TROUBLESHOOTING

TROUBLESHOOTING GUIDE

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

OUTPUT PROBLEMS

 

Machine has no output – no fans –

1. Check for proper input voltage

 

no display. Main input fuses are

connections.

 

open, indicating excessive input

2. Make certain the reconnect

 

current draw.

 

panel is configured properly for the

 

 

 

 

applied voltage.

 

 

3. Replace the input fuses with

 

 

proper size and ratings. If the

 

 

fuses fail again, contact your local

 

 

Lincoln Authorized Field Service

 

 

Facility.

If all recommended possible areas

 

 

 

 

of misadjustments have been

 

 

checked and the problem per-

Machine has no output – no dis-

 

sists, contact your local Lincoln

play – fans run.

1. Check circuit breaker (5-amp)

Authorized Field Service Facility.

 

located on the front panel. Reset if

 

 

necessary.

 

Machine has no output – no dis-

1. Remove the feeder control cable

play – fans run – circuit breaker

from the machine. If symptoms

(5-amp) repeatedly trips.

disappear, feeder or control cable

 

 

is faulty.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 450

Image 43
Contents Safety Depends on You Invertec Power WavetmFumes and Gases can be dangerous SafetyElectric Shock can kill ARC Rays can burnCylinder may explode if damaged Welding Sparks can cause fire or explosionFor Electrically pow- ered equipment Electric and Magnetic Fields For Engine powered equipmentMay be dangerous Précautions DE Sûreté Please Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Technical Specifications Power Wave InstallationPulse Pulse and Background Current Range Voltage Range Select Suitable Location Safety PrecautionsHigh Frequency Precautions Input ConnectionsGround Connections Input Voltage Reconnect ProcedureInput Power Connections Input Fuse and Supply Wire ConsiderationsWater Cooler Connections Wire Feeder ConnectionsOutput Connections Work and Electrode Cable ConnectionsFumes and Gases can be Safety InstructionsOperation Operating InstructionsSave process information if desired Select your process informationRecommended Processes Design Features and AdvantagesOperational Features and Controls Synergic WeldingCase Front Controls Controls and SettingsOperating Overlays Installing AN OverlayOverview Overlay Overlay TypesName Overlay ID Number = PULSE, GMAW, FCAW, and STICK/TIG Process Selection OverlayOperation Then Memory Location # is Empty Weld from Memory OverlayFigure B.6 Weld from MEMORY, Dual Procedure Overlay Weld from MEMORY, Dual Procedure OverlayOperation Position Procedure Dual Wire FEEDERS, Dual Procedure Overlay OptionalRecall from Memory KEY Memory Location Numbers Limits Overlay OptionalOperation Figure B.9 Setup Overlay Setup OverlayNegative Polarity Voltage Sensing Wire Feeder Setup DescriptionPositive Polarity Voltage Sensing Table B.1 Positive Voltage Sensing OptionsPositive Voltage Sensing Polarity STICK/TIG Procedures Overview of Welding ProceduresFlux Cored ARC Welding Fcaw and Gmaw Procedures Pulse ProceduresExplanation of Table B.3 Pulse processes Pulse WeldingThermal Protection Overload ProtectionOver Current Protection Guns and Cables AccessoriesOPTIONS/ACCESSORIES Wire Feeder SetupWater Cooler Usage Routine and Periodic Maintenance MaintenanceInput Filter Capacitor DIS Charge Procedure Figure D.1 Resistor Locations Locate the #9 and #12 terminals, identified by Discharge labels, on each of the four SwitchPreventive Maintenance Figure D.4 General Component Locations HOW to USE Troubleshooting Guide TroubleshootingAuthorized Field Service Facility Troubleshooting GuideSists, contact your local Lincoln Play fans run Check circuit breaker 5-amp Observe Safety Guidelines Controls and Settings Power-up Inspect the overlay bar code Saved in memory are different Check for proper shielding gas Wiring Diagram Wiring DiagramsNew Lessons in Arc Welding How To Read Shop DrawingsNeed Welding Training? Precaucion Aviso DE Limited Warranty