the Commander 300. The Commander is equipped with the required R.F. bypass circuitry for the connection of high frequency generat- ing equipment. The high frequency bypass network supplied with the K799 Hi-Freq Unit does NOT need to be installed into the Commander.

The Commander and any high frequency generating equipment must be properly grounded. See the K799 Hi-Freq Unit and the K930-All TIG Module operating manuals for complete instructions on installation, oper- ation, and maintenance.

COMMANDER 300

Image 28
Contents Commander Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Vii Installation Safety Precautions Lifting PRE-OPERATION Engine Service High Frequency Generators for TIG Applications Welding Output Cables Power Connection of Lincoln Electric Wire Feeders Connection of the LN-25 to the CommanderConnection of LN-7 or LN-8 to the Commander CommanderConnection of AN LN-23P Wire Feeder to the Commander Safety Instructions Design Features and AdvantagesOperating Instructions General DescriptionFor Auxiliary Power Other FeaturesK1585-1 Commander 300 Standard Model Welding CapabilityControls and Settings RUN- Stop SwitchStart Pushbutton Fuel Level Gauge and LightIdler Switch OIL Pressure Gauge K1585-2 Std., K1585-1 Opt. and LightIdler Operational exceptions Hour MeterAuxiliary Power Controls Starting the Engine Engine OperationStopping the Engine Welder Operation BREAK-IN PeriodTypical Fuel Consumption Stick WeldingCommander 300 Settings When Using the K930-1 TIG Module Commander 300 Settings When Using the K799 HI-FREQ UnitTable B.3 Typical Current Ranges 1 for Tungsten ELECTRODES2 Wire Feed Constant Voltage Weld ING Auxiliary Power Operation Simultaneous Welding and AUXIL- Iary Power LoadsOptional Field Installed Accessories Recommended Optional EQUIP- MentRoutine and Periodic Maintenance Safety PrecautionsEngine Maintenance Fuel Filters Cooling System Cooling Blower BeltNameplates / Warning Decals Maintenance Welder / Generator MaintenanceMake Part Number Troubleshooting HOW to USE Troubleshooting GuidePossible Areas SymptomsCourse of Action Function Problems Output Problems Diagram WiringDiagram WiringCommander 300-STANDARD Model Wiring Diagram Code 10469 only Connection Diagram Connection Connection S23988 S23989 Installation Instructions Connection S23992 S24787-3 S23994 Commander 300 / K930 TIG Module / Connection Diagram $!#% Dimension Print 300Commander Commander Basic Course $700.00Precaucion Aviso DE